The PT124G-122T Series Melt Pressure Transducer is equipped with a thermocouple for simultaneous pressure and temperature measurement. It is widely used in medicine, food processing equipment, and environmental monitoring of drinking water. This model is known for its precision, reliability, and high-quality standards.

Applications
  • Chemical fiber equipment
  • Plastic and rubber manufacturing equipment
  • Medicine and food processing equipment
  • Drinking water environmental monitoring
  • General pressure measurement and control

Features
  • Stainless steel construction
  • Easy installation
  • Adjustable zero and span
  • Optional amplified signals
  • Internal 80% shunt calibration
  • Good stability and anti-jamming capability
  • Excellent stability and repeatability

Specifications
  • Pressure Range: 0 to 150 MPa (0 to 20000 psi)
  • Output: 2mV/V; 3.33mV/V
  • Accuracy: ±1% FS
  • Excitation: 10VDC
  • Repeatability: ±0.2%
  • Construction: Wheatstone bridge
  • Bridge resistance: 350 ohms ±10%
  • Overload pressure: 1.5×FSO
  • Internal calibration: 80% ±1%
  • Insulation Resistance: 1000 Megohms @50Vdc
  • Max Diaphragm Temp: 0~260℃
  • Thermocouple type: J, K, E, PT100 (optional)
  • Electric connector: 5PIN, 6PIN
  • Process connector: 1/2″-20UNF, M14×1.5, M18×1.5 (customizable)

Installation and Operation
  1. Do not remove the protective cap until installation. Verify the mounting hole and use an aluminum gasket. Secure the electronics housing with the provided bracket.
  2. Ensure no metal or plastic remains when removing the transducer. Clean the diaphragm with a soft cloth and use the ZHYQ cleaning tool kit for the mounting hole.
  3. Allow sufficient soak time for the transducer tip to reach operating temperature before starting the process.
  4. The transducer tip can withstand high temperatures, but the shell should remain below 80℃ to maintain accuracy and longevity.
  5. Avoid overloading the transducer beyond its rated pressure to prevent accuracy degradation and reduced lifespan.
  6. Use shielded cables and ground the cable shield at one end to prevent interference.

Wiring Diagrams
Detailed wiring diagrams are provided for various output functions and connector types (5PIN, 6PIN, 8PIN) to ensure proper installation and operation.
See more

Catalog excerpts

ZHYQ Melt pressure tranducer PT124G-122/122T food machine-1

Melt Pressure Transducer Model:PT124G-122T(Sanitary type) Description PT124G-122T Series Melt Pressure Transducer comes with thermocouple, it can achieve the pressure and temperature measuring and has the wide application in Medicine & Food process equipment, drinking water environmental monitoring. The model PT124G-122T is with temperature-measuring transducer. It has the wide application in China, with the advantage of precision and reliable pressure measuring and high-standard quality. Application  Chemical fiber Equipment  Plastic and Rubber manufacturing equipment  Medicine & Food process equipment ,  Drinking water environmental monitoring occasion  Other pressure measurement and Control Feature  Stainless steel welding  Easy to install  Zero and span adjustable  Various amplified signals optional  Internal 80% shunt calibration  Good stability and anti-jamming capability  Excellent stability and repetition ZHYQ Sensor & Control

 Open the catalog to page 1
ZHYQ Melt pressure tranducer PT124G-122/122T food machine-2

Melt Pressure Transducer rlZHYQ Specification Ordering Guide Shanghai Zhaohui Pressure Apparatus Co., Ltd 5-6F No.8 Building No.115 ,Lane 1276 Nanle Road Songjiang District Shanghai 201600 China Tel:+86-21-51691919 67755189 Fax:+86-21-67755185 . _^ ZHYQ Sensor & Control

 Open the catalog to page 2
ZHYQ Melt pressure tranducer PT124G-122/122T food machine-3

Melt pressure transducer/transmitter Operating instruction Attention for installation 1, Installation Do not remove protective cap until ready to install. Prior to initial installation, verify correct machining of mounting hole. Install with aluminum gasket. The electronics housing should be secured, with the enclosed mounting bracket. 2, Remove Make sure that there is no remained metal or plastic; remove all of the transducers from the equipment before you clean the extruder. You can remove the transducer only when the polymer is molten. And clean the diaphragm of the transducer with soft cloth...

 Open the catalog to page 3
ZHYQ Melt pressure tranducer PT124G-122/122T food machine-4

Wiring diagram Shanghai Zhaohui Pressure Apparatus Co., Ltd 5-6F No.8 Building No.115 ,Lane 1276 Nanle Road Songjiang District Shanghai 201600 China Tel:+86-21-51691919 67755189 Fax:+86-21-67755185 E-mail: [email protected] www.zhyqsensor.com

 Open the catalog to page 4

All Shanghai Zhaohui Pressure Apparatus Co.,Ltd.(ZHYQ) catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.