video corpo

ZCT1XXXJ-SXX-1907

ZCT1XXXJ-SXX-1907

ZCT1XXXJ-SXX-1907

Product catalog summary
General Description
ZCT160J-SQS-1907 is a single-axis inclinometer with a voltage output range of 1 to 4 Volts.
Features
  • Reliable and stable performance
  • Shockproof design
  • IP66 and CE certified
Applications
  • Industrial devices
  • Safe load indicators and boom angle measurement
  • Medical devices and mining machinery
Technical Parameters
  • Power Supply: 8-30 V (DC)
  • Work Current: 60-80 mA at 12V
  • Output Voltage Range: 1-4 V
  • Operating Temperature: -40 to +85 °C
  • Total Range: -60 to 60 degrees
  • Sensitivity: 25 mV/°
  • Resolution: 0.1°
  • Non-linearity: ±0.4 %/FS
  • Repeatability: ±0.2°
  • Zero Temperature Drift: 0.0067 °/°C
  • Housing Size: 100x50x30 mm

Note: Ensure power supply voltage is within the specified range to avoid damage or reduced lifespan.

Use Method
  1. Mount vertically with the cable towards the earth; angle increases when rotated clockwise.
  2. Angle calculation: (output voltage - zero output voltage) / sensitivity.
  3. Green lamp indicates power state.
Wiring and Mounting
  • Wiring: Brown - Power+, Black - Power-, Blue - Voltage Output
Order Information
  • Default cable length is 0.1m; specify if a different length is needed.
  • Includes Tyco connector and waterproof plug.

Specifications are subject to change without notice.

See more

Catalog excerpts

ZCT1XXXJ-SXX-1907-1

General description ZCT160J-SQS-1907 is single axis voltage output inclinometer , with output of 1~4Vol. Safe load indicator, boom angle measure Medical devices, mining machinery Shockproof IP66, CE certificated IV. Technical parameter Item Work temp Total range Power supply① Work current Output voltage range Zero temp drift Housing size ①:It must be ensured that the power supply voltage is within the specified range to make sure sensor work normally, if not, may cause product damage or shortened life. ②: Sensitivity is determined based on the output voltage range and the measurement angle range. Its definition is as follows:Vsens ={Vout(@max measuring angle)-Vout(@min measuring ange)}/{total range}, unit: [V/°] or [mV/°] Shanghai Zhichuan Electronic Tech Co.,Ltd Tel:021-64908093 64

 Open the catalog to page 1
ZCT1XXXJ-SXX-1907-2

③: Non-linearity refers to the deviation degree between the output curve and the best-fit line in the linear range. Use method 1.Cable toward to earth, vertical mounted, the angle is increased when rotary in CW direction. 2. Output and angle relationship: angle=(output voltage- zero output voltage)/ sensitivity; 3.The green lamp is for power state. 1. Wiring Brown: Power+; Black: Power-; Blue: voltage output 2. VII. Order info: 1. Default cable length is 0.1m, if other length cable required, please indicate in advance. 2. With tyco connector and waterproof plug. Specifications subject to change...

 Open the catalog to page 2

All Shanghai Zhichuan Electronic Tech Co., Ltd catalogs and technical brochures