1. Catalogs
  2. Shanghai LEEG Instruments Co.,Ltd.
  3. SMP858-TST-S clamp on diaphragm pressure transducer

SMP858-TST-S clamp on diaphragm pressure transducer

SMP858-TST-S clamp on diaphragm pressure transducer
1 / 15 PagesView full catalog

SMP858-TST-S clamp on diaphragm pressure transducer

Product catalog summary
Product Introduction
The SMP858-TST-S is a hygienic pressure transmitter designed for the food and pharmaceutical industries. It supports CIP/SIP cleaning and sterilization, featuring a compact design with a welded process diaphragm made of stainless steel 316L, compliant with FDA hygiene standards. It offers various international standard process connections.
Main Parameters
  • Pressure Type: Gauge pressure
  • Measuring Range: 10kPa-3MPa
  • Output Signal: 4-20mA, 4-20mA+HART
  • Reference Accuracy: ±0.2% URL, ±0.5% URL
  • Measuring Medium: Compatible fluids with wetted parts
Technical Specifications
  • Measuring Range and Limit: Various ranges with specific lower and upper limits
  • Accuracy: ±0.2% URL
  • Stability: ±0.2% URL/year
  • Temperature Effects: Total impact ±0.2% URL/10k
  • Power Supply Effects: Zero and span change ≤ ±0.005% URL/V
  • Vibration Resistance: 10g RMS (25-2000HZ)
  • Impact Resistance: 500g/1ms
Environmental Conditions
  • Working Temperature: -40-85℃
  • Storage Temperature: -40-110℃
  • Media Temperature: -10-125℃
  • Humidity: 0-95%RH
  • Protection Class: IP67
Power Supply and Load Requirements
  • Standard Voltage: 10.5-55VDC
  • HART Protocol: 16.5-55VDC
  • Load Resistance: 0-2119 Ω
  • Power Consumption: ≤500mW@24VDC
EMC Environment
The device complies with various standards for radiated and conducted interference, electrostatic discharge, and other electromagnetic compatibility tests.
Menu Functions
  • Fix Output: Adjustable output values
  • Display Modes: Various display options for process variables and current
  • Alarm Signals: Configurable alarm settings
Product Selection and Configuration
Options include sensor seal, electrical connection, output signal, display, and process connection materials and types.
Product Drawings and Dimensions
Detailed dimensions and installation sketches for various configurations and process connections are provided.
Specifications
  • Fluid Filling: Hygienic fluid (Neobee M-20) with a process temperature range of -10 to 180℃; Silicon oil with a process temperature range of -45 to 205℃.
  • Diaphragm Material: SUS316L and Hastelloy C.
  • Process Connection: Various options including Tri-Clamp, DIN32676, ISO2852, DIN11851, SMS, IDF, and DRD with maximum measuring ranges from 1.6MPa to 4MPa.
Additional Options
  • Separator specifications and process connection accessories such as tri-clamps, sealing gaskets, and welding adapters.
  • Calibration report available upon request.
Approvals and Certifications
  • Flame Proof Certificate: ExdIICT6, NEPSI.
  • Intrinsic Safety Certificate: ExiaIICT4, NEPSI.
  • CE Certificate: Complies with EMC instruction 2014/30/EU, standard EN61326-1: 2013.
  • Factory Certificate: ISO9001-2008 certified by Intertek.
Factory Settings and Parameters
  • Analog output type: mA Liner.
  • Display mode: DISP PV.
  • Alarm signal: No.
  • Damping value: 0 (No specific settings).
  • 4mA Lower range value and 20mA Upper range value: According to the order.
  • Process unit: According to the order.
Contact Information
Shanghai LEEG Instruments Co., Ltd., No.100 Duhui Road, Minhang District, Shanghai, China. Tel: (86) 21-31261976, Email: [email protected], [email protected], Web: www.leegsensor.com
See more

Catalog excerpts

SMP858-TST-S clamp on diaphragm pressure transducer-1

SENSING TOMORROW SMP858-TST-S monosilicon gauge pressure transmitter Product introduction Hygienic pressure transmitter Hygienic pressure transmitter, designed for food and pharmaceutical industry, is suitable for CIP/SIP cleaning and sterilization. Smart compact design, the welded process diaphragm medium parts is made of high quality stainless steel 316L, roughness<0.4um, filling fluid with hygiene standard in line with FDA certification, variety of international standard process connections are available. Main parameters Measuring medium The fluids which compatible with wetted parts Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve

 Open the catalog to page 1
SMP858-TST-S clamp on diaphragm pressure transducer-2

SENSING TOMORROW SMP858-TST-S monosilicon gauge pressure transmitter Technical specifications Measuring range and limit Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve

 Open the catalog to page 2
SMP858-TST-S clamp on diaphragm pressure transducer-3

SENSING TOMORROW SMP858-TST-S monosilicon gauge pressure transmitter Technical Specifications Damping time Total damping time constant: equal to the sum of damping time of amplifer and sensor capsule Damping time of amplifer: 0-100S adjustable Diaphragm capsule (isolated diaphragm and silicon oil filling) damping time: <0.2S Startup after power off: <6S Normal services after data recovery: <31S Power supply Power supply and load requirements Net weight: about 1.6kg(without mounting brackets and process connection accessories) Environment condition *Please contact engineers for details Disclaimer:...

 Open the catalog to page 3
SMP858-TST-S clamp on diaphragm pressure transducer-4

SENSING TOMORROW SMP858-TST-S monosilicon gauge pressure transmitter Technical Specifications Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve

 Open the catalog to page 4
SMP858-TST-S clamp on diaphragm pressure transducer-5

SENSING TOMORROW SMP858-TST-S monosilicon gauge pressure transmitter Menu function Specific menu Transmission module type

 Open the catalog to page 5
SMP858-TST-S clamp on diaphragm pressure transducer-6

SENSING TOMORROW SMP858-TST-S monosilicon gauge pressure transmitter Product selection instruction Sensor select instruction Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve

 Open the catalog to page 6
SMP858-TST-S clamp on diaphragm pressure transducer-7

SENSING TOMORROW SMP858-TST-S monosilicon gauge pressure transmitter Product selection instruction Transmission module Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve

 Open the catalog to page 7
SMP858-TST-S clamp on diaphragm pressure transducer-8

SENSING TOMORROW SMP858-TST-S monosilicon gauge pressure transmitter Product drawing and dimension SMP858-TST-S standard drawing and dimension with display( C ) ( unit:mm) SMP858-TST-S standard drawing and dimension without display( A ) ( unit:mm) Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve

 Open the catalog to page 8
SMP858-TST-S clamp on diaphragm pressure transducer-9

SENSING TOMORROW SMP858-TST-S monosilicon gauge pressure transmitter Product drawing and dimension SMP858-TST-S drawing and dimension with display(C) with cooling element(unit:mm) SMP858-TST-S drawing and dimension without display(A) with cooling element(unit:mm) Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve 2017.01.V1.0

 Open the catalog to page 9
SMP858-TST-S clamp on diaphragm pressure transducer-10

SENSING TOMORROW SMP858-TST-S monosilicon gauge pressure transmitter Product drawing and dimension Installation Sketches Installation Sketches Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve

 Open the catalog to page 10
SMP858-TST-S clamp on diaphragm pressure transducer-11

SENSING TOMORROW SMP858-TST-S monosilicon gauge pressure transmitter Product drawing and dimension Process connection (K20) (unit: mm) Process connection (K18) (unit: mm) Installation sketches Installation sketches Standard Specification Size(G) Diaphragm size(ΦM) Standard Specification Size(G) Diaphragm size(ΦM) Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve 2017.01.V1.0

 Open the catalog to page 11
SMP858-TST-S clamp on diaphragm pressure transducer-12

SENSING TOMORROW SMP858-TST-S monosilicon gauge pressure transmitter Product drawing and dimension Sealing gasket (M1-M2) (unit: mm) Standard Tri-Clamp Tri-Clamp Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve

 Open the catalog to page 12
SMP858-TST-S clamp on diaphragm pressure transducer-13

SENSING TOMORROW SMP858-TST-S monosilicon gauge pressure transmitter Ordering information chapter Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve

 Open the catalog to page 13
SMP858-TST-S clamp on diaphragm pressure transducer-14

SENSING TOMORROW SMP858-TST-S monosilicon gauge pressure transmitter Ordering information chapter Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve

 Open the catalog to page 14
SMP858-TST-S clamp on diaphragm pressure transducer-15

SENSING TOMORROW SMP858-TST-S monosilicon gauge pressure transmitterFactory settings and parameters Item Factory certificate SENSING TOMORROW LEEC Shanghai LEEG Instruments Co.,Ltd ADD: No.100 Duhui Road, Minhang District, Shanghai China Postcode:201109 Tel: (86) 21-31261976 Fax: (86)21-31261975 E-mail:[email protected] [email protected] Web: www.leegsensor.com Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve

 Open the catalog to page 15

All Shanghai LEEG Instruments Co.,Ltd. catalogs and technical brochures

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.