Catalog excerpts
Patent No. ZL 2011 2 0289179.9 AS210/AS211/AS212 YH10-2 Configuration speaker YH25-3 Configuration speaker YH50-3 Configuration speaker SE gooseneck microphone SS-A handheld microphone Shanghai Nanhua Electronics Co., Ltd Rd, Jiading district Shanghai 201802 AS210/AS211/AS212 Crane Loudspeaker & Controller Kit Applications Used in the cabs of engineering machinery (travelling cranes, crawler cranes, truck cranes and etc.) ,port machinery(gantry crane, overhead travelling cranes and etc.). Major functions and features • Speaking prior to alarm. • Volume adjustable. • Microphone & Loudspeaker available. • Various tones to choose from. • Visible and audible alarm synchronous (optional). • Power off memory, can hold the setting data. • Several kinds of combination mode for choose. • Nice appearance, convenient opeartion. Specifications Supply voltage Alarm tone A、B、E(customized available) Output Carrier power Aluminum alloy Ambient temperature Humidity • Mount the device onto mounting surface with 4 X M6 screws, the mounting surface should have enough strength to hold the device. • Make sure power supply is matched to the device’s rated voltage, and noted the Polarity, Wiring the device base on “wiring drawing” to connect external devices, and please take notice of negative and positive pole when connect the gooseneck microphone. • Power on, the red power indicator lighting, push the key of ′ON/OFF’ the indicator off, and the controller will be the standby mode, push again the controller will be the operation mode. • Audio-visual alarm separately,Push the “alarm indicator” switch, the yellow indicator lighting, and the alarm light terminal with AC220V output at the same time. Push again will be off. Choose Audio-visual alarm synchronously mode need push alarm-indicator and alarm-button. • Audio-visual alarm separately:only alarm system work when push the alarm-button. • Audio-visual alarm synchronously: When push the alarm button, alarm system operation, and at the same time, yellow indicator will lighting, the alarm terminal with current output, loudspeaker will with alarm, push the alarm button again, alarm system and indicator will stop at the same time to obtain the Visible and audible alarm synchronous function. • Tone select; push the tone button, the A、 E tone will be alarm cycles, please choose the tone B、 you want. • Volume adjust, through the ∧ and ∨ of Volume to turn up and turn down the volume, if under the alarm condition, push the ∧ and ∨ of Volume to turn up and turn down the alarm volume; Push the microphone switch can be speaking, and constant push can adjust the volume of speaker. • Gooseneck microphone connected in the back board terminal, please noticed the negative and positive pole, handheld speaker connected in the frond board MIC, push the speaker switch, or close the gooseneck microphone can be speaking amplifier, at this time can through the volume adjust button to turn up and turn down the volume.
Open the catalog to page 1mm) Loudspeaker mounting dimension (unit:mm) YH10-2 loudspeaker × Controller mounting dimension(unit: AS210/AS211/AS212 Crane Loudspeaker & Controller Kit Operation panel Wiring diagram: Shanghai Nanhua Electronics Co., Ltd Rd, Jiading district Shanghai 201802 E-mail: sales@nanhua.com All rights reserved by Nanhua, without the written authorization of the Nanhua, a
Open the catalog to page 2AS210/AS211/AS212 Crane Loudspeaker & Controller Kit Selection table mounting dimension Flat installation Flat installation Flat installation Notice • The controller of this product is the indoor type. • Wiring correct, please avoid overload and Short circuit. • Check the supply power whether can match the rated power. • Loudspeaker power should with the standard configuration. • Temperature increasing when using will happen. • Do not open controller box. Any questions please contact us. • Please use this device after reading instruction manual. • Any questions please contact us....
Open the catalog to page 3All Shanghai Nanhua Electronics Company catalogs and technical brochures
-
WPM Series Modular LED Light
6 Pages
-
ZEN7e LED Light
4 Pages
-
LW34/LW34L LED Linear Light
4 Pages
-
LF22 High Bay Light
4 Pages
-
LF43 Series LED Flood Light
3 Pages
-
FAR Ultrasonic Wind Sensor
4 Pages
-
BC-8 Audible Visual Alarm
8 Pages
-
AL120 Audible Visual Alarm
9 Pages
-
TW101 Intercom System
2 Pages
-
ZD402Power Supply Cabinet
5 Pages
-
ABC-7A
1 Pages
-
ABC-7L
2 Pages
-
LS310
2 Pages
-
AL110U
2 Pages
-
AL80
2 Pages
-
AL07S Tower signal
3 Pages
-
ABC-401
1 Pages
-
LM100
4 Pages
-
LP1X Ex LED Area light
2 Pages
-
LP201A Helideck Status Light
2 Pages
-
LP4Circle-H Helideck Light
3 Pages
-
HD301A Platform edge light
1 Pages
-
SL301A LED light
1 Pages
-
LW24XX
2 Pages
-
LY455B Emergency LED Light
2 Pages
-
LY455LED Linear Light
1 Pages
-
LF21LED Flood Light
4 Pages
-
LF30Series
5 Pages
-
LF43 Series
4 Pages
-
LF23
3 Pages
-
LF22
4 Pages
-
LW15 LED Work Light
3 Pages
-
LF70H LED Flood Light
4 Pages
-
AL001
1 Pages
-
BC-3B
1 Pages
-
AL600U
2 Pages
-
BC-110
1 Pages
-
AL310
3 Pages
-
BC-2
2 Pages
-
AS201A
2 Pages
-
LH88
16 Pages
-
LT602U
2 Pages
-
LT601U
2 Pages
-
LT101
2 Pages
-
LQ006U
1 Pages
-
BC-60
1 Pages
-
DT00
6 Pages
-
Wind Speed Sensor FA01
5 Pages
-
ZD402
2 Pages
-
TW101
2 Pages
-
LT864
5 Pages
-
LM40
6 Pages
-
LM101+LM212
2 Pages
-
LM101
1 Pages
-
LM403
4 Pages
-
LS810D
2 Pages
-
LS730U
1 Pages
-
LS710
2 Pages
-
LS31X-E1-V10
2 Pages
-
Wind power generation
11 Pages
-
Catalogue - port application
32 Pages
-
Aviation obstruction light
40 Pages
-
LF70 HIGH MAST LED LIGHTING
8 Pages