Catalog excerpts
Website: www.garleuv.com Email: sales@garleuv.com GL2000 SERIES UV lED DATA SHEET Maximum channels Output voltage range (V) Note: One master unit can operate together with up to 3 slave units to achieve maximum 12KW. Slave unit can't operate independently. 2. Basic Specification Rated voltage and frequency Voltage Allowable Variation Range Standard configuration: 4 digital inputs DI1/DI2/DI3/DI4 Standard configuration: 2 channels of 0~10V voltage input or 0~20mA current input optional (AI1/AI2) output voltage Digital output DO Standard configuration: 2-way NTC temperature input, NTC temperature resistance and coefficient can be set 48V/62V/90V/120V/140V/180V optional Standard configuration:
Open the catalog to page 1Website: www.garleuv.com Analog output AO relay contact output Email: sales@garleuv.com 2 channels 0.0~10.0V voltage output signal AO1/AO2 2 sets of AC 250V/2A normally open, normally closed contacts Protection/Alarm function Input phase loss, output over voltage, output over current, machine overheating, module temperature detection, output disconnection, etc. Ambient temperature and humidity -10ºC to +45ºC (no freezing), below 90% (no frosting) Protection class cooling method Slav e Mounting hole (mm) 4. UV power supply control loop wiring diagram Wall mounted Carton/ Poly wooden case...
Open the catalog to page 2Website: www.garleuv.com Email: sales@garleuv.com UV LED module RS-485 communication, support Modbus protocol Port for external keyboard and touch screen Analog output Analog output Analog input Analog input Multi-function open collector output Connect to external NTC thermistor "Main circuit terminals, " Fault contact output Fault contact output "Control circuit terminals。 GL2000 series installation space requirements are various as following: Air out Power level
Open the catalog to page 3The heat dissipation of power supply is bottom-up. Usually they are mounted side-by-side if several power supplies working together. Email: sales@garleuv.com If two rows installation are unavoidable, a guide plate should be installed between them as below. Because the hot air from bottom row will be taken in to the upper EPS and lead to high temperature and malfunction.
Open the catalog to page 4Website: www.garleuv.com Email: sales@garleuv.com 6. Operation panel (optional) 安 装 板 开plate opening size:127*67mm mm Mounting 孔 尺 寸 : External LCD keyboard Shuttle keyboard Dimension
Open the catalog to page 5