MemsFrontier CO2 Sensor Module

MemsFrontier CO2 Sensor Module

MemsFrontier CO2 Sensor Module

Product catalog summary
Introduction
This document provides technical specifications and application details for the NDIR CO2 Sensor Module, specifically models MTP40-D and MTP40-F, developed by Shenzhen MemsFrontier Electronics Co., Ltd. The sensor is designed for air quality monitoring in various environments such as smart agriculture and indoor ventilation systems.

Specifications
  • Measurement Range: 400ppm to 5000ppm CO2
  • Accuracy: ±(50ppm + 5% of reading)
  • Response Time: T90 time is 90 seconds
  • Operating Temperature: -20°C to 60°C
  • Operating Humidity: 0-90% RH non-condensed
  • Power Supply: 4.2V to 5.5V
  • Power Consumption: 300mA peak, 4mA normal, 13mA average
  • Dimensions: MTP40-D: 35.6x21.2x12.7mm, MTP40-F: 32.5x20x8.5mm

Operating Principle
The sensor operates using Non-Dispersive Infrared (NDIR) technology, which is known for its high sensitivity and automatic calibration algorithm.

Application Areas
The sensor is suitable for air detection in fresh air systems, smart farms, and car air purifiers.

Additional Features
  • Self Calibration Cycle: Initial time is 24 hours, subsequent cycles are 7 days
  • Alarm Output: Outputs 1 for >1000ppm, 0 for <800ppm
  • PWM Output: Period of 1004ms, Pulse of 2ms-1002ms for 0-5000ppm
See more

Catalog excerpts

MemsFrontier CO2 Sensor Module-1

NDIR CO 2 Sensor Module >>>>>>>>>>>> Automatic Calibration Algorithm High Sensitivity Email: [email protected] Shenzhen MemsFrontier Electronics Co., Ltd.

 Open the catalog to page 1
MemsFrontier CO2 Sensor Module-2

MTP40-D Target Gas Operating Principle Measurement Range Measurement Interval Accuracy Response Time Operating Temperature Operating Humidity Storage Temperature T90 time is 90s 0-50°C 0-90% RH non condensed -20°C---60°C 35.6X21.2X12.7mm(max dimensions) 32.5X20X8.5mm(max dimensions) Dimensions Power Supply 4.2V---5.5V 300mA peak, 4mA normal, 13mA average Power Consumption 10 years+ Life Expectancy Uart /IIC Serial Communication PWM Output Self Calibration Cycle Alarm Output Period: 1004ms, Pulse: 2ms-1002ms(0---5000ppm) Initial time is 24 hours, later is 7 days >1000ppm output to 1, <800ppm output...

 Open the catalog to page 2

All Shenzhen MemsFrontier Electronics Co., Ltd. catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.