1. Catalogs
  2. Shanghai Zhaohui Pressure Apparatus Co.,Ltd.(ZHYQ)
  3. ZHYQ PT124B-111T rigid melt pressure transmitter for plastic extruder

ZHYQ PT124B-111T rigid melt pressure transmitter for plastic extruder

ZHYQ PT124B-111T rigid melt pressure transmitter for plastic extruder

ZHYQ PT124B-111T rigid melt pressure transmitter for plastic extruder

Product catalog summary
Overview
The PT124B-111 T Series Melt Pressure Transducer is designed to measure both pressure and temperature at a single point, equipped with a thermocouple. It is compatible with the PY Series Intelligent Digital Pressure Instrument from ZHYQ or other brands. The transducer features adjustable zero and full span, amplified signal output for PLC connection, high precision, reliable pressure measurement, and internal 80% calibration.

Applications
  • Chemical fiber equipment
  • Plastic and rubber manufacturing equipment
  • Measurement and control of various melt fluids

Features
  • High-standard quality with stainless steel seal
  • Simple installation and 80% inner calibration
  • Excellent stability and repeatability
  • Capability to measure pressure and temperature at one point

Specifications
  • Pressure range: 0 to 3.5MPa up to 150MPa
  • Output options: 0~5V, 0~10V, 4-20mA
  • Input voltage: 24V DC (range 12~36V)
  • Accuracy: ±1.0%FS or ±1.5%FS
  • Repeatability: ±0.2% FSO
  • Construction: Wheatstone bridge with input resistance of 345 Ohms minimum and output resistance of 350 Ohms ±10%
  • Overload pressure: 1.5 times FSO
  • Internal shunt calibration: 80% ±1%
  • Insulation resistance: 200 Megohms @100Vdc
  • Max diaphragm temperature: 0~400℃
  • Electronic operating temperature: -25℃ to 85℃
  • Electric connector options: 5PIN or 6PIN
  • Thermocouple types: J, K, E, PT100 (optional)
  • Process connector options: 1/2″-20UNF, M14×1.5, M18×1.5

Installation and Maintenance
  1. Ensure correct machining of the mounting hole before installation. Use an aluminum gasket and secure the electronics housing with the provided bracket.
  2. Remove transducers only when the polymer is molten and clean the diaphragm with a soft cloth.
  3. During start-up, ensure the system reaches operating temperature and follow procedures for zero and span adjustment.
  4. Keep the transducer shell at room temperature to maintain accuracy and prolong life.
  5. Avoid prolonged overload pressure to prevent accuracy degradation.
  6. Use shielded cables and ground the cable shield at one end to prevent interference.

Wiring Instructions
  • 5PIN and 6PIN configurations are provided for different output functions, with specific color coding for signal and excitation connections.

Contact Information
Shanghai Zhaohui Pressure Apparatus Co., Ltd, located in Songjiang District, Shanghai, China. Contact via phone or email for further inquiries.
See more

Catalog excerpts

ZHYQ PT124B-111T rigid melt pressure transmitter for plastic extruder-1

Melt Pressure Transmitter Model:PT124B-111T (Standard type) Description PT124B-111 T Series Melt Pressure Transducer can measure the pressure and temperature at one point. It is with thermocouple. This series can be used together with the PY Series Intelligent Digital Pressure Instrument of ZHYQ or other brand instrumentation. Zero & full span can be adjustable, with amplify signal can be connected with PLC. With the advantage of high precision and reliable pressure measuring and good quality, internal 80% calibration and etc. Application    Chemical fiber Equipment Plastic and Rubber manufacturing equipment Measure and Control all kinds of melt fluid High-standard quality Stainless steel Seal Simple Installation 80% inner calibration Excellent stability and repeatability Can measure the pressure and temperature in one point ZHYQ sensor

 Open the catalog to page 1
ZHYQ PT124B-111T rigid melt pressure transmitter for plastic extruder-2

Melt Pressure Transmitter Specification Pressure range: Output: Input voltage: Accuracy: Repeatability: Construction: Bridge resistance: Overload pressure: Internal shunt calibration: Insulation Resistance: Standard wetted Parts Mounting Torque Max. Diaphragm Temp: Electronic operating temperature: Electric connector: Rigid Length Thermocouple type: Process connector: Mounting hole 45° Slope Sealed Ordering Guide Model Rigid length (inch) Screw Thread Electric connection Thermo type

 Open the catalog to page 2
ZHYQ PT124B-111T rigid melt pressure transmitter for plastic extruder-3

Operating instruction Attention for installation 1, Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole. Install with aluminum gasket. The electronics housing should be secured, with the enclosed mounting bracket. 2, Remove Make sure that there is no remained metal or plastic; remove all of the transducers from the equipment before you clean the extruder. You can remove the transducer only when the polymer is molten. And clean the diaphragm of the transducer with soft cloth as soon as you remove it. At the...

 Open the catalog to page 3
ZHYQ PT124B-111T rigid melt pressure transmitter for plastic extruder-4

Melt pressure transmitter Wiring diagram Output Calibration Output Calibration Output Shanghai Zhaohui Pressure Apparatus Co., Ltd 5-6F No.8 Building No.115 ,Lane 1276 Nanle Road Songjiang District Shanghai 201600 China Tel:+86-21-51691919 67755189 Fax:+86-21-67755185 E-mail: [email protected] www.zhyqsensor.com ZHYQ sensor & control

 Open the catalog to page 4

All Shanghai Zhaohui Pressure Apparatus Co.,Ltd.(ZHYQ) catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.