Shenzhen Hongguang Display Co.,Ltd CUSTOMER : CUSTOMER MODULE : HL MODEL Preliminary Specification ■Final Specification Customer Confirmation column: Approved by : Please return one of the copies of the specification with your signature to us within two weeks after you receive this document.If it is not returned,we will assume that you agree to the entire contents of this specification document. Hongguang Display
Open the catalog to page 1Shenzhen Hongguang Display Co.,Ltd Revision History Version NO. Hongguang Display FIRST ISSUE
Open the catalog to page 2Shenzhen Hongguang Display Co.,Ltd CONTENTS GENERAL INFORMATION I/O CONNECTION & BLOCK DIAGRAM ELECTRICAL CHARACTERISTICS ELECTRO-OPTICAL CHARACTERISTICS RELIABILITY TEST CONDITIONS INSPECTION STANDARDS PACKAGE DRAWING Hongguang Display
Open the catalog to page 3Shenzhen Hongguang Display Co.,Ltd 1. GENERAL INFORMATION 1.1 1) Structure: TFT PANNEL+IC+FPC+BL+CTP 2) IPS Type LCD 800 dot-segment and 480 dot-common outputs 3) 252K Color can be selected by software 4) White LED back light 5) RGB-24 interface 6) Operation Temperature : -20~70℃ 7) Storage Temperature : -30~80℃ 8) CTP cover lens :Asahi 9) CTP structure :G+G 10) LED life time:-/ 1.2 General specification Item of Panel Size Display mode Normally Black Pixel arrangement Active Area Recommended Viewing Direction Hongguang Display
Open the catalog to page 4Shenzhen Hongguang Display Co.,Ltd 2.DIAGRAM FOR LCM Hongguang Display
Open the catalog to page 5Shenzhen Hongguang Display Co.,Ltd 3. I/O CONNECTION & BLOCK DIAGRAM 3.1 Power supply for LED+ Power Ground Power supply to the internal logic power regulator GREEN data BLUE data Power Ground Parallel RGB clock input Display control / standby mode selection Horizontal sync signal; negative polarity. Vertical sync signal; negative polarity. DATA INPUT Enable Power Ground Power Ground Hongguang Display
Open the catalog to page 6Shenzhen Hongguang Display Co.,Ltd 3.2 block diagram MCU and Display Module Interface Configuration MCU GND Power Block VCC LED_A LED_K Interface Block Hongguang Display Display Module R 0:7 G 0:7 B 0:7 DCLK DE DISP HSYNC VSYNC Interface Block
Open the catalog to page 7Shenzhen Hongguang Display Co.,Ltd 4. ELECTRICAL CHARACTERISTICS 4.1 Absolute Maximum Ratings Hongguang Display
Open the catalog to page 8Shenzhen Hongguang Display Co.,Ltd 4.2 Typical operation conditions 4.3 Backlight Driving Conditions Item Voltage for LED Backlight Current for LED Backlight LED life time Note 1: The “LED life time” is defined as the modulebrightness decrease to 50% original brightness that the ambient temperature is 25 ℃ and IL=40mA. TheLED lifetime could be decreased if operating IL is lager than 40 mA. Note 2: The LED Supply Voltage is defined by the number of LED at Ta=25 ℃ and IL=40mA. Hongguang Display
Open the catalog to page 9Shenzhen Hongguang Display Co.,Ltd 4.4 Power Sequence System power stability to GRB RESET signal GRB RESET= “High” to DISP=”High” Display Signal output to Backlight Power on Note : 1. When DISP pull “H” or “L”, IC will execute the internal power on or power off procedures .Please be careful about the timing of DISP and do not interrupt it during power on or power off procedure, otherwise unexpected errors will occur. 2. RGB interface Display signal: DCLK; VSYNC; HSYNC; DE; DR[7:0]; DG[7:0]; DB[7:0] 3: LVDS interface Display signal: DCLK P/N; RX[3:0] P/N Backlight Power off to DISP=”Low” DISP=”Low”...
Open the catalog to page 10Shenzhen Hongguang Display Co.,Ltd 4.5 Timing Characteristics 4.5.1 Timing Conditions Parallel 24-bit RGB Input Timing (PVDD=PVDD1=VDD=VDDI= 3.3V, AGND= 0V, TA=25C) Parallel 24-bit RGB Interface Timing Table Item DCLK Frequency Period Time Display Period Back Porch Front Porch Pulse Width Period Time Display Period Back Porch Front Porch Pulse Width Note: 1. The minimum blanking time depends on the GIP timing of the panel specification 2. To ensure the compatibility of different panels, it is recommended to use the typical setting. 3. It is necessary to keep Tvbp =12 and Thbp =43 in sync mode....
Open the catalog to page 11Shenzhen Hongguang Display Co.,Ltd 4.5.2 Timing Diagram Tclk DCLK (Negative Polarity) VSYNC (Negative Polarity) Tclk DCLK (Negative Polarity) HSYNC (Negative Polarity) DCLK (Negative Polarity) Tdehd Tdsu Tdhd Last data DCLK (Positive Polarity) VSYNC (Negative Polarity) Tcwh Tvhd DCLK (Positive Polarity) HSYNC (Negative Polarity) DCLK (Positive Polarity) Tdest DE (Positive Polarity) Hongguang Display Last data
Open the catalog to page 12Shenzhen Hongguang Display Co.,Ltd 5. ELECTRO-OPTICAL CHARACTERISTICS Parameter Horizontal Viewing Angle range Vertical Luminance Contrast ratio Color Gamut Reproduction of color Response Time Hongguang Display Note 2 % Note 5 @C Light
Open the catalog to page 13Shenzhen Hongguang Display Co.,Ltd Note : 1. Viewing angle is the angle at which the contrast ratio is greater than 10. The viewing are determined for the horizontal or 3, 9 o‟clock direction and the vertical or 6, 12 o‟clock direction with respect to the optical axis which is normal to the LCD surface. Contrast measurements shall be made at viewing angle of = 0 and at the center of the LCD surface. Luminance shall be measured with all pixels in the view field set first to white, then to the dark (black) state. (See FIGURE 1 shown in Appendix) Luminance Contrast Ratio (CR) is defined mathematically....
Open the catalog to page 14Shenzhen Hongguang Display Co.,Ltd Note4.Definition of Viewing Angle: The viewing angle range that the CR≥10 Note 5: Definition of Color Chromaticity (CIE 1931) Color coordinate of white & red, green, blue at center point. Hongguang Display
Open the catalog to page 15Shenzhen Hongguang Display Co.,Ltd 6. RELIABILITY TEST CONDITIONS No Test Item Test Condition STANDARD 1. Functional test is OK. Missing Segment, short, unclear segment, on-display, display abnormally and liquid crystal leak are un-allowed. 2. No low temperature bubbles, end seal loose and fall, frame rainbow. 1. Function test is OK. 2. No glass crack, chipped glass, end seal loose and fall, epoxy frame crack and so on. 3. No structure loose and fall. High Temperature Storage High Temperature Operating Thermal and cold shock Operate at High Temperature and Humidity Vibration Test Dropping test...
Open the catalog to page 1630 Pages
21 Pages
20 Pages
64 Pages
23 Pages
32 Pages
22 Pages
24 Pages
27 Pages
12 Pages
12 Pages
38 Pages
19 Pages
19 Pages
18 Pages
24 Pages
21 Pages
20 Pages
19 Pages
19 Pages
20 Pages
20 Pages
18 Pages
20 Pages
20 Pages
20 Pages
22 Pages
25 Pages
23 Pages
23 Pages
23 Pages
24 Pages
27 Pages
30 Pages
23 Pages
18 Pages
17 Pages
17 Pages
17 Pages
22 Pages
17 Pages
19 Pages
13 Pages
13 Pages
17 Pages
17 Pages
18 Pages
18 Pages
18 Pages
19 Pages
19 Pages
12 Pages
19 Pages
19 Pages
20 Pages
22 Pages
19 Pages
14 Pages
13 Pages
19 Pages
19 Pages
23 Pages
23 Pages
20 Pages
19 Pages
18 Pages
12 Pages
23 Pages
23 Pages
12 Pages
20 Pages
20 Pages
25 Pages
14 Pages
13 Pages
19 Pages
22 Pages
13 Pages
13 Pages
21 Pages
25 Pages
13 Pages
18 Pages
30 Pages
21 Pages
18 Pages
16 Pages
1 Page
16 Pages
20 Pages
16 Pages
20 Pages
39 Pages
50 Pages
50 Pages
49 Pages
7 Pages
20 Pages
30 Pages
17 Pages
21 Pages
30 Pages
30 Pages
17 Pages
19 Pages
15 Pages
17 Pages
19 Pages
14 Pages
22 Pages
19 Pages
16 Pages
16 Pages
18 Pages
10 Pages
17 Pages
20 Pages
17 Pages
17 Pages
21 Pages
21 Pages
19 Pages
14 Pages
16 Pages
20 Pages
18 Pages
19 Pages
19 Pages
19 Pages
18 Pages
18 Pages
29 Pages
18 Pages
12 Pages
21 Pages
18 Pages
18 Pages
20 Pages
19 Pages
10 Pages
10 Pages
10 Pages
20 Pages
19 Pages
19 Pages
20 Pages
20 Pages
20 Pages
13 Pages
13 Pages
26 Pages
13 Pages
22 Pages
24 Pages
19 Pages
13 Pages
13 Pages
13 Pages
13 Pages