Catalog excerpts

THREE(3)ROTARY BLOWER SHANDONG PROVINCE HUIFENG MACHINERY GROUP GENERAL COMPANY SHANDONG ZHANGQIU BLOWER CO.,LTD
Open the catalog to page 1
»APPLICATION EXAMPLES t mn) Waste water Aeration in Condominiums ■iritTKfaS/^K&hl! ( mH) Waste Water Aeration for Shops and Livestock Industries Fish Care mm&tp Combustion a Fireplace Stirring in Plated Vessel Transport of Particles Vacuum Pack for Foods
Open the catalog to page 3
ROOTS TYPE ROTARY BLOWERS FEATURES RmmmAim. i #ma. m&iATtfiiimMmmm. *R#iwat**n. **ib3*£***r#i»#£ WISHTTfSjfcffl . 0rfel£»*-&«/J\ . Jl¥»WflWU* ja. # . HUb . RIEffl aTSiffli. flrw. si, «fw. itm . r»a«a jisi aftft«gfliwiHtta. s®«* ujmsnjta. mm®. . tsttasnaAm**# iir^fpin. ±;**a{**j»*a, mu «8#«s3cat. «£/*&*. sm/i The helical construction uses the stator helical method that the screen lines of casing at the suction and discharge sides are cut to a helical shape,and tire triangle suction and discharge port formed by a straight line of the rotor top is to be opened and closed...
Open the catalog to page 4
»ssr m »HOW TO USE PERFORMANCE TABLES qg. $tii. IRE -h. ▲ mm 1101.3kPa!) ffljxlg. —»W-Nm*/min*S. $3& WRI, Qs=Qn x 1.0732 Qs: (m-’/min) (m'/min) PrfflMff* (kgf/cm') tsiSMSSE CC) td:WSS CC) A . iittfffEtig The performance fables give the model numbcr.bore.r.p.m.. discharge prcssure.air capacity and rajuired power of the blower. A The air capacity in the tables is indicated in the standard suction stale. The standard suction stale herein mentioned is defined as the condition at 20 C temperature. 1.0332kgf/cm’ (IOI.3kPa)absolule pressure and 65% relative humidity. A The reference air...
Open the catalog to page 5
»SSR ft fig $ »TYPE SSR PERFORMANCE TABLE Qs; iSJ*ltt;SRM(m3/rnin) Lg. Jj(kW) Suction-phase Air Volume(m3/min) Required electric power(kW) | |n 7SkW 1 | l.lkW | | 1.5kW | 12.2kW | 13kW I 14kW I 15.5kW I I 7.5kW | | IlkW
Open the catalog to page 6
»TYPE SSR PERFORMANCE TABLE
Open the catalog to page 7
Vacuum Volume al each Discharge pressure(ms/min) a' Required electric power(kW)
Open the catalog to page 8
»SSR-V W£'\± »TYPE SSR-V VACUUM PERFORMANCE TABLE
Open the catalog to page 9
»TYPE SSR DIRECT COUPLING PERFORMANCE TABLE ■VIA Type
Open the catalog to page 10
» TYPE SSR OUTLINE DIMENSIONS ■T'-ft/mm Unit/mm a) Note:The weights given do not include the motor.
Open the catalog to page 11
»TYPE SSR DIRECT COUPLING OUTLINE DIMENSIONS
Open the catalog to page 12
» TYPE SSR NOISE LEVEL NOISE LEVEL dB(A) Machine Side 1.0m Note:There values are based on the measurements taken in our shop
Open the catalog to page 13
Suction—phase Air Volume(m3/min) TYPE SSR-HB PERFORMANCE TABLE La; (kW) Required electric power(kW) 10.75kW I | l.lkW | | 1.5kW | 12.2kW | |3kW | 14kW | 15.5kW | | 7.5kW | | IlkW
Open the catalog to page 14
] 5.5kW | | 7.5kW | | IlkW I I 15kW Os: iSRlWSRls (ms min) Suction-phase Air Volume(mJ,min) La; BtSSSST} (kW) Required electric power(kW)
Open the catalog to page 15
SSR-VHBi? i TYPE SSR-VHB VACUUM PERFORMANCE TABLE Qs: SKSSTWia* (m’/min) (kW) Vacuum Volume at each Discharge pressure(m3/min) : Required electric power(kW)
Open the catalog to page 16
TYPE SSR-VHB VACUUM PERFORMANCE TABLE DRAWING OF VACUUM PIPING ftrabKBMsBaa ZMvXtntxKUa
Open the catalog to page 17
TYPE SSR-HB DIRECT COUPLING PERFORMANCE TABLE
Open the catalog to page 18
Note:The weights given do not include the motor.
Open the catalog to page 19
SSR-HB^K§y TYPE SSR-HB NOISE LEVEL • *HldB(A) t/lfJI-Om NOISE LEVEL dB(A) ' ' Side 1.0m Note:There values are based on the measurements taken in our shop
Open the catalog to page 21
SSR-HBujEsUi REFERENCE DRAWING OF PIPING FOR TYPE SSR-HB PULLEY TRANSMISSION DRAWING OF PIPING Vibration-isolator Base sarniAis (rkm) Vertical Dscharge SHencerfRKM) Discharge Sfencer (TYPE KM) fM(GVS) Gale Va vs (TYPEGV) Rubber Vibrador Isolator Note: Make sure that the piping of Check valve type DCV is horizontal
Open the catalog to page 22
SSR-HB-UfuJ3i fi t -rt ■ Qs iSRttiSiPIS (mVmin) Suclion-phase Air Volume(m3/min) SSR-HB-U PERFORMANCE TABLE ■ La, BfSSfiifr IkW) Required electric power(kW)
Open the catalog to page 23
■ Os, SRttrSHft (mJ/min) Suction-phase Air Volume|m’/min) ■ La, PUrfiSlifl (kW) Required electric power(kW)
Open the catalog to page 24
>4: Note^ The weights given include the motor
Open the catalog to page 25
Suction-phase Air Volume!|f/min) La. mdlft (kW) ' ' Inquired electric power(kW)
Open the catalog to page 26
Qs. itHtt-SHS (d/inin) ’ Suction-phase Air Volume (f/inin) La. Rritdjtj (kW) " ' Required electric power(kW)
Open the catalog to page 27
TYPE SSR-T OUTLINE DIMENSIONS ssR-m TYPE SSR-20T TYPE SSR-25T TYPE SSR-32T ★#>IWiip0p • «A5BjS# • • mmto • mm& Note: The mass given do not include the motor. m I'tiWilitiL Note; The mass given do not include the motor.
Open the catalog to page 28
mm (W)Rubber Vibration lsolator(TYPE A a =s Type mm (m)Rubber Vibration lsolator(TYPE B) V> A Type KKs&S (SSR-HB) Vibration-Isolating Base(SSR-HB) SI'S Type Application Type Check Valve(CV)
Open the catalog to page 29
SHANDONG ZHANGQIU BLOWER CO.,LTD 邮局信箱 4588 美国.伊利诺伊州.惠顿市 邮编:60189 电话:630-221-8282 传真:630-221-1002 电邮:info@eurusblower.com 网址:www.eurusblower.com 地址:山东省章丘市明水经济开发区世纪大道东首 Add:Mingshui Economic Development Zone,Zhangqiu City, Shandong Province,China 电话(TEL):0531-83250025 83250036(销售公司 Sales Company) +86+531+83250080(外贸公司 Foreign Trade Company) 传真(FAX):0531-83225838(销售公司 Sales Company) +86+531+83250082(外贸公司 Foreign Trade Company) E-ma
Open the catalog to page 30All Shandong Zhangqiu Blower Co. catalogs and technical brochures
-