G5800

G5800

G5800

Product catalog summary
1. Specifications
The G5800B series includes various models with lamp power ranging from 3KW to 45KW. Input voltage options are 220V and 380V, with corresponding input currents and output voltage ranges. The maximum output current and recommended lamp voltage vary by model, with higher power models supporting higher voltages and currents.

2. Basic Specification
Input voltage is nominally 380V for the 4T series and 220V for the 2S/2T series, with a voltage range of -10% to +15%. The output voltage ranges from 450V to 3500V for the 4T series and 200V to 240V for the 2S series. The control method is power vector control, with a power setting resolution of 0.1KW. RS485 communication is available for device control and status monitoring.

3. Dimensions
Dimensions vary by power level, with specific mounting hole sizes and installation methods. Models above 22KW are packed in poly wooden cases for protection.

4. Installation Requirements
Installation space requirements depend on power level, with specific clearances needed for heat dissipation. Multiple units should be installed side by side horizontally, with a metal plate required for vertical installations.

5. Operation Panel
An optional operation panel includes an external LCD keyboard and shuttle keyboard, with specific mounting plate opening dimensions.
See more

Catalog excerpts

G5800-1

Website: www.garleuv.com Email: [email protected] G5800B SERIES DATA SHEET 1. G5800B Specifications Max output current (A) Lamp voltage recommended (V) Input Current Output voltage (A

 Open the catalog to page 1
G5800-2

Website: www.garleuv.com Email: [email protected] Note: If input voltage is 480V, output voltage will be increased 20%. Nominal voltage, frequency Voltage range

 Open the catalog to page 2
G5800-3

Website: www.garleuv.com Email: [email protected] Standard configuration 3 digital input DI1/DI2/DI3 Standard:0~10V voltage input(AI) or 0~20mA current input(AI) Output voltage Output frequency Digital output DO Standard configuration 3 channel digital output DO1/DO2/DO3 2 channel 0~10V voltage output signal Relay contact output Power vector control Control method Power setting resolution Control characteristics 110% of the rated current of the lamp Voltage limit 110% of the rated voltage of the lamp Standby function Lamp timer function Running function RS485 communication interface, which can...

 Open the catalog to page 3
G5800-4

Website: www.garleuv.com Protection class Cooling method Email: [email protected] Applicable to 22KW and below model Applicable to 25KW and above models Carton/ Poly wooden case size(mm) Install method Wall mounted Note: all models > 22KW will be packed with poly wooden case to provide appropriate pr

 Open the catalog to page 4
G5800-5

Website: www.garleuv.com 4. UV power supply control loop wiring diagram Email: [email protected] The installation space of UV electronic power supply requires as below: Air out Power level

 Open the catalog to page 5
G5800-6

Website: www.garleuv.com Email: [email protected] The heat of EPS dissipates from the bottom part to the top. For more than 1 pcs EPS installation, Please have them installed side by side horizontally. Considering the heat dissipation performance, a mental plate is required to be installed as below If vertically installation is unavoidable:

 Open the catalog to page 6
G5800-7

6. Operation panel (optional) Website: www.garleuv.com Email: [email protected] Mounting 开 孔 尺 寸 : size:127*67mm plate opening 安装板 mm External LCD keyboard Shuttle keyboard Dimension

 Open the catalog to page 7

All Shenzhen GARLE eletric technologies Co., LTD catalogs and technical brochures

  1. GL2000

    5  Pages

  2. G6000

    7  Pages

  3. G3600

    5  Pages

  4. G3000

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.