Battery Management Software Manual
44Pages

{{requestButtons}}

Catalog excerpts

Battery Management Software Manual - 1

Battery Management System Software Manual

Open the catalog to page 1
Battery Management Software Manual - 4

1. Software Overview BMS Battery Management Software allows for remote viewing and data management of all connected BMS battery monitoring systems. Report generation, trending analysis, & detailed alarming can all be viewed on a single or multiple PC’s on the same network. Use a network cable or RS232/RS485 cable connect between the computer and control module and setup the IP address to the device. Alternatively, the BMS can be configured to communicate via Modbus to a building management system, SCADA, or other custom fit management system. All control module include one output relay for...

Open the catalog to page 4
Battery Management Software Manual - 5

Picture 1 b. Double Click the ‘BMS.exe’ application to run, it will pop up a new window as Picture 2, there have three program to run, ‘Service’, ‘Collector’ and ‘Manager’. 3.1 Setup Service a. Click and run Service program. Picture 3 b. When it prompt error message as below, please click ‘Enter’ to creat and setup the

Open the catalog to page 5
Battery Management Software Manual - 6

Picture 4 c. There have dual redundant data storage, either in a second memory card or an external dual redundant hard drive to store, kindly find Picture 5 ‘Data File save path’ and ‘backup path’ are for the dual redundant data storage paths. The ‘backup path’ is optional, If you are not required for dual redundant data storage, kindly leave the backup path blank. ① Click ‘Browse’ to select the data storage path,click ‘Make New folder’ and rename the folder to data storage, click ’OK’ to finish,kindly find Picture 6. ② Selected ‘√’ to ‘create a new DB on the data server’, ③ Click ‘Save’ to...

Open the catalog to page 6
Battery Management Software Manual - 7

Picture 7 d. Enter to the server address setting interface, default IP: 127.0.0.1 is local host loopback address, default Server port is 4001, click ‘Start’ to run. Picture 8 Kindly pay attention to the prompt message to check if the system run successfully. If the left end of the window appears ’Running’, it means the database runs successfully. Kindly click to close this window, the small icon of Service program will locate at the right end of the taskbar from the desktop. If failed, please click ‘setting’ and in accordance with the prompt message to set up a new database, repeat the...

Open the catalog to page 7
Battery Management Software Manual - 8

3.2 Setup Manager Go back to the three application window, Click and run Manager program 3.2.1 Setup the enterprise information At the first time running the program, it will prompt to input the ‘Server Address’ and ‘Server Port’, please input the same Server Address and Server Port as section 3.1, and click ‘Save’ to finish. Picture 11 a. Type the original user name and password, and click Logi

Open the catalog to page 8
Battery Management Software Manual - 9

Original User Name: admin Original Password: 123456 Picture 12 b. Click ‘More’ Menu from top right corner of the window, select ‘Basic Setting’ to enter the site info setting interface.

Open the catalog to page 9
Battery Management Software Manual - 10

Picture 14 c. Click Enterprise Information menu, Click Modify and input your company information.Click Save to finish.

Open the catalog to page 10
Battery Management Software Manual - 11

3.2.2 Setup the site info a. Click Site Information menu, Click ‘Add’ to input the Site Info. Picture 16 b. Click ‘Save’ after input the site info, click Modify and Del to modify or delete the selected site info, please click Save to finish. If there have multiple sites, kindly Click ‘Add’ and input the site repeatedly.

Open the catalog to page 11
Battery Management Software Manual - 12

3.2.3 Setup the device info a. Select ‘device information’ from Basic Setting menu, please select the site and Click ‘Add’ to add the device.

Open the catalog to page 12
Battery Management Software Manual - 13

b. click Save to finish, if there have multiple device(UPS) at the site, kindly Click Add to input the device info. Picture 20 Kindly check the following description of device info Related Site: Select the site need to add device info. Device Address: Input Modbus Address of the related Control Module. (Please check the Modbus address from system configuration menu of Control Module) Communication Mode: Select ‘LAN Port’ or ‘Serial Port’ Device NO.: Input the device number of the control module Battery QTY: Input the total battery number of current UPS Network Address: Input the IP address...

Open the catalog to page 13
Battery Management Software Manual - 14

d. There have two ways to add the battery description, 1) Add the battery describe one by one. 2) Batch processing for all battery describe by Fill format, input ‘Bank No. [StringNumber], Battery No. [BatteryNumber]’ to Fill format, click ‘Fill’ to add the info, click ‘Save’ to finish. Kindly check the picture below,

Open the catalog to page 14
Battery Management Software Manual - 15

3.3 Setup Collector Go back to the three application window, Click and run Collector program Picture 23 a. At the first time running the program, it will prompt to input the ‘Server Address’ and ‘Server Port’, please input the same Server Address and Server Port as Section 3.1, and click ‘Save’ to finish. Picture 24 b. Type in original User Name and Password to login to the collecting interface. Original User Name: admin Original Password: 123456 Picture 25 c. Select the site name and related device, setting the collect interval range from 1000 MS to 5000 MS, click ‘Start’ to start...

Open the catalog to page 15
Battery Management Software Manual - 16

Picture 26 d. If prompt the message ‘Connections for a period of time didn’t response or No response from control module’ and ‘The initialization of internet communication was failed’ as below picture, it means the connection fail, please check and confirm control module is power on, and check the set up device info of ‘device address’, ’IP address’ and the ‘internet Port’ if correct. 4. Active Data Viewing 4.1 Real Time Monitoring a. Click the window of manager program, click ‘Monitoring’ at the left top corner‘, and click and select the device from ‘Device List’ to view the

Open the catalog to page 16
Battery Management Software Manual - 17

Picture 28 Kindly check the description from the main interface 1) Group info: the battery group information display window 2) Collect Time: present time collecting the data 3) Audio Alarm: enable to audio alarm when select it. 4) Device List: select the device from device list to view active data, right click the selected device for select Start Collect, Stop Collect or Collect interval setting. 5) Active Data: active display the battery voltage, internal resistance, temperature value and string and etc. 6) Graphs: green graphs show normal, red show abnormal. b. Click and select the device...

Open the catalog to page 17

All Shenzhen Relat Electronic Technology CO. catalogs and technical brochures