ZD402Power Supply Cabinet
5Pages

{{requestButtons}}

Catalog excerpts

ZD402Power Supply Cabinet - 1

ZD402Power Supply CabinetProducts description and applicaiton Designed as power supply for use in towers (power transmission, telecommunication, microwave), chimney (power plant, coking plant, chemical plant), high buildings, large bridges, large port machinery, large engineering machinery, wind turbines. Features • Industrial standard design, suitable for use in harsh industrial environments. • Multi protection design: Short circuit/Over current/Overvoltage. • Built-in UPS, automatic change to battery power when main power is off. • Product has power failure alarm function, when main power failed or battery low, product’s power failure indicator lit up and output alarm signal. • Product has UPS battery activation function. • Failure alarm signal is dry contact(relay/passive) output. • Built-in heating and temperature control module, automatic start to heat while low temperature, prevent to impact the performance when product is in low temperature. Rated power consumption Battery capacity Lightning surge Electrostatic discharge EMC Mechnical Material Color Storage temperature Operating temperature IP Rate Weight Cold rolled plate + powder coated Gray (RAL7038> -40°C~+60°C -40°C~+55°C IEC60529 IP54 87 kg Mounting dimensions Ensure mount face or mount bracket has enough mechanical strength, and mount place has enough space, product junction box cover could be opened. Fix product by using four sets M10 screws. Caution: Use stainless steel screws to fix product. Connect power line through the cable gland, refer terminals labels to correctly connect the power wires, fasten the cable gland when finish the wiring connection. Ensure the input voltage is correct. Storage temperature: -40°C~60°C. Discharge and charge the battery every 6 months if the product storage time is over 6 month. Caution: Do not close the circuit-beaker when connect the main power, the circuit-breaker can be closed after wiring connected. Caution: Do not touch electrical parts while product is operating.

Open the catalog to page 1
ZD402Power Supply Cabinet - 2

Wiring diagram 接线示意图 Wiring diagram N Battery undervoltage alarm AC power failure alarm Light1~2 Alarm Light1 Alarm Output Input

Open the catalog to page 2
ZD402Power Supply Cabinet - 3

ZD402Power Supply Cabinet Introduction: • When battery activation start, high-level (24VDC) duration is not less than 0.5S, correspond with electrical symbol 011 (positive), 013 (naegative). • Battery low voltage alarm: Normal operation is Normal Open, Failure is Close, correspond with electrical symbol 001,003. • AC No-voltage alarm: Normal operation is Normal Open, Failure is Close, correspond with electrical symbol 005, 007. • Light 1~2 failure alarm: Normal work is close, failed or no power is Normal Open (light1 and light2 failure alarm is parallelconnection, output through COM, NO)...

Open the catalog to page 3
ZD402Power Supply Cabinet - 4

ZD402Power Supply Cabinet • Activation button, press the button one time to start the activation, charge and activation indicator on, battery discharge to load and discharge resistor; press activation off button to stop activation, otherwise main power automatic complete battery activation. • Battery button, in the first use before battery has input, press battery on button, • Product start to operate when connect to main power, it is constant voltage and constant current charging for battery. When battery charging finish, power automatic turn to floating charge, power supply floating...

Open the catalog to page 4
ZD402Power Supply Cabinet - 5

ZD402Power Supply Cabinet If battery floating charge for a long term, start up battery activation to prevent battery polarity passivation. Discharge and charge the battery every 6 months if the product storage time is over 6 month. Press activation on button(or remote control) on charging module MBP to start activation , battery discharge and supply power to load, when battery discharge or activation is completed, main power automatic start to supply power to load and charge battery. If need to stop the activation, press activation off button to quit. Judging Battery Life method Battery...

Open the catalog to page 5

All Shanghai Nanhua Electronics Company catalogs and technical brochures

  1. ABC-7A

    1 Pages

  2. ABC-7L

    2 Pages

  3. LS310

    2 Pages

  4. AL110U

    2 Pages

  5. AL80

    2 Pages

  6. ABC-401

    1 Pages

  7. LM100

    4 Pages

  8. LW24XX

    2 Pages

  9. LF30Series

    5 Pages

  10. LF43 Series

    4 Pages

  11. LF23

    3 Pages

  12. LF22

    4 Pages

  13. AL001

    1 Pages

  14. BC-3B

    1 Pages

  15. AL600U

    2 Pages

  16. BC-110

    1 Pages

  17. AL310

    3 Pages

  18. BC-2

    2 Pages

  19. AS210

    3 Pages

  20. AS201A

    2 Pages

  21. LH88

    16 Pages

  22. LT602U

    2 Pages

  23. LT601U

    2 Pages

  24. LT101

    2 Pages

  25. LQ006U

    1 Pages

  26. BC-60

    1 Pages

  27. DT00

    6 Pages

  28. ZD402

    2 Pages

  29. TW101

    2 Pages

  30. LT864

    5 Pages

  31. LM40

    6 Pages

  32. LM101+LM212

    2 Pages

  33. LM101

    1 Pages

  34. LM403

    4 Pages

  35. LS810D

    2 Pages

  36. LS730U

    1 Pages

  37. LS710

    2 Pages

  38. LS31X-E1-V10

    2 Pages