Shenzhen Hongguang Display Co.,Ltd CUSTOMER : CUSTOMER MODULE : HL MODEL Preliminary Specification ■Final Specification Customer Confirmation column: Approved by : Please return one of the copies of the specification with your signature to us within two weeks after you receive this document.If it is not returned,we will assume that you agree to the entire contents of this specification document. Hongguang Display
Open the catalog to page 1Shenzhen Hongguang Display Co.,Ltd REVISION RECORD REV NO 1.0 Hongguang Display First Release
Open the catalog to page 2Shenzhen Hongguang Display Co.,Ltd TABLE OF CONTENT 1.0 GENERAL SPECIFICATIONS ELECTRICAL CHARACTERISTICS BACKLIGHT CHARACTERISTICS DIMENSIONAL DRAWING ELECTRO-OPTICAL CHARACTERISTICS INSPECTION CRITERIA PRECAUTIONS FOR USING LCD MODULE Hongguang Display
Open the catalog to page 3Shenzhen Hongguang Display Co.,Ltd 1.0 General Specifications HG101WS045-V0 is a color active matrix LCD module incorporatinga morphous silicon TFT (Thin Film Transistor). It is composed of a colorTFTLCD panel, driver IC, FPC and a back light unit. The module display areacontains 1024x 600pixels. This product accords with RoHS environmentalcriterion. Item Viewing direction Number of Dots Driver IC Backlight Type Interface Type Input voltage Hongguang Display
Open the catalog to page 4Shenzhen Hongguang Display Co.,Ltd 2.0 ELECTRICAL CHARACTERISTICS Item Power Voltage Input signal voltage Input logic high voltage Input logic low voltage DVDD AVDD Note1:If users use the product out off the environmemtal operation range(temperature and humidity),it will have visual quality concerns. Note2:Be sure to apply DVDD and VGL to the LCD first,and then apply VGH Note3:DVDD setting should match the signals output voltage(refer to Note4)of customer's system board. Note4:DCLK,HS,VS,RESET,U/D,L/R,DE,R0-R7.G0-G7,B0-B7,MODE,DITHB. Note5:Typical VCOM is only a reference value,it must be optimized...
Open the catalog to page 5Shenzhen Hongguang Display Co.,Ltd Current Consumption Item Symbol IGH IGL IVDD IAVDD BACKLIGHT CHARACTERISTICS Item Forward voltage Connection mode Hongguang Display
Open the catalog to page 6Shenzhen Hongguang Display Co.,Ltd 4.0 DIMENSIONAL DRAWING Hongguang Display
Open the catalog to page 7Shenzhen Hongguang Display Co.,Ltd 5.0 INTERFACE PIN CONNECTIONS Pin.No Power ground Common Voltage Digital Power DE/SYNC mode select. Normally pull high H: DE mode. L: HSD/VSD mode Data Enable signal. Vertical sync input. Negative polarity Horizontal sync input. Negative polarity Blue Data Green Data Colock signal Display on/off Left or Right Display Control Up / Down Display Control Analog Power Global reset pin. Active low to enter reset state. Suggest to connecting with an RC reset circuit for stability. Normally pull high. (R=10KΩ,C=1μF) Common Voltage Dithering setting DITH=”H” 6bit resolution(last...
Open the catalog to page 8Shenzhen Hongguang Display Co.,Ltd 5.1 Timing characteristics 5.1.1 AC Electrical Characteristics Item HS setup time HS hold time VS setup time VS hold time Data setup time Data hold time DE setup time DE hold time VDD Power On Slew rate RESET pulse width DCLK cycle time DCLK pulse duty Thst Thhd Tvst Tvhd Tdsu Tdhd Tesu Tehd TRST Tcoh Tcwh 5.1.2 Input Clock and Data Timing Diagram Hongguang Display
Open the catalog to page 9Shenzhen Hongguang Display Co.,Ltd 5.1.3 Timing DCLK Frequency Horizontal Display Area VS period time HS pulse width HS Blanking HS Front Porch Vertical Display Area VS period time VS pulse width VS Blanking VS Front Porch fclk thd fclk thpw thb thfp tvd tv tvpw tvb tvfp DCLK DCLK MHz DCLK DCLK DCLK TH TH TH TH TH 5.1.4 Data Input Format Hongguang Display
Open the catalog to page 10Shenzhen Hongguang Display Co.,Ltd 5.2 POWER ON/OFF SEQUENCE Hongguang Display
Open the catalog to page 11Shenzhen Hongguang Display Co.,Ltd 6. ELECTRO-OPTICAL CHARACTERISTICS Item Rise Time (Tr) (Tr+Td) Decay Time (Td) Response Time Decay Time (Td) ψ=0° Viewing Angle Range 6.1 Electro-Optical Characteristics Test Method Response Time Detector Photo-detector Light Source for Reflective Type Liquid Crystal Panel Light Source for Transmission Type Hongguang Disp
Open the catalog to page 12Shenzhen Hongguang Display Co.,Ltd 6.2 Definition of Operating Voltage, Vop Vop = (V10,ON +V90,OFF)/2 Brightness Curve for Selected Segment Driving Voltage Definition of Optical Response Time Non-selecte d Waveform Non-selected Waveform Selected Waveform Hongguang Display
Open the catalog to page 13Shenzhen Hongguang Display Co.,Ltd 6.4 Definition of Viewing Angle θ and 12 O’clock Direction 9 O’clock Direction 3 O’clock Direction φ=90° Viewing Direction 6 O’clock Direction 6.5 Definition of Contrast ratio, CR CR = Brightness of Non-selected Segment (B2) Brightness of Selected Segment (B1) Selected Segment Brightness Curve for 100% Non-selected Segment Contrast CR,max Hongguang Display Driving Voltage
Open the catalog to page 14Shenzhen Hongguang Display Co.,Ltd 7.INSPECTION CRITERIA 7.1 Inspection Conditions 7.11 Environmental conditions The environmental conditions for inspection shall be as follows Room temperature: 20±3°C Humidity: 65±20%RH 7.12 The external visual inspection With a single 20-watt fluorescent lamp as the light source, the inspection was in the distance of 30cm or more from the LCD to the inspector's eyes . Fluorescent lamp perpendicular to the display surface. Hongguang Display
Open the catalog to page 15Shenzhen Hongguang Display Co.,Ltd Inspection distance and angle Inspection should be performed within angleφ(φis usually 30°) from Z axis to each X and Y. Inspection distance in any direction within φmust be kept 30±5cm from the display surface. . 7.3 Classification of defects 7.3.1Major defect A major defect refers to a defect that may substantially degrade usability for product applications. 7.3.2 Minor defect A minor defect refers to a defect which is not considered to be able substantially degrade the product application or a defect that deviates from existing standards almost unrelated...
Open the catalog to page 16Shenzhen Hongguang Display Co.,Ltd 8.2 Tests NO. Test Item High Temperature Storage Test condition -30℃±2℃ 96H Restore 2H at 25℃ Power off High Temperature Operation 70℃±2℃ 96H Restore 2H at 25℃ Power on Low Temperature Operation -20℃±2℃ 96H Restore 2H at 25℃ Power on High Temperature & 60℃±2℃ 90%RH 96H Humidity Operation Power on Temperature Cycle --30℃←→25℃←→80℃ 30min 5min 30min after 10 cycle, Restore 2H at 25℃ Power off Vibration Test Shock Test Aftertesting,cosmeti c and electrical defects should not happen. 9 PRECAUTIONS FOR USING LCD MODULE 9.1 HANDING PRECAUTIONS (1) The display panel...
Open the catalog to page 1730 Pages
21 Pages
20 Pages
64 Pages
23 Pages
32 Pages
22 Pages
24 Pages
27 Pages
12 Pages
12 Pages
38 Pages
19 Pages
19 Pages
18 Pages
24 Pages
21 Pages
20 Pages
19 Pages
19 Pages
20 Pages
20 Pages
18 Pages
20 Pages
20 Pages
20 Pages
22 Pages
25 Pages
23 Pages
23 Pages
23 Pages
24 Pages
27 Pages
30 Pages
23 Pages
18 Pages
17 Pages
17 Pages
17 Pages
17 Pages
19 Pages
13 Pages
13 Pages
17 Pages
17 Pages
18 Pages
18 Pages
18 Pages
19 Pages
19 Pages
12 Pages
19 Pages
19 Pages
20 Pages
22 Pages
19 Pages
14 Pages
13 Pages
19 Pages
19 Pages
23 Pages
23 Pages
20 Pages
19 Pages
18 Pages
12 Pages
23 Pages
23 Pages
12 Pages
20 Pages
20 Pages
25 Pages
14 Pages
13 Pages
19 Pages
22 Pages
13 Pages
13 Pages
21 Pages
25 Pages
13 Pages
18 Pages
30 Pages
21 Pages
18 Pages
16 Pages
1 Page
16 Pages
20 Pages
16 Pages
20 Pages
39 Pages
50 Pages
50 Pages
49 Pages
7 Pages
20 Pages
30 Pages
17 Pages
21 Pages
30 Pages
30 Pages
17 Pages
19 Pages
15 Pages
17 Pages
19 Pages
14 Pages
22 Pages
19 Pages
16 Pages
16 Pages
18 Pages
10 Pages
17 Pages
19 Pages
20 Pages
17 Pages
17 Pages
21 Pages
21 Pages
19 Pages
14 Pages
16 Pages
20 Pages
18 Pages
19 Pages
19 Pages
19 Pages
18 Pages
18 Pages
29 Pages
18 Pages
12 Pages
21 Pages
18 Pages
18 Pages
20 Pages
19 Pages
10 Pages
10 Pages
10 Pages
20 Pages
19 Pages
19 Pages
20 Pages
20 Pages
20 Pages
13 Pages
13 Pages
26 Pages
13 Pages
22 Pages
24 Pages
19 Pages
13 Pages
13 Pages
13 Pages
13 Pages