Test Report Overview
This document is a CE-EMC test report for Shenzhen Consnant Technology Co., Ltd.'s Lithium battery module, model 48100. Testing was conducted by Shenzhen HUAK Testing Technology Co., Ltd. from August 22 to August 29, 2023, confirming compliance with the 2014/30/EU requirements.
Standards and Compliance
The product was tested against standards including EN 55032:2015 + A1:2020 + A11:2020 and EN 55035:2017 + A11:2020, with results indicating compliance.
Test Summary
Tests were categorized into EMC Emission and EMC Immunity tests, including:
  • Conducted Emission (AC and Telecommunication ports) - Class B
  • Radiated Emission - Class B (Passed)
  • Harmonic Current Emission - Class A
  • Voltage Fluctuations & Flicker
  • Electrostatic Discharge (ESD) - Performance Criteria B (Passed)
  • RF Electromagnetic Field - Performance Criteria A (Passed)
Test Facility and Equipment
Tests were conducted at Shenzhen HUAK Testing Technology Co., Ltd., accredited by A2LA, FCC, and CNAS. Instruments used include LISN, EMI Test Receiver, and various antennas and amplifiers, calibrated until February 16, 2024.
General Information
The EUT is a Lithium battery module with a power rating of DC51.2V. Test modes included discharging and charging.
Measurement Uncertainty
The report provides measurement uncertainty for conducted and radiated tests, ensuring a 95% confidence level.
Test Results Overview
The report covers radiated emission measurements, harmonics current, voltage fluctuation and flickers, and EMC immunity tests, conducted under specific environmental conditions with a DC supply of 51.2V.
Radiated Emission Measurement
  • Limits: Defined for frequencies below and above 1000MHz, with specific dBuV/m values for Class A and Class B at different distances.
  • Procedure: Measurements were taken at a 10m distance for frequencies up to 1GHz, and at suitable distances for frequencies above 1GHz. The EUT was placed on a rotating table to identify the highest radiation position.
  • Results: Tests were conducted in both horizontal and vertical polarizations, with the worst-case results reported.
Harmonics Current
  • Limits and Procedure: The EUT was classified according to EN 61000-3-2 standards, and tests were conducted to measure harmonic currents under normal operating conditions.
  • Results: Not applicable as the EUT was tested by DC power supply.
Voltage Fluctuation and Flickers
  • Limits and Procedure: Tests were performed according to IEC standards, using a flicker-meter for direct measurement.
  • Results: Not applicable as the EUT was tested by DC power supply.
EMC Immunity Test
  • Standards and Criteria: Tests were conducted according to IEC/EN standards, covering ESD, RS, EFT/Burst, surges, injected current, power frequency magnetic field, and voltage interruptions/dips.
  • Performance Criteria: Defined as Criterion A, B, and C, specifying the expected performance and recovery of the equipment post-testing.
  • ESD Testing: Conducted with air and contact discharges at specified kV levels, with results indicating compliance with Criterion B.
1. Overview
This document details electromagnetic compatibility tests on a lithium battery module, Model 48100, based on IEC/EN standards.
2. RS Testing
Specification: Based on IEC/EN 61000-4-3, with a frequency range of 80 MHz to 5000 MHz and a field strength of 3 V/m. The modulation used is a 1kHz sine wave with 80% AM modulation.
Procedure: The EUT was placed in a fully-anechoic chamber, with tests conducted at a 3-meter distance from the antenna. The frequency range was swept incrementally with a step size of 1% of the fundamental frequency.
Results: The EUT passed the test with no operational changes during testing (Criteria A).
3. EFT/Burst Testing
Specification: Conducted according to IEC/EN 61000-4-4 with test voltages of 1 kV for power lines and 0.5 kV for signal/control lines.
Procedure: The EUT was placed on a table above a metal ground plane, with discharges applied in both positive and negative polarities.
Results: Not applicable as the EUT was tested by DC power supply.
4. Surge Testing
Specification: Based on IEC/EN 61000-4-5, with test voltages of 0.5 kV, 1 kV, and 2 kV applied to power lines.
Procedure: Surges were applied via capacitive coupling networks, with decoupling networks used to prevent adverse effects on other equipment.
Results: Not applicable as the EUT was tested by DC power supply.
5. Injection Current Testing
Specification: Conducted according to IEC/EN 61000-4-6, with a frequency range of 0.15-80 MHz and field strengths varying from 3 V r.m.s to 1 V r.m.s.
Procedure: The frequency range was swept with 80% amplitude modulation, and the dwell time was sufficient for EUT response.
Results: Not applicable as the EUT was tested by DC power supply.
6. Power Frequency Magnetic Field Testing
Specification: Based on IEC/EN 61000-4-8, with a field strength of 1 A/m at 50Hz.
Procedure: The EUT was exposed to a magnetic field using an induction coil, with tests conducted in different orientations.
Results: Not applicable as the EUT does not contain intrinsically susceptible equipment.
7. Voltage Interruption/Dips Testing
Specification: Conducted according to IEC/EN 61000-4-11, with performance criteria B and C for voltage dips and interruptions.
Procedure: The EUT was subjected to sequences of voltage dips and interruptions, with abrupt changes occurring at zero crossings of the voltage waveform.
Results: Not applicable as the EUT was tested by DC power supply.
8. Conclusion
The report concludes with photographs of the EUT and notes that several tests were not applicable due to the EUT being powered by a DC supply.
See more

Catalog excerpts

Home energy storage CE-EMC-Test report-1

HUAK TESTING CE-EMCTEST REPORT Prepared for : Shenzhen Consnant Technology Co., Ltd. Building B6, Junfeng Industrial Park, Yonghe Road, Fuhai Sub-District, Bao'an District, Shenzhen City, 518103 P.R.China Product: Lithium battery module Trade Mark: Model Name: Date of Test: Date of Report: Report Number: Prepared By : Shenzhen HUAK Testing Technology Co., Ltd. 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China TEL: +86-755-2302 9901 FAX: +86-755-2302 9901 E-mail: [email protected] http://www.cer-mark.com The results shown in this test report refer only to the sample(s) tested unless otherwise stated and the sample(s) are retained for 30 days only. The document is issued by HUAK, this document cannont be reproduced except in full with our prior written permission. The more details and the authenticity of the report will be confirmed at http://www.cer-mark.com. TEL :+86-755 2302 9901 FAX : +86-755 2302 9901 E-mail: [email protected] Add: 1-2F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

 Open the catalog to page 1
Home energy storage CE-EMC-Test report-2

TEST REPORT VERIFICATION Applicant Address Manufacturer Address EUT Description (A) Model No. (B) Series Model (C) Power Supply Shenzhen Consnant Technology Co., Ltd. Building B6, Junfeng Industrial Park, Yonghe Road, Fuhai Sub-District, Bao'an District, Shenzhen City, 518103 P.R.China Shenzhen Consnant Technology Co., Ltd. Building B6, Junfeng Industrial Park, Yonghe Road, Fuhai Sub-District, Bao'an District, Shenzhen City, 518103 P.R.China Lithium battery module 48100 N/A DC51.2V This device described above has been tested by HUAK, and the test results show that the equipment under test (EUT)...

 Open the catalog to page 2
Home energy storage CE-EMC-Test report-3

Table of Contents Page 1 . TEST SUMMARY 6 2.2 DESCRIPTION OF TEST MODES 9 2.3 DESCRIPTION OF TEST SETUP 10 2.4 DESCRIPTION TEST PERIPHERAL AND EUT PERIPHERAL 11 2.5 MEASUREMENT INSTRUMENTS LIST 12 3.1 CONDUCTED EMISSION MEASUREMENT 3.1.1 POWER LINE CONDUCTED EMISSION 3.1.2 TEST PROCEDURE 3.1.3 TEST SETUP 3.1.4 EUT OPERATING CONDITIONS 3.1.5 TEST RESULTS 3.2 RADIATED EMISSION MEASUREMENT 3.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT 3.2.2 LIMITS OF RADIATED EMISSION MEASUREMENT 3.2.3 TEST PROCEDURE 3.2.4 TEST SETUP 3.2.5 EUT OPERATING CONDITIONS 3.2.6 TEST RESULTS 3.2.7 TEST RESULTS(1000~6000MHz)...

 Open the catalog to page 3
Home energy storage CE-EMC-Test report-4

Table of Contents Page 4.2 GENERAL PERFORMANCE CRITERIA 29 4.3 GENERAL PERFORMANCE CRITERIA TEST SETUP 29 4.7 SURGE TESTING 4.7.1 TEST SPECIFICATION 4.7.2 TEST PROCEDURE $4.7.3 TEST SETUP 4.7.4 TEST RESULTS 4.8 INJECTION CURRENT TESTING 4.8.1 TEST SPECIFICATION 4.8.2 TEST PROCEDURE 4.8.3 TEST SETUP 4.8.4 TEST RESULTS 4.9 POWER FREQUENCY MAGNETIC FIELD TESTING 45 4.10 VOLTAGE INTERRUPTION/DIPS TESTING 48 5 . EUT TEST PHOTO 50 ATTACHMENT PHOTOGRAPHS OF EUT 51 The results shown in this test report refer only to the sample(s) tested unless otherwise stated and the sample(s) are retained for 30 days...

 Open the catalog to page 4
Home energy storage CE-EMC-Test report-5

** Modified History ** Revision The results shown in this test report refer only to the sample(s) tested unless otherwise stated and the sample(s) are retained for 30 days only. The document is issued by HUAK, this document cannont be reproduced except in full with our prior written permission. The more details and the authenticity of the report will be confirmed at http://www.cer-mark.com. TEL :+86-755 2302 9901 FAX : +86-755 2302 9901 E-mail: [email protected] Add: 1-2F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,...

 Open the catalog to page 5
Home energy storage CE-EMC-Test report-6

1. TEST SUMMARY Test procedures according to the technical standards: (1)” N/A” denotes test is not applicable in this Test Report (2) Voltage dip: 100% reduction - Performance Criteria B Voltage dip: 30% reduction - Performance Criteria C Voltage Interruption: 100% Interruption - Performance Criteria C (3) For client’s request and manual description, the test will not be executed. The results shown in this test report refer only to the sample(s) tested unless otherwise stated and the sample(s) are retained for 30 days only. The document is issued by HUAK, this document cannont be reproduced...

 Open the catalog to page 6
Home energy storage CE-EMC-Test report-7

1.1 TEST FACILITY Shenzhen HUAK Testing Technology Co., Ltd. Address: 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Testing Laboratory Authorization : A2LA Accreditation Code is 4781.01. FCC Designation Number is CN1229. Canada IC CAB identifier is CN0045. CNAS Registration Number is L9589. 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U , where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2 , providing a level of confidence of approximately...

 Open the catalog to page 7
Home energy storage CE-EMC-Test report-8

2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF EUT Equipment Model Name Series Model Model Difference Lithium battery module 48100 N/A N/A The EUT is a Lithium battery module. Product Description Operating frequency: Based on the application, features, or specification exhibited in User's Manual, the EUT is considered as an ITE/Computing Device. More details of EUT technical specification, please refer to the User's Manual. Power Source Power Rating The results shown in this test report refer only to the sample(s) tested unless otherwise stated and the sample(s) are retained for 30 days only....

 Open the catalog to page 8
Home energy storage CE-EMC-Test report-9

2.2 DESCRIPTION OF TEST MODES To investigate the maximum EMI emission characteristics generates from EUT, the test system was pre-scanning tested base on the consideration of following EUT operation mode or test configuration mode which possible have effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively. The results shown in this test report refer only to the sample(s) tested unless otherwise stated and the sample(s) are retained for 30 days only. The document is issued by HUAK, this document cannont be reproduced...

 Open the catalog to page 9

All Shenzhen Consnant Technology Co., Ltd. catalogs and technical brochures

  1. APF&SVG

    1  Page

  2. Home ESS

    1  Page

  3. APF/SVG

    1  Page

  4. APF(SVG)

    10  Pages

  5. Outdoor UPS

    1  Page

  6. ESS

    1  Page

  7. Moduar UPS

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.