SMP858-TSF-S Pressure transmitter for hygienic area
15Pages

{{requestButtons}}

Catalog excerpts

SMP858-TSF-S Pressure transmitter for hygienic area - 1

SMP858-TSF Monosilicon gauge pressure transmitter SENSING TOMORROW Product introduction Sanitary pressure transmitter Sanitary pressure transmitter, designed for food and pharmaceutical industry, is suitable for CIP/SIP cleaning and sterilization.Smart compact design, the welded process diaphragm medium parts is made of high quality stainless steel 316L, roughness≤0.4um, filling fluid with hygiene standard in line with FDA certification, variety of international standard process connections are available.  vertical installation Main parameters Pressure types Gauge pressure Pressure, level Measuring range 10kPa-3MPa, please refer to the ordering information chapter Output signal Reference accuracy Measuring medium viscous, paste-like, adhesive, crystallising, particulatescontaining and contaminated media Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve 2016.11.V1.0

Open the catalog to page 1
SMP858-TSF-S Pressure transmitter for hygienic area - 2

SMP858-TSF Monosilicon gauge pressure transmitter SENSING TOMORROW Technical specifications Smallest calibratable span Lower range limit (LRL) Upper range limit (URL) Overpressure limit * Nominal value The unit of the measuring range above can be converted into kg/cm²、 MPa and kPa. Provide other measuring range according to requirements. Adjust requirements: lower range value (LRV) and upper range value (URV) can be adjusted within the scope of the upper and lower range limit, minimum measuring range≤| URV - LRV |≤maximum measuring range.   * Limit value of overpressure: depends on the...

Open the catalog to page 2
SMP858-TSF-S Pressure transmitter for hygienic area - 3

SMP858-TSF Monosilicon gauge pressure transmitter SENSING TOMORROW Technical specifications Damping time Power supply Total damping time constant: equal to the sum of damping time of amplifer and sensor capsule Operating conditions HART protocol Load resistance 0-2119Ω for operation, 250-600Ω for HART protocol Damping time of amplifer : 0-100S adjustable Damping time of sensor capsule (isolation sensor diaphragm and silicon filling oil)≤0.2S Startup after power off: ≤6S Normal services after data recovery:≤31S Transmission distance <1000 meters Power consumption Weight Power supply and load...

Open the catalog to page 3
SMP858-TSF-S Pressure transmitter for hygienic area - 4

SENSING TOMORROW SMP858-TSF Monosilicon gauge pressure transmitter Technical specifications Basic standards Test conditions Performance level Radiated interference Conducted interference (DC power port) Electrostatic discharge immunity test (ESD) GB/T 17626.2/IEC61000-4-2 4kV(Contact ),8kV(Air) Immunity to radio frequency EM-fields Power frequency magnetic field Immunity test Electrical fast transient / Burst Immunity Test Surge immunity requirements Immunity to conducted disturbances induced by radio frequency fields (Note 1)Performance level A: The preformance within the limits of normal...

Open the catalog to page 4
SMP858-TSF-S Pressure transmitter for hygienic area - 5

SMP858-TSF Monosilicon gauge pressure transmitter SENSING TOMORROW Menu function Transmission module type Output signal Local control 4-20mA+HART LCD/3 buttons on body LCD/3 buttons on body Remote control Upper range value Lower range value Damping time LCD display unit Units Display mode Process variable shows on main screen, percentage and progress bar shows on secondary screen Analog output type Current shows on main screen, percentage and progress bar shows on secondary screen Percentage shows on main screen, percentage and progress bar shows on secondary screen Output type Square root...

Open the catalog to page 5
SMP858-TSF-S Pressure transmitter for hygienic area - 6

SMP858-TSF Monosilicon gauge pressure transmitter SENSING TOMORROW Product selection instruction Sensor select instruction Electrical connection Code Item Nominal value Range -40kPa-40kPa, smallest calibratable span 10kPa Range -100kPa-250kPa, smallest calibratable span 25kPa Range -100kPa-1MPa, smallest calibratable span 100kPa Range -100kPa-3MPa, smallest calibratable span 300kPa Electrical Stainless steel termimal, aviation plug connection M12*1 (4 pin) (H2), IP67,vertical mounting Stainless steel termimal, aviation plug M12*1 (4 pin) (H2), IP67,horizontal mounting Adjust requirements:...

Open the catalog to page 6
SMP858-TSF-S Pressure transmitter for hygienic area - 7

SMP858-TSF Monosilicon gauge pressure transmitter SENSING TOMORROW Product selection instruction Electrical connetion accessories Aviation plug elbow(J1) Aviation plug straighter(J1) label 3 2 Brown Black Blue White Brown Black Blue White Transmission module Process connection select instruction Output signal 4-20mA two wire, power supply: 10.555VDC Process connector material Connection type Standard connection, medium temperature: -25-85℃ 4-20mA+HART two wire, power supply: 16.5-55VDC Display Without display Cooling element connector, medium temperature: -40-150℃ Display module(C)...

Open the catalog to page 7
SMP858-TSF-S Pressure transmitter for hygienic area - 8

SMP858-TSF Monosilicon gauge pressure transmitter Product drawing and dimension Standard drawing and dimension with d is play (C)/without display (A) vertical installation^ 1 )(unit:mm) Standard drawing and dimension with display©/without display (A )horizontal installation(F2)(unit:mm) Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve

Open the catalog to page 8
SMP858-TSF-S Pressure transmitter for hygienic area - 9

SMP858-TSF Monosilicon gauge pressure transmitter SENSING TOMORROW Product drawing and dimension High-temperature drawing and dimension with display(C)/ without display (A) vertical installation(F1)(unit:mm) High-temperature drawing and dimension with display(C)/ without display (A ) horizontal installation(F2)(unit:mm) Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve 2016.11.V1.0

Open the catalog to page 9
SMP858-TSF-S Pressure transmitter for hygienic area - 10

SMP858-TSF Monosilicon gauge pressure transmitter SENSING TOMORROW Product drawing and dimension Installation Sketches Installation Sketches Dimension Dimension Specification Size(ΦD) Diaphragm size (ΦM) Diaphragm size(ΦM) Specification Size(G) Process connection (K12-K13)(unit: mm) Installation Sketches Installation Sketches Dimension Dimension Specification Size(G) Diaphragm size(ΦM) Standard Specification Size(G) Diaphragm size(ΦM) Disclaimer: all the data used in the product description is not legally binding. Relevant technical details may be changed due to further improve 2016.11.V1.0

Open the catalog to page 10