PS-VOC-E Air Quality Module

PS-VOC-E Air Quality Module

PS-VOC-E Air Quality Module

Product catalog summary
Brief Introduction: The PS-VOC-E air quality module utilizes fuel cell technology to convert VOC content into PPM values. It features high stability, good consistency, long service life, and requires no baseline correction or periodic calibration. It is pre-calibrated and ready for integration.
Key Features and Applications: The module is suitable for air cleaners, air conditioners, indoor air quality monitoring, portable devices, and smart homes. It boasts strong anti-poisoning ability and does not require periodic calibration.
Definition of Pins: The module has four pins: Vin (5V), GND, RXD (data input), and TXD (data output).
Technical Specifications: The PS-VOC-E model detects indoor air quality with a range of 0-5ppm and an overload capacity of 10ppm. It operates on 4.5-7V, with a warm-up time of less than 3 minutes, a response time of less than 90 seconds, and a recovery time of less than 120 seconds. It has a resolution of 0.001ppm, operates in temperatures from -40℃ to 70℃, and humidity from 10% to 90% RH. The module has a lifetime of 5 years and a warranty period of 12 months.
Communication Protocol: The module uses serial communication with a baud rate of 9600, 8 data bits, 1 stop bit, and no parity bit. It supports active upload and Q&A communication types, with commands for switching modes and reading gas concentration.
Checksum Calibration: A function is provided for checksum calibration to ensure data integrity.
Notes: Users should avoid altering the sensor or electronic components, and protect the module from organic vapors, solvents, high gas concentrations, excessive vibration, and shock.
Contact Information: ProSense Technologies Co., Ltd. is located in Shenzhen, China. Contact details include phone numbers and an email address for sales inquiries.
See more

Catalog excerpts

PS-VOC-E Air Quality Module-1

PS-VOC-E Air Quality Module Operation Manual

 Open the catalog to page 1
PS-VOC-E Air Quality Module-2

PS-VOC-E Air Quality Module Brief Introduction PS-VOC-E air quality module, works on the proven fuel cell technology, combines solid electrolyte with noble metal catalyst, converting VOC content into PPM directly. Once VOC arrives at working electrode (anode) it is oxidized instantaneously to generate an electrical signal. The electrical signal is then acquired and processed by microprocessor into a PPM value and is output by standard digital signal. PS-VOC-E is pre-calibrated in the factory and can be integrated into your system directly. Key Features High stability Good consistency Long service...

 Open the catalog to page 2
PS-VOC-E Air Quality Module-3

PS-VOC-E Air Quality Module Technical Specification MODEL Module makes use of serial communication. Communication configuration parameters are:

 Open the catalog to page 3
PS-VOC-E Air Quality Module-4

6 PS-VOC-E Air Quality Module Baud rate

 Open the catalog to page 4
PS-VOC-E Air Quality Module-5

PS-VOC-E Air Quality Module PS-VOC-E Air Quality Module Gas concentration = concentration (high byte)*256 + concentration (low byte) ‘Function name: unsigned char FucCheckSum(uchar*i,ucharln) ‘Function description: checksum calibration[Take Not(Byte1+Byte2+...Byte7) +1] > Avoid changing or moving sensor on the module. > Avoid moving or changing electronic elements on PCB. > Avoid exposure to organic vapour, organic solvents high gas concentration. > Protect from excessive vibration and shock. Add: Building4, Lianjian S&T Park, LonghuaDistrict,Shenzhen,China; Tel: +86 755 3669 0079 Mobile: +8613510916915...

 Open the catalog to page 5