1. Catalogs
  2. Shanghai Zhaohui Pressure Apparatus Co.,Ltd.(ZHYQ)
  3. ZHYQ PT124G-112 high accuracy rigid melt pressure transducer for plastic extruder

ZHYQ PT124G-112 high accuracy rigid melt pressure transducer for plastic extruder

ZHYQ PT124G-112 high accuracy rigid melt pressure transducer for plastic extruder

ZHYQ PT124G-112 high accuracy rigid melt pressure transducer for plastic extruder

Product catalog summary
Overview
The PT124G-112/112T Series Melt Pressure Transducer is designed for high accuracy pressure and temperature measurement in melt fluid mediums, such as plastics and polymers. The PT124G-112T model includes a thermocouple for simultaneous pressure and temperature readings. It features a special construction with an alloy elastic membrane to minimize thermal drift and enhance accuracy. The transducer is compatible with various pressure instruments and controllers, including those from other brands.

Applications
  • Fiber Equipment
  • Plastic and Rubber Manufacturing Equipment
  • Chemical Fiber and Polyester Process Equipment
  • General Melt Pressure Measurement and Control

Features
  • High accuracy and stability
  • Stainless steel construction
  • Easy installation
  • Internal 80% calibration
  • Excellent repeatability

Specifications
  • Pressure Range: 0 to 3.5MPa up to 150MPa
  • Output: 2mV/V or 3.33mV/V
  • Input Voltage: 10V DC (range 6-12V)
  • Accuracy: ±0.25% FSO or ±0.5% FS
  • Repeatability: ±0.2% FSO
  • Construction: Wheatstone bridge
  • Bridge Resistance: Input 345 Ohms minimum, Output 350 Ohms ±10%
  • Overload Pressure: 1.5 times FSO
  • Insulation Resistance: 200 Megohms @ 100Vdc
  • Max Diaphragm Temperature: 0 to 400℃
  • Operating Temperature: -25℃ to 85℃
  • Electric Connector: 6PIN
  • Thermocouple Types: J, K, E, PT100 (optional for PT124G-112T)

Installation and Maintenance
  1. Ensure correct machining of the mounting hole before installation. Use an aluminum gasket and secure the electronics housing with the provided bracket.
  2. Remove transducers only when the polymer is molten and clean the diaphragm with a soft cloth immediately after removal.
  3. Allow sufficient soak time to ensure material at the transducer tip is molten before starting the process.
  4. Keep the electrical housing at room temperature to maintain accuracy and prolong the transducer's life.
  5. Avoid prolonged overload pressure to prevent accuracy degradation and reduced lifespan.
  6. Use shielded cables and ground the cable shield at one end to prevent interference.

Wiring Diagram
The wiring diagram specifies the color coding for connections: Signal + (Blue), Signal - (Green), Excitation + (Red), Excitation - (Yellow), Calibration (Brown and Black).
See more

Catalog excerpts

ZHYQ PT124G-112 high accuracy rigid melt pressure transducer for plastic extruder-1

Melt Pressure Transducer Model:PT124G-112/112T(Rigid High precision) Description PT124G-112/112T Series Melt Pressure Transducer(rigid stem & High accuracy ). The model PT124G-112T with thermocouple can measure the pressure and temperature in one point. This model adopts special construction and excellent alloy elastic membrane to reduce the thermal draft ,improve the accuracy, good anti-jamming performance andt built in 80% shunt calibration, it can match our N series pressure instrument also can match the pressure instrument or controller of other brand . It is suitable for pressure measuring and controlling in melt fluid medium, such as the plastic & polymer in the process equipments. Can replace Dynisco / Gefran /GP50 etc. international brand absolutely . Application Fiber Equipment Plastic and Rubber manufacturing equipment Chemical fiber, polyester process equipment Other melt pressure measurement and Control Feature High accuracy Stainless steel welding Easy to install Internal 80% calibration Excellent stability and repeatability Φ37.5

 Open the catalog to page 1
ZHYQ PT124G-112 high accuracy rigid melt pressure transducer for plastic extruder-2

Melt Pressure Transducer Specification Pressure range: Output: Input voltage: Accuracy: Repeatability: Construction: Bridge resistance: Overload pressure: Internal shunt calibration: Insulation Resistance: Standard wetted Parts Mounting Torque Max. Diaphragm Temp: Electronic operating temperature: Electric connector: Thermocouple type: Process connector: Mounting hole 45°Slope Sealed Ordering Guide Model Screw Thread Electric connection Other requirement ---

 Open the catalog to page 2
ZHYQ PT124G-112 high accuracy rigid melt pressure transducer for plastic extruder-3

Operating instruction Attention for installation 1, Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole. Install with aluminum gasket. The electronics housing should be secured, with the enclosed mounting bracket. 2, Remove Make sure that there is no remained metal or plastic; remove all of the transducers from the equipment before you clean the extruder. You can remove the transducer only when the polymer is molten. And clean the diaphragm of the transducer with soft cloth as soon as you remove it. At the...

 Open the catalog to page 3
ZHYQ PT124G-112 high accuracy rigid melt pressure transducer for plastic extruder-4