PS-H2-20000 Hydrogen Module

PS-H2-20000 Hydrogen Module

PS-H2-20000 Hydrogen Module

Product catalog summary
Brief Introduction
The PS-H2-20000 hydrogen module by ProSense Technologies Co., Ltd. utilizes fuel cell technology to convert hydrogen content into PPM. It oxidizes hydrogen at the anode to generate an electrical signal proportional to hydrogen concentration, which is processed into a PPM value. The module is pre-calibrated and ready for integration.

Typical Applications and Key Features
Applications include factories, charging stations, warehouses for Li batteries, energy storage systems, and electrical vehicles. Key features are low power consumption, high stability, precision, fast response, long service life, and anti-poisoning.

Technical Specification
  • Model: PS-H2-20000
  • Detection Principle: Fuel Cell
  • Detectable Gas: H2
  • Detection Range: 0-20000ppm
  • Overload: 50000ppm
  • Input Voltage: 4.5-7V
  • Response Time (T90): <60S
  • Accuracy: ±4% FS (25±3℃)
  • Detection Limit: 30ppm
  • Repeatability: 3%
  • Operating Temperature: -40℃ to 70℃
  • Operating Pressure: 1atm±10%
  • Operating Humidity: 10%-90% RH (non-condensing)
  • Lifetime: 10 years
  • Warranty: 12 months
  • Weight: 4g
  • Poisoned by Silicone: None

Communication Protocol
The module uses serial communication with a baud rate of 9600, 8 data bits, 1 stop bit, and no parity bit. It supports active upload and Q&A communication types, with commands for switching modes and reading gas concentration.

Notes
Avoid altering the sensor or electronic elements on the PCB, and protect the module from organic vapors, solvents, high gas concentrations, excessive vibration, and shock.

Contact Information
Address: Building 4, Lianjian S&T Park, Longhua District, Shenzhen, China
Tel: +86 755 3669 0079
Website: www.szprosense.com
Email: [email protected]
See more

Catalog excerpts

PS-H2-20000 Hydrogen Module-2

PS-H2-20000 hydrogen module, works on the proven fuel cell technology, combines fuel cell technology with precise electronic technique, converting the hydrogen content into PPM directly. Once hydrogen arrives at working electrode (anode) it is oxidized instantaneously to generate an electrical signal which is proportional to the hydrogen concentration. The electrical signal is then acquired and processed by microprocessor into a PPM value and is output by standard digital signal. PS-H2-20000 is pre-calibrated in the factory and can be integrated into your system directly. Typical Applications...

 Open the catalog to page 2
PS-H2-20000 Hydrogen Module-3

Technical Specification Communication Protocol Module makes use of serial communication. Communication configuration parameters are:

 Open the catalog to page 3
PS-H2-20000 Hydrogen Module-4

Gas concentration = concentration (high byte)*256 + concentration (low byte)

 Open the catalog to page 4
PS-H2-20000 Hydrogen Module-5

/************************************************************************* *Function name:unsigned char FucCheckSum(uchar *i,ucharln) *Function description:checksum calibration[Take Not(Byte1+Byte2+…Byte7) +1] *Note:Take Not(Byte1+Byte2+…ByteX (X>2) *************************************************************************/ unsigned char FucCheckSum(unsigned char *i, unsigned char ln) { unsigned char j, tempq=0; i+=1; for(j=0; j<(ln-2); j++) { tempq+=*i; i++; } tempq=(~tempq)+1; return(tempq); } Avoid changing or moving sensor on the module. Avoid moving or changing electronic elements on PCB....

 Open the catalog to page 5
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.