Preface To help you better use the product and protect you and the product safety, please carefully read and understand the relevant security information and about the equipment and user manual information before operating this product. disclaimer Following the contents of the user manual is a prerequisite for safe operation, and also a prerequisite for achieving the described performance features and product functions; Our company shall not bear the responsibility for the material loss, economic loss or personal injury caused by the neglect of the product information; Copyright Statement...
Open the catalog to page 4Safe This instruction is very important for the installation and use of a static reactive power generator (SVG). Ignoring these instructions may cause you physical injury and even death. The following safety information summarizes the safety measures required for the operation of the equipment and its components. Follow the safety tips and safety information to ensure your personal safety and avoid material and economic losses. 1. The symbol used Safety information is marked with a symbol, according to the danger level, the danger level is shown as follows: take care Please always pay...
Open the catalog to page 5SVG user's manual ◆ It is strictly prohibited to place combustible materials near the SVG equipment or install them in the ◆ Ensure that the input power is completely disconnected before installation and wiring, otherwise there is environment containing explosive gas, otherwise there is a risk of fire or even explosion; ◆ Bare cables, power terminal joints, and ungrounded live equipment may cause electric shock. Please ask the risk of electric shock; after power on, never touch the SVG and other parts of the equipment; the electrical engineer or professional technician to confirm that the...
Open the catalog to page 6Chapter I: Delivery, Inspection and Storage
Open the catalog to page 7Chapter Ⅰ. Arrival Inspection and Storage 1.1 Transportation Each set of stationary reactive power generator (SVG) is generally transported through carton packaging (default carton, optional wooden box). buffer foam cotton and other protective items are placed in the carton, but they can not be inverted or tilted in the process of transportation and handling, so as to ensure that the filter can not be damaged in the process of movement. 1.2 Receiving and checking the equipment SVG equipment has been professionally tested and inspected before leaving the factory, and is prepared according to...
Open the catalog to page 8Foam cotton cushioning Test reports. Certificates of conformity. Manuals Figure 1-1 Appearance diagram of the rack type 1.4 Storage ♦ Packaging of SVG equipment avoids long-term outdoor storage, can be stored indoors for 6 months (from the date of delivery), if you need to store for a longer time, order can propose to the company to make a longer storage time packaging; ♦ If the SVG equipment is not installed immediately, the SVG equipment should be placed in the warehouse of dry, ventilated, no dust and corrosive substances, and no strong mechanical vibration and magnetic field in the...
Open the catalog to page 9SVG user's manual Chapter II. Product Overview 2.1 Appearance and composition of the products SVG series products can be divided into rack, wall mounted and vertical according to the installation mode. Each installation mode module has 200V / 400V / 480V and 690V voltage grade products, and the product capacity covers 50 kVar ~ 200 kVar. The 4.3-inch LCD display is an optional module, and you can choose whether to have a screen according to the requirements. 2.1.1 Appearance Take the rack-type 75 kVar, with the screen module as an example.
Open the catalog to page 11Under the same specification, the screen-free module and the screen module are the same as the overall size. Below, the screen module is taken as an example.
Open the catalog to page 12Figure 2-3 rack type dimensions
Open the catalog to page 13The SVG module adopts intelligent air cooling. During the design of the complete system, the heat dissipation design shall meet the following requirements: For example, the complete cabinet of SVG-400kVar should be designed to 4 times of the SVG-100kVar module (required air volume, minimum air inlet area, minimum opening size of front and rear door panels). 2.5 Implementation standards Specification and standards mainly implemented by the equipment (but not limited to this) GB / T 12325-2008, Power Quality, Power Supply Voltage Deviation; GB12326-2008, Power Quality, Voltage fluctuation and...
Open the catalog to page 16SVG user's manual GB50171-1992 Code for Construction and Acceptance of Engineering Plate, Cabinet and Secondary Circuit Line of Electrical Equipme
Open the catalog to page 17SVG user's manual ♦ Use a suitable line disconnecting switch / circuit breaker / fuse; ♦ Even after disconnection from the power supply / grid, dangerous voltage may still exist in the equipment or components (capacitor); ♦ Do not operate the equipment when the current transformer circuit is open; ♦ Do not make the SVG equipment run at full load for a long time, and do not set the parameters beyond the limit value that the equipment can bear; ♦ Note the warning and safety identification of all documents related to the equipment; ♦ Please pay attention to all warnings and safety signs in the...
Open the catalog to page 20◆SVG equipment must be installed in the electrical control room, the room must maintain a good ◆Air inlet and air outlet must have professional rain, dustproof, sand prevention treatment, necessary fire ventilation environment; ◆If there are serious dust and fly ash problems on the installation site, it is recommended to specially and rodent prevention treatment; protect SVG equipment to avoid the reduction of equipment efficiency, service life, failure and damage. ◆ The installation surface must be smooth and dry, and the ground is strictly prohibited from standing ◆ Make sure that the...
Open the catalog to page 22Figure 3-1 Frack front panel Take the 300kVar reactive power compensation cabinet (composed of 475kVar modules) as an example: Recommended size W * L * H (mm) 800*800*2200 Reactive compensation cabinet
Open the catalog to page 23*Back fastener *Clearance between guide rail and module: 2mm
Open the catalog to page 24All Shenzhen Consnant Technology Co. catalogs and technical brochures
-
Outdoor product collection
1 Pages
-
Hybrid Telecom system
1 Pages
-
Industrial Online UPS
2 Pages
-
High Frequency Online UPS
2 Pages
-
Solar Power System
1 Pages
-
APF&SVG
1 Pages
-
Industrial Online UPS CE
1 Pages
-
Product certification
2 Pages
-
Inverter certification
1 Pages
-
Inverter certification
1 Pages
-
SVG -LVD test report
61 Pages
-
SVG-EMC test report
33 Pages
-
APF-LVD test report
39 Pages
-
APF- EMC test report
33 Pages
-
SVG CE certificate
1 Pages
-
APF CE certificate
1 Pages
-
ISO System Certificate
6 Pages
-
ODU Telecom Cabinet
12 Pages
-
Industrial Online UPS
1 Pages
-
Home ESS
1 Pages
-
APF/SVG
1 Pages
-
Product Collection
1 Pages
-
Energy storage batteries
1 Pages
-
Lead-acid Battery Series
12 Pages
-
Industrial Outdoor UPS(1)
3 Pages
-
Rack Mount Online UPS 1-3KVA
5 Pages
-
Home ESS SmartCute series
4 Pages
-
APF(SVG)
10 Pages
-
Consant user manual
34 Pages
-
Hybrid Solar Inverter
1 Pages
-
Outdoor UPS
1 Pages
-
ESS
1 Pages
-
Moduar UPS
1 Pages
-
ODU system specification
11 Pages
-
lithium portable power supply
22 Pages
-
Modular online UPS 600KW
41 Pages
-
Micro Modular Data Center
16 Pages
-
Power Module 50KW
14 Pages
-
CE certificate
1 Pages
-
outdoor ups CNW110
2 Pages
-
electricity online ups
2 Pages