• Applications I Radar,Motor Drives, Broadcast Transmitters. n X-Ray equipment , Lasers,Medical Defibrillators. IE Dynamic Braking, Soft-start/Current-limit equipment. IV Snubber Circuits, Dummy Loads, Energy Research field.. V RF Amplifiers,Semiconductor Process, Power Conditioning. • Introduction I HVA ’ s Resistor series are for high voltage,high energy and high current products. II HVA ’ s function is much better than carbon composition resistor, in some fileds, several carbon composition resistors can be replaced by only one ceramic resistor. H Operating ambient temperature:-55°C ~200°C. V Resistance value:3^~2M^. V Tolerance:K(± 10%),M(±20%) are recommended, F(±1 %),G(±2%)J(± 5%) are available. ^ For customerized products please contact with us. • Features I Special ceramic resistor , was made of Clay , Silicon dioxide and Porcelain cement ,After sintering under high temperature and high voltage , the resistor core was build ,then take the insulation coating. II Saver than the wire-wound resistor and film resistor , which will avoid the wire disconnecting and the film breaking up . E High peak power can be reached at 5KW-30KW in short time. V Good performance in bearing high voltage and high current. V Products meet the RoHS requirments. •Construction Series Name Power Resistance Forming Resistance Rating Tolerance (1)Type: HVA SERIES
Open the catalog to page 1*For resistors operated at an ambient temperature of 70°C or above,the power rating should be derated in accordance with the above derating curve. Remark: I Rating Ambient Temperature: + 70C h Operating temperature range :-40C + 200C IE Rated voltage= power rating*resistance value IV The maximum pulse voltage in the "resistance to pulse”examination condition of the performance column.
Open the catalog to page 2HVA Ceramic Resistors For Anti Pulse And Surge Resistance to Pulse 0.80% DC 20KV see circuit for test conditions DC 14 KV see circuit for test conditions Pulse Limiting Power(Po) One Pulse Pulse Time(s) Http://www.khxcom.com SHENZHEN KWX ELECTRONICS CO., LTD Http://www.kwxcom.com
Open the catalog to page 3Ambient temperature (°C)• Performance (Reference Standards: IEC60115-1 and JIS C5201-1 ) Test Items When testing the resistance value ,the ambient temperature should keep at 25C ± 2C and the moisture keep at 65%
Open the catalog to page 43 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
7 Pages
2 Pages
4 Pages
4 Pages
3 Pages
2 Pages
2 Pages
3 Pages
2 Pages
4 Pages
2 Pages
3 Pages
5 Pages
3 Pages
4 Pages
3 Pages
3 Pages
2 Pages
1 Page
2 Pages
3 Pages
2 Pages
2 Pages
3 Pages
2 Pages
2 Pages
3 Pages
3 Pages
2 Pages
3 Pages
2 Pages