1. Catalogs
  2. Shaw Moisture Meters
  3. SDT-Ex Dewpoint Transmitter Specification Sheet

SDT-Ex Dewpoint Transmitter Specification Sheet
1 /3Pages

SDT-Ex Dewpoint Transmitter Specification Sheet

SDT-Ex Dewpoint Transmitter Specification Sheet
1 /3Pages

Catalog excerpts

SDT-Ex Dewpoint Transmitter Specification Sheet-1

SDT-Ex Intrinsically Safe Dewpoint Transmitter Shaw Moisture Meters SDT-Ex is a compact, 3 wire, 4-20 mA dewpoint transmitter designed to meet the stringent demands of industrial applications. The SDT-Ex is certified intrinsically safe to ATEX: Ex II 1 GD Ex ia IIC T4 Ga (-20 °C ≤ Ta ≤ +60 °C) IECEx: Ex ia IIIC T200135 °C Da (-20 °C ≤ Ta ≤ +60 °C) for use in hazardous areas using a signal isolator. Incorporating advanced electronics, this dew point transmitter derives its power from a 7 - 28 V DC non-isolated power source and is configured to output a linear, isolated, 4 - 20 mA signal for distances up to 1,000 meters (3,280 ft). Utilising the Ultra High Capacitance Shaw Moisture Sensor, various dewpoint ranges are available covering an overall range from -100 °C to +20 °C dewpoint. The 4 - 20 mA output is configurable in °C dewpoint, °F dewpoint, ppm(V), ppb(v), g/m³ and lb/MMSCF. The unit is fully self-contained within a robust housing, providing weatherproof protection to IP66/NEMA 4X. The SDT-Ex dewpoint transmitter is supplied ready to use, with a Certificate of Calibration traceable to National & International Humidity Standards at NPL, instruction manual and two metres (6.56 feet) of cable. 0598 3 wire, 24 V, 4 - 20 mA dewpoint transmitter Weatherproof rating IP66 – NEMA 4X Intrinsically safe to ATEX and IECEx standards Open/short circuit detection Linear 4 - 20 mA output signal Self-contained, robust and reliable Supplied with Certificate of Calibration traceable to National & International Humidity Standards at NPL ATEX II 1 GD Ex ia IIC T4 Ga (-20 °C ≤ Ta ≤ +60 °C) IECEx Ex ia IIIC T200135 °C Da (-20 °C ≤ Ta ≤ +60 °C) Overall range -100 °C to +20 °C dewpoint Output configurable in °C , °F dewpoint, ppm(V), ppb(v), g/m

 Open the catalog to page 1
SDT-Ex Dewpoint Transmitter Specification Sheet-2

Specifications DEWPOINT SENSOR Electromagnetic Compatibility (EMC) Immunity: complies with EN 61000-6-1:2001 Emissions: complies with EN 61000-6-3:2000 Warm Up Time: 10 seconds Isolation Sensing element connected to the 4 - 20 mA loop but isolated from transmitter body Output Signal: 4 - 20 mA Linear Sensing Element Shaw Ultra High Capacitance Aluminium Oxide Sensor Ranges Dewpoint = 0.1 °C/0.2 °F resolution ZD: -100 °C to +20 °C (-148 °F to +68 °F) dewpoint HD: -65 °C to +20 °C (-85 °F to +68 °F) dewpoint P (Purple):-100 to 0 °C (-148 to +32 °F) dewpoint, 0 - 6,000 ppm(V) S (Silver):-100 to...

 Open the catalog to page 2
SDT-Ex Dewpoint Transmitter Specification Sheet-3

Ordering Information Related Products To order a SDT-Ex Dewpoint Transmitter SU4 Sample Conditioning Unit SDT-Ex - (Range) R - Choose required range: The SU4 sample conditioning unit reduces the pressure from the dryer to give a pressure and flow suitable for trace moisture measurement. Combining pressure reduction control, a sensor holder and a flow meter for up to 10 litres per minute, (1 -2 litre is usual for continuous use), mounted on a stove enamelled back plate. P (Purple) S (Silver) G (Grey) R (Red) B (Blue) -100 to 0 °C (-148 to +32 °F) dewpoint -100 to -20 °C (-148 to -4 °F) dewpoint...

 Open the catalog to page 3

All Shaw Moisture Meters catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.