Product catalog summary
Description: The ZCTR04 is a display device designed for the ZCT100-485 series 1-axis tilt sensor. It displays the current output angle and allows users to set an alarm angle. If the angle exceeds the set alarm angle, the device triggers an alarm with lighting and activates an internal relay to control an external circuit.
Technical Data:
  • Operating Voltage Range: 9-36 V DC
  • Quiescent Current: <80 mA
  • Display Resolution: 0.1 Degree
  • Baud Rate: 9600 bps
  • Relay Voltage of Trigger: Max 125V AC, Max 60V DC
  • Relay Load Ability: 1A 30VDC, 0.3A 60VDC, 0.5A 125VAC
  • Operating Temperature: -20 to +60 ℃
  • Outline Size: 72x72x120 mm (W*L*H)
Connector Definition: The device has 12 pins for various connections including power, ground, and communication with the ZCT100-485 series tilt sensor. Specific pins are designated for power input, ground, and relay triggers.
Relay Instructions: The internal relay activates when the angle exceeds the alarm threshold, closing the circuit and triggering an external alarm. Users must adhere to maximum voltage and current specifications.
Button Operation: The device features a MODE button for switching between major and secondary states, and a SETTING button for configuring parameters. There are four major states and three secondary states, each serving different functions such as zero clearing and alarm angle setting.
Operating Instructions: The device operates in various states:
  • State 0: Default angle display
  • State 1: Zero clearing
  • State 2 & 3: Display and set alarm angle
  • State 4: Set relative zero
  • State 5 & 6: Set alarm angle with different increments
Structure Specification: The ZCTR04 features a dual-row LED display for angle values and includes two buttons for mode and parameter adjustments. The back panel has 12 connection pins for power, communication, and alarm control.
Order Information: Part number ZCTR04. Specifications are subject to change without notice.
See more

Catalog excerpts

ZCTR04-1

ZCTR04 User Manual ZCTR04 Description: Description ZCTR04 is a display which researched for ZCT100-485 series 1-axis tilt sensor and used for display the current output angle value. The alarm angle can be set by user accordingly. When the angle returned is bigger than the alarm angle ,ZCTR04 will alarm with lighting and at the same time the relay inside closed and the external circuit is triggered to control. Technical data data: Parameter Operating Voltage Range Quiescent current Display Resolution Baud Rate Relay voltage of trigger Relay load ability Operating temperature Outline Size 1.PIN1:connect power anode. Shanghai Zhichuan Electronic Tech Co.,Ltd ADD:3/F,1128 Denghui Rd., Minhang district, Shanghai, 201109,China. TEL:+86-021-64908096 Http://www.zc-sensor.com E-mail:[email protected]

 Open the catalog to page 1
ZCTR04-2

2.PIN2:connect power GND; 3.PIN3:None 4.PIN4:None 5.PIN5:output power GND, public GND with ZCT245 series tilt sensor. 6.PIN6:output of power +5V,connect +5V power supply for ZCT245 series tilt sensor; 7.PIN7:connect 485A of ZCT100-485 series tilt sensor; 8.PIN8:connect 485B of ZCT100-485 series tilt sensor; 9.PIN9:Trigger A1-2 of relay A1, used for connect external circuit; 10.PIN10:Trigger A1-1 of relay A1, used with A1-2 to control external circuit; 11.PIN11:None; 12.PIN12:None; ZCTR04 connect ZCT100-485 series tilt sensor ZCTR04 connect ZCT100-485 ZCT100-485: Remark: 1. When connect ZCT100...

 Open the catalog to page 2
ZCTR04-3

Dividing resistor When the returned angle of ZCTR04 is smaller than the alarm angel the relay act none. The external circuit disconnect at this time. When the returned angle of ZCTR04 is bigger than the alarm angel the alarm light is on and the relay close to connect the external circuit. Attention: Please note the max voltage and max current support when use. Button operation instruction: Button definition: 1: MODE button: used for change major state and secondary state. There are 4 major states total as follows: state 0,state 1,state 2,state 3. And 3 secondary states: state 4, state 5, state...

 Open the catalog to page 3
ZCTR04-4

Operating instruction: Meanings of State0 to State6 are as follows: State 0: Default display angle value, display 00 when there are no any tilt sensor connected. State 1: Zero clearing to choose, Nixie tube show 11 ( the hind two of the upper 4 bits show "11", the hind two of the following 4 bits also show "11"). Under this model, you can enter into mode 4 by setting button to set relative Zero. State 2: Display alarm angle. The default value is 120 degree . Under this model, you can enter into mode 5 by setting button to set alarm angle. State 3: Display alarm angle. Under this model, you can...

 Open the catalog to page 4

All Shanghai Zhichuan Electronic Tech Co., Ltd catalogs and technical brochures

  1. ZCT-CX09

    10  Pages

  2. ZCT-CX300

    18  Pages

  3. ZCT190J-LPS-A

    3  Pages

  4. ZCT190AL-V1

    5  Pages

  5. ZCT181J-LMS

    3  Pages

  6. ZCT190J-SPS-A

    6  Pages

  7. ZCT175J-NMQ

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.