ZC ZCT215M-LBS-ABUS-E3-4505 High Accuracy Dual axis Digital Inclinometer
13Pages

{{requestButtons}}

Catalog excerpts

ZC ZCT215M-LBS-ABUS-E3-4505 High Accuracy Dual axis Digital Inclinometer - 1

Tilt sensorSpecification

Open the catalog to page 1
ZC ZCT215M-LBS-ABUS-E3-4505 High Accuracy Dual axis Digital Inclinometer - 2

http://en.zc-sensor.com/ I. General Description ---------------------------------------1 VIII. Guarantee Card

Open the catalog to page 2
ZC ZCT215M-LBS-ABUS-E3-4505 High Accuracy Dual axis Digital Inclinometer - 3

Tilt sensor Specification ZCT215M-LBS-ABUS-E3-4505 .General description ZCT215M-LBS-ABUS-E3-4505 is 2 axis high accuracy digital inclinometer (RS485) which is researched and developed by Shanghai Zhichuan .Measuring range is +/-15°, with IP67 aluminum casing. II. Technical Parameter (all the below parameter are effective under room temperature (25°C)if no special circumstances)

Open the catalog to page 3
ZC ZCT215M-LBS-ABUS-E3-4505 High Accuracy Dual axis Digital Inclinometer - 4

Reamrk:Refresh time means the minimun renew time of the sensor’ s 2 axis value .Thus in ask-Answer command, it needs at least 30s after last output demand till next demand EMC Item Test level Unit Test Standard

Open the catalog to page 4
ZC ZCT215M-LBS-ABUS-E3-4505 High Accuracy Dual axis Digital Inclinometer - 5

V. Product size: (unit: mm)

Open the catalog to page 5
ZC ZCT215M-LBS-ABUS-E3-4505 High Accuracy Dual axis Digital Inclinometer - 6

VI. Communication Protocol 1. Data Frame Format: (8-bit data bits, 1-bit stop bit, non parity, the default rate 9600) Identification Data Length (Ibyte ) (Ibyte ) Address Code Command Word Data Field Check Sum (Ibyte) (Ibyte) (Ibyte) “7 Data format: 16 binary Identifier: fixed as 0x77 Data length:the length from data length to check sum(including check sum) Address code: Sensor address, default 0x00 Data field: when different command words, there would be different content and length. Check Sum: the sum of data length,address code,command word and data field . (take no account of carry bit)...

Open the catalog to page 6
ZC ZCT215M-LBS-ABUS-E3-4505 High Accuracy Dual axis Digital Inclinometer - 7

Answer command: Identification Data Length Address Code Comand Word Data Field Check Sum (Ibyte ) (Ibyte ) (Ibyte ) (Ibyte ) (4byte) CIbyte ) 2.3 Read X.Y axis angle value Send command: 77 04 00 04 08 Identification (Ibyte ) Answer command Identification Data Length Address Code Comand Word Data Field Check Sum (Ibyte ) (Ibyte ) (Ibyte ) (Ibyte) (12byte) CIbyte ) Remark: Data field is 12 bytes return angle value,divided into 3 groups each group is made of 1 sign bit and 3 compress BCD code .they are respectively as X axis ,Y axis and zero. For example:

Open the catalog to page 7
ZC ZCT215M-LBS-ABUS-E3-4505 High Accuracy Dual axis Digital Inclinometer - 9

Remark: default value is 0x02:9600 .After successfully re-set the communication rate each time ,the sensors will answer with the original baud rate ,and then change the device communication rate immediately .If want high baud rate output, need set the baud rate as 115200. 2.7 Set sensor's address. Send Command: 77 05 00 OF 0115 Remark: if the sensors used under networking condition,node address cannot be 0 ,and the node should be less than 32. 2.8 Check sensor's address Send Command: 77 04 00 IF 23 Answer command: 2.9 Set output angle format. Send Command: 77 05 00 OC 00 11

Open the catalog to page 9
ZC ZCT215M-LBS-ABUS-E3-4505 High Accuracy Dual axis Digital Inclinometer - 10

Identification Data Longth Address Code Command Word Data Field Check Sum (Ibyte) (Ibyte) (Ibyte) (Ibyte) (Ibyte) (Ibyte) Answer command: Remark: ® Default output format is Ask-Answer format © 5Hz means automatically output 5 data each second, and so with others. ® Because RS485 IS half duplex,when the the sensor automatically export the data ,maybe it cannot receive command in valid,you may need to send command in repeatedly for many times ,in this way,the product can receive the signal.So if you want to send command and receive the command correctly, we recommend you set the sensor in...

Open the catalog to page 10
ZC ZCT215M-LBS-ABUS-E3-4505 High Accuracy Dual axis Digital Inclinometer - 11

Answer command: Remark: Remark: Data field 8 bytes, they are respectively 2 floatthe front 4 bytes is the X axis' temperature, the behind 4 bytes is Y axis' temperature. When install the sensors .wrong action will cause big measurement error.please pay attention to the below: d):"2 faces"means the mounting faces of the sensors and the measured objects should completely cling to each other (the measured objects' mounting face should be as horizontal as possible), no angle allowed (for example angle "a" in Pic A .the right installation please refer to Pic B . ©: "2 lines" means the Axis Line...

Open the catalog to page 11
ZC ZCT215M-LBS-ABUS-E3-4505 High Accuracy Dual axis Digital Inclinometer - 12

http://en.zc-sensor.com/ Measuring range.Output type,Interface,Housing ,Cable,EMC IP degree can be customized ,for details please contact us . Specification subject to change without notice! Product Name: Tilt sensor_ Data of purchasing: Time limit of Guaranteeing: Company Purchasing:_ Record of mending: • Report Time: • Reasons of fault • Reporter; • Results of mending; Information of customer holding this Guarantee Card;_ Note: This card is the basis for user enjoying maintaining and upgrades service.

Open the catalog to page 12
ZC ZCT215M-LBS-ABUS-E3-4505 High Accuracy Dual axis Digital Inclinometer - 13

Shanghai Zhichuan Electronic Tech Co., Ltd. Address:3/F Compositive Building, No.1128 Denghui RD, Minhang Shanghai, China 0086-21-64908093 64908096 (T) 0086-21-64906992 (F) Postcode:201109

Open the catalog to page 13

All Shanghai Zhichuan Electronic Tech Co. catalogs and technical brochures

  1. ZCT-CX09

    10 Pages

  2. ZCT-CX300

    18 Pages

  3. ZCTR04

    4 Pages

  4. ZCT190AL-V1

    5 Pages

  5. ZCT181J-LMS

    3 Pages

  6. ZCT175J-NMQ

    4 Pages