I. General Description ZC-LCS05A is a leveling control system that researched and developed by Shanghai Zhichuan Electronic Co.,Ltd. Relay output. 6 axis sensor; Engineering machinery, agriculture machinery Including accelerometer, and measuring device, etc. With gyroscope IV. Technical parameters: (Typical values under room temperature 25°C, unless special marked.)
Open the catalog to page 1The leveling system is consisted of two parts: the control box and the sensor. There is a 4pin M12 connector on the sensor used to connect with the cable on control box. There are 3 cables on the control box; one with female M12 connector used to receive data from sensor, another 4pin cable for relay output that used to control the electron magnetic valve, the last 2pin cable is for power supply. 2. Switch on-off the control box After powered on, both the manual and automatic lamp on the control box light up for 0.1 second, which means the leveling system is powered on successfully. Press...
Open the catalog to page 2Ax > 5 ゜,K1 pull on and K2 cut off, K1 magnetic valve positive pole (BROWN) outputs power voltage, K2 magnetic valve positive pole(GREEN) without power voltage output; Ax<-5 ゜, K2 pull on and K1 cut off, K1 magnetic valve positive pole (BROWN) without power voltage output, K2 magnetic valve positive pole(GREEN) output power voltage .Until the sensor platform angle is adjusted to within ± 2 ゜, the relay stops action: that is, K1, K2 are off, K1, K2 magnetic valve positive pole output are high impedance state. (If the relay action direction with a reserve direction of the expected leveling...
Open the catalog to page 35) Set alarm angle This function is to set the relay’s activate angle. Adjust it properly to get alarm output at different angles. In the target angle set mode, short press SET button to enter alarm angle setting mode, the controller will display ‘A’ and the current alarm angle, default alarm angle is ±5 ゜, short press left key or right key to increase or decrease the alarm angle. Alarm angle should be smaller than cut-off angle, and bigger than the target angle. Due to the limitation of the sensor’s accuracy, during alarm angle setting, controller will change 1 ゜ step by step, to increase...
Open the catalog to page 42. Casing dimension drawing: 1) Dimension of controller 3. Installation method and measure direction: Attention: Sensor should be horizontally mounted, the measure direction should be parallel to X axis. Measure direction as follows: 4.Wiring definition: Controller wiring definition: 2 core cable
Open the catalog to page 5Wire colour ♦ Controller's M12 connector definition: ♦ Sensor's M12 connector wiring definition: This data sheet is for reference only. Subject to amend the specification without notice.
Open the catalog to page 6All Shanghai Zhichuan Electronic Tech Co. catalogs and technical brochures
-
ZCT330M1-LWP-AN-YKG
20 Pages
-
ZCT-CX09
10 Pages
-
ZCT-CX300
18 Pages
-
ZCTR04
4 Pages
-
ZCTXXXK-LPS-155
4 Pages
-
ZCT190J-LPS-A
3 Pages
-
ZCT190J-LNS-20
3 Pages
-
ZCT190AL-V1
5 Pages
-
ZCT181J-LMS
3 Pages
-
ZCT1XXX-LNX-140
3 Pages
-
ZCT2XXL-XXS-A-7X
9 Pages
-
ZCT1XXXJ-SXX-1907
2 Pages
-
ZCT190J-SPS-A
6 Pages
-
ZCT290RS-LPS-77
5 Pages
-
ZCT1000ML-S230
4 Pages
-
ZCT330Ex-SWP-N-YK
4 Pages
-
ZCT215L-SQS-A1B-1907
4 Pages
-
ZCT175J-NMQ
4 Pages
-
ZCT145KR-LQS-AH-6207
4 Pages
-
ZCT21B0J-LPS-A
4 Pages