SMP858-TSF High overload pressure transmitter for pharmacy
12Pages

{{requestButtons}}

Catalog excerpts

SMP858-TSF High overload pressure transmitter for pharmacy - 1

SMP858 - TSF Sanitary Pressure Transmitter Product information Brief introduction SMP858 sanitary type pressure transmitter, designed for food and pharmaceutical industry, is suitable for CIP/SIP clean ing and steri lizatio n.S mart com pact de si gn, the welded process diaphragm medium parts is made of high quality stainless steel 316L.roughness≤0.4um, filling fluid with hygiene standardsvariety of international standard process connections are available. Pressure Type Gage pressure and Absolute Pressure Gage pressure range Absolute pressure range 0 - 1 MPa , minimum range30kPa Output signal Measuring Medium Gas, steam, liquid Special Medium Any medium which is compatible of contact part Common function Gage pressure, absolute pressure and level Food and Pharmaceutical Pharmacy, food, beverage, juice, industry milk, beer.

Open the catalog to page 1
SMP858-TSF High overload pressure transmitter for pharmacy - 2

SMP858 - TSF Sanitary Pressure Transmitter Performance Parameters Performance reference calibration conditions 882-2004, standard parameters: 4-20mA two wire + HART output signal, standard benchmark zero calibration range, silicone oil, 316L stainless steel diaphragm, etc Nominal Range 6kPa Response time 150mS Reference Accuracy Linearity Standard output Linearity, sluggish and hysteresis start from zero ±0.1%Range Adjustment Span ratio (TD) is equal to the nominal Range scale range, TD>4 Installation effect ±[0.05+0.0125(URL/Range)]%Range Square root output 1.5 times better than the...

Open the catalog to page 2
SMP858-TSF High overload pressure transmitter for pharmacy - 3

SMP858 - TSF Sanitary Pressure Transmitter Menu function Transm ission module type Output signal Local control Remote control Note: All parameters can write by 3 buttons on body or LCD display unit,or by computers with HART software and HART communication. Someparameters can not be written without LCD display unit and HART protocol output. Nominal range Minimum measuring Lower range value range value SLH / SLL range Upper range value Note,The measuring range between upper range value and lower range value should be bigger than Minimum measuring range. Parameter name Setting range LCD...

Open the catalog to page 3
SMP858-TSF High overload pressure transmitter for pharmacy - 4

SMP858 - TSF Sanitary Pressure Transmitter Environment condition Pressure Limit Nominal Range Overload Operational condition Media temperature Sanitary Filling Fluid, -10~150℃ with cooling element Sanitary Filling Fluid, -10~150℃ without cooling element, 125℃ for 30 minutes Working humidity IP67, stainless steel housing body with M12x1(4 pin) Hadazous Place Proction class 1.5 times overload or depends on process fitting stress levels Reference dangerous situations license Power supply Emission requirements meet EN61 000-6-3 . Protection requirements and testing meet EN61 000-6-2 30V/m(IEC...

Open the catalog to page 4
SMP858-TSF High overload pressure transmitter for pharmacy - 5

SMP858 - TSF Sanitary Pressure Transmitter Product Selection Sensor Select Instruction Electrical Connection Sensor Property Electrical Connection Selection Code Item Gage Pressure Electrical Stainless Steel Terminal box, M12x1(4 Connection pin), IP67 Sensor Selection Absolute Pressure High Vacuum occasions(absolute pressure <20kPa) Sealing Style Stainless Steel Welded Seal Electrical C onnection Assem bly Range Code Code Nominal Value Details S602 6kPa Nominal measuring range: 6kPa, Min Range: 5kPa Nominal measuring range: 35kPa, Min Range: 10kPa Nominal measuring range: 100kPa, Min Range:...

Open the catalog to page 5
SMP858-TSF High overload pressure transmitter for pharmacy - 6

SMP858 - TSF Sanitary Pressure Transmitter Product Selection Process Connection Selection Transm itting Module (C1) Process Connection & Material Output 4-20mA two wires, suitable for supply voltage signal type 12-30vdc 4-20Ma+HART two wires, suitable for supply voltage 12-30vdc Mechanical connection Display & Operate Module With LCD display module Without display Display type Plug - in cartridge flush sanitary clamp Connection type without cooling element with cooling element Isolated filling fluid Sanitary filling fluid, Neobee M-20, suitable for temperature range from -10 to 180℃...

Open the catalog to page 6
SMP858-TSF High overload pressure transmitter for pharmacy - 7

SMP858 - TSF Sanitary Pressure Transmitter

Open the catalog to page 7
SMP858-TSF High overload pressure transmitter for pharmacy - 8

SMP858 - TSF Sanitary Pressure Transmitter Process Connection Dimensional Drawing Installation Sketches Installation Sketches Installation Sketches Installation Sketches

Open the catalog to page 8
SMP858-TSF High overload pressure transmitter for pharmacy - 9

SMP858-TSF Sanitary Pressure Transmitter Process Connection Dimension Drawing Thread Taper Sealing Installation Sketches Installation Sketches

Open the catalog to page 9
SMP858-TSF High overload pressure transmitter for pharmacy - 10

SMP858 - TSF Sanitary Pressure Transmitter Process Connection Dimensional Drawing Plug-in Cartridge Flush Sanitary Clamp Installation Sketches

Open the catalog to page 10
SMP858-TSF High overload pressure transmitter for pharmacy - 11

SMP858-TSF Sanitary Pressure Transmitter

Open the catalog to page 11
SMP858-TSF High overload pressure transmitter for pharmacy - 12

SMP858 - TSF Sanitary Pressure Transmitter Plug-in Cartridge Flush Sanitary Clamp Factoty certificate Intrinsic Certificate Certification Organization Quality Management System ISO9001-2008 Pressure Transmitter SMP Series Design and production of Pressure transmitter Ex-Proof Mark Registration number Ambient Temperature Medium Max Temperature +80℃ Registration Code Max Input mA: 93mA Max Input Wattage: 0.66W Scope of Certification PREUSSURE TRANSMITTER Standard Max Internal Equivalent Parameters Ci(nF):0.035 Max Internal Equivalent Parameters Li(mH): ≈0 Registration Code Intrinsic Parameter...

Open the catalog to page 12

All Shanghai LEEG Instruments Co. catalogs and technical brochures