LM40
6Pages

{{requestButtons}}

Catalog excerpts

LM40 - 1

Products description and applicaiton LM40 Series type A aviation obstruction lights with ICAO certificate. Type A aviation obstruction light play a warning role in tall buildings to reduce aviation hazards,daytime is white, at night is white or red (optional). Advanced LED, optical and system control technology to meet the advantages of the most demanding applications For towers, chimneys, tall buildings,large bridges, large port machinery, large construction machinery, wind turbines and other aircraft need to play a warning role in the occasion Applicable to obstacles with a height of 105 m to 150 m. Applicable to high salinity areas Features • Aluminum alloy die-cast shell, the surface electrostatic powder spray yellow, anti-vibration, corrosion resistance; • Anti-UV, shock-resistant PC housing; Flammability level: UL94V0; • Waterproof silicone seal structure; • Optical design based on Fresnel lens principle, the light source using LED technology, long life, low energy consumption, high efficiency; • Professional EMC design, anti-electromagnetic interference; • Wind resistance: >240km / h; • Luminous intensity with the ambient light automatically switch ( daytime: 20000±25% cd,night: 2000±25% cd); • Luminous intensity with the ambient light auto switch(Daytime20000±25% cd,night2000±25% cd); • Lamp with fault alarm detection and alarm output; • GPS synchronization function; • Day and night auto switch, can be controlled by local time or photocell. Lamp Specifications Electrical parameters Mechanical parameters Input Voltage Fault Alarm PowerConsumpti on SurgeLightning Protection Electrostatic Discharge Dry contact (NO or NC optional) Temperature Optical parameters International Standard Light source LED life Light color Intensity Horizontal degree Vertical degree Work styles Flashing rate Flashing duration On/Off level ICAO(Annex 14)medium intensity aviation obstruction light standard and FAA-L865, CAAC MH6012-2015 LED >100,000h White / White +Red Daytime20000±25% cd night2000±25% cd 360° >3° flashing Daytime: 20/30/40 FPM; Night: 20/30/40/60 FPM, Steady burning; Default20FPM Daytime: 150ms; Night: 750ms 50-200lux

Open the catalog to page 1
LM40 - 2

Fault alarm Consumption Dry contact (NO or NC optional, default NO) 1200w Mechanical parameters Storage temperature Operating Temperature Ambient Humidity IP Rate Weight

Open the catalog to page 2
LM40 - 3

LM40 Medium Intensity Aviation Obstruction LightWiring diagram 48V- 48V+ PE NC COM NO alarm Output picture 6 Lamp connection Wiring diagram picture 5 AC Powercabinet installationwiring diagram • Secure the light on a smooth surface which has enough strength, if there is no mounting surface, we can customize special mounting bracket as request. • When installation, please stay away the nearby light source, at the same time, ensure the photocell do not cover by the near object (suitable for light with photocell). •Make sure the power supply can match the rated power of light before...

Open the catalog to page 3
LM40 - 4

Dial value DIP Work status |Time control priority photocell priority Noted 4: The factory setting defaults to photocell controlled priority. BIT7 : DIP switch function setting below: Dial Number Dial the frequency non-effective Noted 5: The factory setting defaults to flash frequency setting valid. BIT8 : DIP switch function setting below: Dial Number Noted 6: If the lamp including red light, the factory setting defaults to red light priority. Noted 7:The DIP switch is 0 at the digital end, and 1 at the ON Time control priority application Introduction •Time-controlled factory default...

Open the catalog to page 4
LM40 - 5

LM40 Medium Intensity Aviation Obstruction LightFault alarm function •When the lamp is not receiving a power supply or a lamp fault:The relay has no action," common terminal" and "normal closeterminal' close, as below: •The lights are connected to the power supply and are working properly:Relay action, "common terminal" and "normal open terminal'close, as below: • If there is no power access, or failure are received "disconnect" signal, the alarm signal line connected to the "common" + "normally open" •If the "closed" signal is received when there is no power supply access or fault, the...

Open the catalog to page 5
LM40 - 6

LM40 Medium Intensity Aviation Obstruction LightOrder number Product No. 1000243-001 1000243-004 1000243-005 1000243-006 1000243-007 1000243-012 1000243-014 1000243-015 Input Voltage Color white(daytime) white(night) white(daytime)+red(night) +whitestandby (night) white(daytime) white(night) white(daytime) white(night) white(daytime)+red(night) +whitestandby (night) white(daytime)+red(night) +whitestandby (night) white(daytime) white(night) white(daytime)+red(night) +whitestandby (night) Work Styles Default 40FPM Fault Alarm YES Installation Method Small base (cable diameter cpI...

Open the catalog to page 6

All Shanghai Nanhua Electronics Company catalogs and technical brochures

  1. ABC-7A

    1 Pages

  2. ABC-7L

    2 Pages

  3. LS310

    2 Pages

  4. AL110U

    2 Pages

  5. AL80

    2 Pages

  6. ABC-401

    1 Pages

  7. LM100

    4 Pages

  8. LW24XX

    2 Pages

  9. LF30Series

    5 Pages

  10. LF43 Series

    4 Pages

  11. LF23

    3 Pages

  12. LF22

    4 Pages

  13. AL001

    1 Pages

  14. BC-3B

    1 Pages

  15. AL600U

    2 Pages

  16. BC-110

    1 Pages

  17. AL310

    3 Pages

  18. BC-2

    2 Pages

  19. AS210

    3 Pages

  20. AS201A

    2 Pages

  21. LH88

    16 Pages

  22. LT602U

    2 Pages

  23. LT601U

    2 Pages

  24. LT101

    2 Pages

  25. LQ006U

    1 Pages

  26. BC-60

    1 Pages

  27. DT00

    6 Pages

  28. ZD402

    2 Pages

  29. TW101

    2 Pages

  30. LT864

    5 Pages

  31. LM101+LM212

    2 Pages

  32. LM101

    1 Pages

  33. LM403

    4 Pages

  34. LS810D

    2 Pages

  35. LS730U

    1 Pages

  36. LS710

    2 Pages

  37. LS31X-E1-V10

    2 Pages