The FC-VOC-100 VOC Sensor by ProSense is designed for high stability, good consistency, long service life, and strong anti-poisoning ability. It does not require baseline correction or periodical calibration.

Applications
This sensor is suitable for use in air cleaners, fresh air systems, air conditioners, indoor air quality monitoring, portable devices, and smart home applications.

Technical Specifications
  • Principle: Micro Fuel Cell
  • Range: 0-100ppm
  • Max Overload: 500ppm
  • Sensitivity: 50±20(nA/ppm)
  • Response Time (T90): <90 seconds
  • Baseline (20℃): ±3ppm
  • Repeatability: 2%
  • Linearity: Linear
  • Temperature Range: -20℃ to 60℃
  • Pressure: 1atm±10%
  • Humidity: 15%-90% (non-condensing)
  • Lifetime: 5 years in air
  • Warranty Period: 12 months
  • Weight: 3g

Functionality
The sensor operates on fuel cell technology, detecting VOCs through reactions at the working electrode, with current generated proportional to VOC concentration. It offers high stability, good consistency, and does not require zero compensation.

Dimensions
All dimensions are in mm with tolerances of ±0.15mm unless otherwise stated.

Precautions
  • Avoid exposure to organic solvents, corrosive gases, especially alkaline gases.
  • Do not store in dusty, dirty, or anaerobic environments.
  • Avoid permanent exposure to high concentrations of analytes.
  • Prevent excessive shock or vibration to avoid internal damage.
  • Disassembling the sensor voids the warranty.

Contact Information
ProSense Technologies Co., Ltd., Building 4, Lianjian S&T Park, Longhua District, Shenzhen, China. Tel: +86 755 3669 0079. Website: www.szprosense.com. Email: [email protected].
See more

Catalog excerpts

FC-VOC-100VOCSensor-1

The VOC sensor with the model of FC-VOC-lOO from ProSense works on the proven fuel cell technology and responds directly to the volume concentration of VOC. FC-VOC-lOO realizes the detection of VOC by the reaction occurred on the working electrode of the micro fuel cell, during which the current generated is proportional to the concentration of VOC. FC-VOC-lOO has the typical advantages of high stability, good consistency, anti-poisioning and no need for zero compensation. * High stability *Good consistency *Long service life *No need for baseline correctio *Strong anti-poisoning abili *No need for periodical calibration Indoor air quality monitoring Portable devices Smart home

 Open the catalog to page 1
FC-VOC-100VOCSensor-2

Notes:1 All dimensions in mm 2 All tolerances ±0.15mm unless otherwise stated Precautions 1 .The sensor should be prevented from organic solvents or corrosive gases,especially alkaline gases. 2 .The sensor should not be stored in dusty, dirty areas and anaerobic environment 3. The sensor must not be exposed to very high concentration of the analyte permanently 4 .Excessive shock or vibration should be prevented to avoid internal damage 4. Disassemble of the sensor will result in warranty free. ProSense Technologies Co., Ltd. Add: Building4, Lianjian S&T Park, LonghuaDistrict,Shenzhen,China; Tel:...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.