video corpo

110

110

Product catalog summary

Overview

This document provides detailed specifications for RCCN non-insulated ring terminals compliant with RoHS standards. These terminals are designed for electrical connections with various wire sizes and bolt dimensions, primarily used in American standard applications.

Product Specifications

The ring terminals are categorized based on the electrical wire cross-sectional area (electric square) and corresponding American Wire Gauge (AWG) sizes, with maximum current ratings specified for each category:

  • 95–120 mm² (AWG 3/0) with a max current of 255A
  • 70–95 mm² (AWG 2/0) with a max current of 235A
  • 50–70 mm² (AWG 1/0) with a max current of 215A
  • 120–150 mm² (AWG 4/0) with a max current of 300A

Dimensional Data and Bolt Compatibility

The terminals are specified with dimensions including bolt hole diameter (dφ), outer diameter (Dφ), length (L), width (B), flange (F), and thickness (E). These dimensions vary according to the bolt size and terminal model number. The bolt sizes correspond to American bolt numbers such as 1/4", 5/16", 3/8", 1/2", 9/16", 5/8", 11/16", and 3/4".

Examples of terminal models and dimensions include:

  • R60 Series (95–120 mm²): Bolt sizes from 1/4" to 3/4", length around 49.7 mm, width 22.0 or 32.0 mm, with bolt hole diameters ranging from 6.5 mm to 21.0 mm.
  • R80 Series (70–95 mm²): Similar bolt sizes with lengths approximately 54.2 to 68.0 mm and widths 22.0 or 32.0 mm.
  • R70 and R100 Series (120–150 mm²): Larger dimensions with lengths from 51.2 mm to 69.0 mm and widths 20.0 to 32.0 mm.

Electrical and Mechanical Parameters

  • Maximum current ratings range from 215A to 300A depending on wire size.
  • Bolt hole diameters are matched to standard American bolt sizes to ensure compatibility.
  • Dimensions are provided to assist in proper selection and installation.

Recommendations and Usage

These non-insulated ring terminals are suitable for high-current electrical connections where insulation is not required. Proper matching of terminal size to wire gauge and bolt size is critical to ensure electrical safety and mechanical stability.

Users should verify the maximum current rating and dimensional compatibility with their application requirements.

See more

All Shanghai Richeng Electronics catalogs and technical brochures

  1. RCCN Catalogue

    393  Pages

  2. BL-EMC

    1  Page

  3. 2016 catalogue

    24  Pages

  4. Snap Rivet

    1  Page

  5. Wire Terminals

    16  Pages

  6. Wire Terminals

    22  Pages

  7. DIN Rails

    8  Pages

  8. Wiring Duct

    36  Pages

  9. Wire Connectors

    10  Pages

  10. Twist Ties

    8  Pages

  11. Cable Tie

    19  Pages

  12. Wire Conduits

    33  Pages

  13. BGE End Cap

    1  Page

  14. B-

    19  Pages

  15. 125

    1  Page

  16. 124

    1  Page

  17. 123

    1  Page

  18. 122

    1  Page

  19. 121

    1  Page

  20. 120

    1  Page

  21. 119

    1  Page

  22. 118

    1  Page

  23. 117

    1  Page

  24. 116

    1  Page

  25. 115

    1  Page

  26. 114

    1  Page

  27. 113

    1  Page

  28. 112

    1  Page

  29. 111

    1  Page

  30. 109

    1  Page

  31. 108

    1  Page

  32. 107

    1  Page

  33. 106

    1  Page

  34. 105

    1  Page

  35. 104

    1  Page

  36. 103

    1  Page

  37. 102

    1  Page

  38. 101

    1  Page

  39. 100

    1  Page

  40. 99

    1  Page

  41. 98

    1  Page

  42. 97

    1  Page

  43. 96

    1  Page

  44. 95

    1  Page

  45. 94

    1  Page

  46. 93

    1  Page

  47. 92

    1  Page

  48. 91

    1  Page

  49. 90

    1  Page

  50. 89

    1  Page

  51. 88

    1  Page

  52. 87

    1  Page

  53. 86

    1  Page

  54. 85

    1  Page

  55. 84

    1  Page

  56. 83

    1  Page

  57. 82

    1  Page

  58. 81

    1  Page

  59. 80

    1  Page

  60. 79

    1  Page

  61. 78

    1  Page

  62. 77

    1  Page

  63. 75

    1  Page

  64. 74

    1  Page

  65. 73

    1  Page

  66. 72

    1  Page

  67. 71

    1  Page

  68. 70

    1  Page

  69. 69

    1  Page

  70. 68

    1  Page

  71. 67

    1  Page

  72. 66

    1  Page

  73. 65

    1  Page

  74. 64

    1  Page

  75. 63

    1  Page

  76. 62

    1  Page

  77. 61

    1  Page

  78. 60

    1  Page

  79. 59

    1  Page

  80. 58

    1  Page

  81. 57

    1  Page

  82. 56

    1  Page

  83. 55

    1  Page

  84. 54

    1  Page

  85. 53

    1  Page

  86. 52

    1  Page

  87. 51

    1  Page

  88. 50

    1  Page

  89. 49

    1  Page

  90. 48

    1  Page

  91. 47

    1  Page

  92. 46

    1  Page

  93. 45

    1  Page

  94. 44

    1  Page

  95. 43

    1  Page

  96. 42

    1  Page

  97. 41

    1  Page

  98. 40

    1  Page

  99. 39

    1  Page

  100. 38

    1  Page

  101. 37

    1  Page

  102. 36

    1  Page

  103. 35

    1  Page

  104. 34

    1  Page

  105. 33

    1  Page

  106. 32

    1  Page

  107. 31

    1  Page

  108. 30

    1  Page

  109. 29

    1  Page

  110. 28

    1  Page

  111. 27

    1  Page

  112. 26

    1  Page

  113. 25

    1  Page

  114. 23

    1  Page

  115. 22

    1  Page

  116. 21-2

    1  Page

  117. 21

    1  Page

  118. 20

    1  Page

  119. 19

    1  Page

  120. 18

    1  Page

  121. 17

    1  Page

  122. 16B

    1  Page

  123. 16A

    1  Page

  124. 16

    1  Page

  125. 15

    1  Page

  126. 14

    1  Page

  127. 13

    1  Page

  128. 12

    1  Page

  129. 11

    1  Page

  130. 10

    1  Page

  131. 9

    1  Page

  132. 8

    1  Page

  133. wire duct

    1  Page

  134. cable duct

    1  Page

  135. wiring duct

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.