Catalog excerpts
WPM Series Modular LED Light Products description and application Applied to the internal lighting system of wind turbines (cabin, tower, nacelle). Applied to the auxiliary lighting for indoor environment. Standard:: IEC61000-4\IEC60068-2\IEC60529\IEC62262\EN55015 Features Long lifetime LED source, energy saving and environmental protection. Soft light beam, no glare, no flicker. Spherical or elliptic light distribution curve. Wide input voltage . Electromagnetic compatibility. Constant current drive, maintenance-free. Meet emergency lighting application requirements. Suitable for extreme temperature. Light weight design, corrosion resistance, anti - aging. Shock resistance and vibration resistance. Modular design, each module can be freely combined to meet different application requirement. Multiple installation methods. General Specifications Electric parameter Working voltage Frequency Rated power EMC Mechanical parameter_ Housing ABS+PC Vibration Anti-corrosion Color Weight Working temperature Storage temperature Installation method Magnet/Hoisting/Wall-mounting Wiring method Cable gland/connector Optical parameter Light source LED Color temperature Cold white:5500K~6000K
Open the catalog to page 1WPM Series Modular LED Light Mounting dimensions l.Magnetic mounting(unit:mm): Use magnet to fix lamp to the installation plane directly. Note: the picture on the left shows the installation size of a single module, and the picture on the right shows the installation size of the combination of two modules. Note: the picture on the left shows the installation size of a single module, and the picture on the right shows the installation size after the combination of two modules. Multi - module mounting size accumulates successively.
Open the catalog to page 2(3) Beam angle C: 120°*120° 3. Spare parts selection table WPM-© spare parts for mounting PJ1: Magnetic mounting PJ2: M8 fixed mounting PJ3: M10 fixed mounting PJ4: Adjustable mounting PJ5: Direct mounting PJ6: Combination parts WPM Series Modular LED Light Selection table 1. Single light selection table WPM-® (D (3) (T) Voltage (2) Power 18: 18W(emergency) 2. Junction box selection table WPM-© (T) Function E: Emergency S1A: Junction box( with 230V socket) S1B: Junction box( with 400V socket) S: Rotary switch Example: WPM-A15C: WPM series LED lamp, AC100—264V, 15W, beam angle 120°*120°....
Open the catalog to page 3WPM Series Modular LED Light WPM-PJ1 Magnet WPM-PJ4 Resilient mounting support 5. WPM series spare parts list Note: Other assembly requirement (such as multiple combinations or more outlet holes) can be customized, for further information, please contact us
Open the catalog to page 4WPM Series Modular LED Light Model Note: Make sure that the power supply voltage is consistent with the rated voltage of the lamp. When wiring, check the cable color and label for correct access. L1 and N input for normal lighting L2 and N input for emergency lighting L3 for standby PE for grounding L1: ON for normal lighting, OFF of L1 and L2 for emergency lighting. Function of WPME emergency test switch: 1.Emergency indicator Charging indicator (green): flash once when battery is lower than 80%, flash twice when battery is higher than 80%, keep green when it's full. 2. Fault indicator...
Open the catalog to page 5WPM Series Modular LED Light •The emergency function can be turned off by inching switch in emergency mode. •When L1 has no power, emergency mode can be started by pressing switch for 5s. • If you need to continue the emergency mode after 90-minutes discharge , you can restart the emergency function by pressing the switch for 5s. Precautions •The product adopts PC material components (such as lampshade, shell), and can't be directly or indirectly touched with organic solvents such as industrial alcohol, banana oil, isopropyl alcohol, carbon tetrachloride, cyclohexanone, etc., otherwise it...
Open the catalog to page 6All Shanghai Nanhua Electronics Company catalogs and technical brochures
-
ZEN7e LED Light
4 Pages
-
LW34/LW34L LED Linear Light
4 Pages
-
LF22 High Bay Light
4 Pages
-
LF43 Series LED Flood Light
3 Pages
-
FAR Ultrasonic Wind Sensor
4 Pages
-
BC-8 Audible Visual Alarm
8 Pages
-
AL120 Audible Visual Alarm
9 Pages
-
TW101 Intercom System
2 Pages
-
ZD402Power Supply Cabinet
5 Pages
-
ABC-7A
1 Pages
-
ABC-7L
2 Pages
-
LS310
2 Pages
-
AL110U
2 Pages
-
AL80
2 Pages
-
AL07S Tower signal
3 Pages
-
ABC-401
1 Pages
-
LM100
4 Pages
-
LP1X Ex LED Area light
2 Pages
-
LP201A Helideck Status Light
2 Pages
-
LP4Circle-H Helideck Light
3 Pages
-
HD301A Platform edge light
1 Pages
-
SL301A LED light
1 Pages
-
LW24XX
2 Pages
-
LY455B Emergency LED Light
2 Pages
-
LY455LED Linear Light
1 Pages
-
LF21LED Flood Light
4 Pages
-
LF30Series
5 Pages
-
LF43 Series
4 Pages
-
LF23
3 Pages
-
LF22
4 Pages
-
LW15 LED Work Light
3 Pages
-
LF70H LED Flood Light
4 Pages
-
AL001
1 Pages
-
BC-3B
1 Pages
-
AL600U
2 Pages
-
BC-110
1 Pages
-
AL310
3 Pages
-
BC-2
2 Pages
-
AS210
3 Pages
-
AS201A
2 Pages
-
LH88
16 Pages
-
LT602U
2 Pages
-
LT601U
2 Pages
-
LT101
2 Pages
-
LQ006U
1 Pages
-
BC-60
1 Pages
-
DT00
6 Pages
-
Wind Speed Sensor FA01
5 Pages
-
ZD402
2 Pages
-
TW101
2 Pages
-
LT864
5 Pages
-
LM40
6 Pages
-
LM101+LM212
2 Pages
-
LM101
1 Pages
-
LM403
4 Pages
-
LS810D
2 Pages
-
LS730U
1 Pages
-
LS710
2 Pages
-
LS31X-E1-V10
2 Pages
-
Wind power generation
11 Pages
-
Catalogue - port application
32 Pages
-
Aviation obstruction light
40 Pages
-
LF70 HIGH MAST LED LIGHTING
8 Pages