Melt Pressure Transducer Model:PT124G-121T(Flexible stem) Description PT124G-121T Series Melt Pressure Transducer. It is with thermocouple , can measure the pressure and temperature in one point. This model adopts special construction and excellent alloy elastic membrane to reduce the thermal draft ,improve the accuracy, good anti-jamming performance andt built in 80% shunt calibration, it can match our N series pressure instrument also can match the pressure instrument or controller of other brand . It is suitable for pressure measuring and controlling in melt fluid medium, such as the plastic & polymer in the process equipments. Can replace Dynisco / Gefran /GP50 etc. international brand absolutely . Application Chemical fiber Equipment Plastic and Rubber manufacturing equipment Medicine & Food process equipment Measurement and Control all kinds of melt fluid Feature Stainless steel welding Easy to install Zero and span adjustable Various amplified signals optional Internal 80% shunt calibration Good stability and anti-jamming capability Excellent stability and repeatability can measure the pressure and temperature in one point
Open the catalog to page 1Melt Pressure Transducer Specification Pressure range: Output: Input voltage: Accuracy: Repeatability: Construction: Bridge resistance: Overload pressure: Internal shunt calibration: Insulation Resistance: Standard wetted Parts Mounting Torque Max. Diaphragm Temp: Electronic operating temperature: Electric connector: Rigid Length: Flexible Length: Thermocouple type: Process connection: Mounting Hole 45° Slope Sealed Ordering Guide Model Rigid & flexible length (inch) Screw Thread Electric connection Thermo Type
Open the catalog to page 2Operating instruction Attention for installation 1, Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole. Install with aluminum gasket. The electronics housing should be secured, with the enclosed mounting bracket. 2, Remove Make sure that there is no remained metal or plastic; remove all of the transducers from the equipment before you clean the extruder. You can remove the transducer only when the polymer is molten. And clean the diaphragm of the transducer with soft cloth as soon as you remove it. At...
Open the catalog to page 3Melt pressure transducer Wiring diagram Output Calibration Output Shanghai Zhaohui Pressure Apparatus Co., Ltd 5-6F No.8 Building No.115 ,Lane 1276 Nanle Road Songjiang District Shanghai 201600 China Tel:+86-21-51691919 67755189 Fax:+86-21-67755185 E-mail: info@zhyqsensor.com www.zhyqsensor.com ZHYQ sensor & control
Open the catalog to page 4All Shanghai Zhaohui Pressure Apparatus Co. catalogs and technical brochures
-
Bolt Burst Plug
1 Pages
-
SIL Certificate
1 Pages
-
ROHS Certificate
1 Pages
-
CE Certificate
1 Pages
-
ISO Certificate
1 Pages
-
ATEX certificate
1 Pages