Products description and application ZEN7e LED Light,using aluminum alloy as the lamp body, lightweight design provides reliable and energy-saving lighting solutions. It is applied for the indoor lighting of wind turbines, towers and nacelles and a supplementary lighting of indoor application. Compliant to: IEC60598-2-5\IEC60068-2\IEC60529\IEC62262\EN55015 Certified to: UL Features With high light efficiency and stability: It provides the high light efficacy and superb industrial stability by combining the leading LEDs and LED drivers. Tempered glass lighting cover for anti-aging. Long lifespan and environmental friendly: The LED fixtures have a lifespan above 50,000hrs and save at least 50% energy and free of maintenance. Compact and light structure, adjustable mounting bracket for easy site installation Simple and convenient wire connection. Emergency test switch: The emergency function can be tested once installation. It also have the switch-over function The battery can be replaceable. Emergency function:90 minutes emergency time Battery automatic maintenance function: The lamp needs to be charged and discharged once every three months. In the case of continuous power for three consecutive months, the lamp will automatically perform one charge and discharge without manual maintenance. Automatic detection function: When the lamp fails, the status indicator shows a red light flashing to remind. Battery indicator function: When the lamp is charging, the status indicator is flashing green to indicate the battery level. General Specifications Electrical parameters Operating voltage AC120V~AC277V Power frequency 50Hz~60Hz Rated power 30W Power factor Electromagnetic Compatibility Relative humidity Emergency duration Charging time Mechanical parameters Body material Aluminum Cover material Tempered glass Storage -40˚C ~ +60˚C temperature Operating -40˚C ~ +60˚C temperature (Non-emergency) -30˚C ~ +50˚C(Emergency) IP rate IEC60529 IP65 IEC60068-2-6 3G Anti-vibration IEC62262 IK05 IK Rate ISO9227 C4 Anti-c
Open the catalog to page 1Optical parameter Lifespan Color temperature LED efficiency CRI Total lumens Emergency lumens Figure 2-1 Installation Method: Ensure that the supply voltage matches the rated voltage of the fixture. Fix it on the mounting surface with 2 nos or 4 nos M5 screws. The mounting surface should have enough mechanical strength and smoothness. Installation height is not limited. Place the bolts, washers and nuts according to the schematic diagram and tighten the two bol
Open the catalog to page 2Wiring Diagram Terminal block Figure 3-1 Figure 3-3 Figure 3-4 Wiring step: 1. Remove the 4 screws using cross recessed screwdriver, pull out the side cover to expose the terminal, as shown in Figure 3-1. 2. Pass the lead wire through the cable gland, the outer diameter of the cable should be φ8-14mm. 3. Use a small flat-blade screwdriver to insert a small square hole in the terminal block (Figure 3-3), to make the spring in the lower round hole pop open. 4. Connect the four single-core cables into the terminal block according to Figure 3-3 , then pull out the screwdriver and ensure the...
Open the catalog to page 3It is normal that the lamp has a temperature rise during operation. Before working, please confirm whether the working voltage is within the range. Overvoltage will damage the product and pose a safety hazard. When installing the wiring, please connect it accurately according to the wiring diagram to prevent short circuit. After the installation, please confirm the single core wire cannot be pulled out. Do not open any part of the lamp in order to avoid any danger when it works. As it is sealed structure, do not disassemble the lamp without professional people. Otherwise, the warranty is...
Open the catalog to page 4All Shanghai Nanhua Electronics Company catalogs and technical brochures
-
WPM Series Modular LED Light
6 Pages
-
LW34/LW34L LED Linear Light
4 Pages
-
LF22 High Bay Light
4 Pages
-
LF43 Series LED Flood Light
3 Pages
-
FAR Ultrasonic Wind Sensor
4 Pages
-
BC-8 Audible Visual Alarm
8 Pages
-
AL120 Audible Visual Alarm
9 Pages
-
TW101 Intercom System
2 Pages
-
ZD402Power Supply Cabinet
5 Pages
-
ABC-7A
1 Pages
-
ABC-7L
2 Pages
-
LS310
2 Pages
-
AL110U
2 Pages
-
AL80
2 Pages
-
AL07S Tower signal
3 Pages
-
ABC-401
1 Pages
-
LM100
4 Pages
-
LP1X Ex LED Area light
2 Pages
-
LP201A Helideck Status Light
2 Pages
-
LP4Circle-H Helideck Light
3 Pages
-
HD301A Platform edge light
1 Pages
-
SL301A LED light
1 Pages
-
LW24XX
2 Pages
-
LY455B Emergency LED Light
2 Pages
-
LY455LED Linear Light
1 Pages
-
LF21LED Flood Light
4 Pages
-
LF30Series
5 Pages
-
LF43 Series
4 Pages
-
LF23
3 Pages
-
LF22
4 Pages
-
LW15 LED Work Light
3 Pages
-
LF70H LED Flood Light
4 Pages
-
AL001
1 Pages
-
BC-3B
1 Pages
-
AL600U
2 Pages
-
BC-110
1 Pages
-
AL310
3 Pages
-
BC-2
2 Pages
-
AS210
3 Pages
-
AS201A
2 Pages
-
LH88
16 Pages
-
LT602U
2 Pages
-
LT601U
2 Pages
-
LT101
2 Pages
-
LQ006U
1 Pages
-
BC-60
1 Pages
-
DT00
6 Pages
-
Wind Speed Sensor FA01
5 Pages
-
ZD402
2 Pages
-
TW101
2 Pages
-
LT864
5 Pages
-
LM40
6 Pages
-
LM101+LM212
2 Pages
-
LM101
1 Pages
-
LM403
4 Pages
-
LS810D
2 Pages
-
LS730U
1 Pages
-
LS710
2 Pages
-
LS31X-E1-V10
2 Pages
-
Wind power generation
11 Pages
-
Catalogue - port application
32 Pages
-
Aviation obstruction light
40 Pages
-
LF70 HIGH MAST LED LIGHTING
8 Pages