Catalog excerpts
THREE(3)ROTARY BLOWER SHANDONG PROVINCE HUIFENG MACHINERY GROUP GENERAL COMPANY SHANDONG ZHANGQIU BLOWER CO.,LTD
Open the catalog to page 1»APPLICATION EXAMPLES t mn) Waste water Aeration in Condominiums ■iritTKfaS/^K&hl! ( mH) Waste Water Aeration for Shops and Livestock Industries Fish Care mm&tp Combustion a Fireplace Stirring in Plated Vessel Transport of Particles Vacuum Pack for Foods
Open the catalog to page 3ROOTS TYPE ROTARY BLOWERS FEATURES RmmmAim. i #ma. m&iATtfiiimMmmm. *R#iwat**n. **ib3*£***r#i»#£ WISHTTfSjfcffl . 0rfel£»*-&«/J\ . Jl¥»WflWU* ja. # . HUb . RIEffl aTSiffli. flrw. si, «fw. itm . r»a«a jisi aftft«gfliwiHtta. s®«* ujmsnjta. mm®. . tsttasnaAm**# iir^fpin. ±;**a{**j»*a, mu «8#«s3cat. «£/*&*. sm/i The helical construction uses the stator helical method that the screen lines of casing at the suction and discharge sides are cut to a helical shape,and tire triangle suction and discharge port formed by a straight line of the rotor top is to be opened and closed...
Open the catalog to page 4»ssr m »HOW TO USE PERFORMANCE TABLES qg. $tii. IRE -h. ▲ mm 1101.3kPa!) ffljxlg. —»W-Nm*/min*S. $3& WRI, Qs=Qn x 1.0732 Qs: (m-’/min) (m'/min) PrfflMff* (kgf/cm') tsiSMSSE CC) td:WSS CC) A . iittfffEtig The performance fables give the model numbcr.bore.r.p.m.. discharge prcssure.air capacity and rajuired power of the blower. A The air capacity in the tables is indicated in the standard suction stale. The standard suction stale herein mentioned is defined as the condition at 20 C temperature. 1.0332kgf/cm’ (IOI.3kPa)absolule pressure and 65% relative humidity. A The reference air...
Open the catalog to page 5»SSR ft fig $ »TYPE SSR PERFORMANCE TABLE Qs; iSJ*ltt;SRM(m3/rnin) Lg. Jj(kW) Suction-phase Air Volume(m3/min) Required electric power(kW) | |n 7SkW 1 | l.lkW | | 1.5kW | 12.2kW | 13kW I 14kW I 15.5kW I I 7.5kW | | IlkW
Open the catalog to page 6»TYPE SSR PERFORMANCE TABLE
Open the catalog to page 7Vacuum Volume al each Discharge pressure(ms/min) a' Required electric power(kW)
Open the catalog to page 8»SSR-V W£'\± »TYPE SSR-V VACUUM PERFORMANCE TABLE
Open the catalog to page 9»TYPE SSR DIRECT COUPLING PERFORMANCE TABLE ■VIA Type
Open the catalog to page 10» TYPE SSR OUTLINE DIMENSIONS ■T'-ft/mm Unit/mm a) Note:The weights given do not include the motor.
Open the catalog to page 11»TYPE SSR DIRECT COUPLING OUTLINE DIMENSIONS
Open the catalog to page 12» TYPE SSR NOISE LEVEL NOISE LEVEL dB(A) Machine Side 1.0m Note:There values are based on the measurements taken in our shop
Open the catalog to page 13Suction—phase Air Volume(m3/min) TYPE SSR-HB PERFORMANCE TABLE La; (kW) Required electric power(kW) 10.75kW I | l.lkW | | 1.5kW | 12.2kW | |3kW | 14kW | 15.5kW | | 7.5kW | | IlkW
Open the catalog to page 14] 5.5kW | | 7.5kW | | IlkW I I 15kW Os: iSRlWSRls (ms min) Suction-phase Air Volume(mJ,min) La; BtSSSST} (kW) Required electric power(kW)
Open the catalog to page 15SSR-VHBi? i TYPE SSR-VHB VACUUM PERFORMANCE TABLE Qs: SKSSTWia* (m’/min) (kW) Vacuum Volume at each Discharge pressure(m3/min) : Required electric power(kW)
Open the catalog to page 16TYPE SSR-VHB VACUUM PERFORMANCE TABLE DRAWING OF VACUUM PIPING ftrabKBMsBaa ZMvXtntxKUa
Open the catalog to page 17TYPE SSR-HB DIRECT COUPLING PERFORMANCE TABLE
Open the catalog to page 18Note:The weights given do not include the motor.
Open the catalog to page 19SSR-HB^K§y TYPE SSR-HB NOISE LEVEL • *HldB(A) t/lfJI-Om NOISE LEVEL dB(A) ' ' Side 1.0m Note:There values are based on the measurements taken in our shop
Open the catalog to page 21SSR-HBujEsUi REFERENCE DRAWING OF PIPING FOR TYPE SSR-HB PULLEY TRANSMISSION DRAWING OF PIPING Vibration-isolator Base sarniAis (rkm) Vertical Dscharge SHencerfRKM) Discharge Sfencer (TYPE KM) fM(GVS) Gale Va vs (TYPEGV) Rubber Vibrador Isolator Note: Make sure that the piping of Check valve type DCV is horizontal
Open the catalog to page 22SSR-HB-UfuJ3i fi t -rt ■ Qs iSRttiSiPIS (mVmin) Suclion-phase Air Volume(m3/min) SSR-HB-U PERFORMANCE TABLE ■ La, BfSSfiifr IkW) Required electric power(kW)
Open the catalog to page 23■ Os, SRttrSHft (mJ/min) Suction-phase Air Volume|m’/min) ■ La, PUrfiSlifl (kW) Required electric power(kW)
Open the catalog to page 24>4: Note^ The weights given include the motor
Open the catalog to page 25Suction-phase Air Volume!|f/min) La. mdlft (kW) ' ' Inquired electric power(kW)
Open the catalog to page 26Qs. itHtt-SHS (d/inin) ’ Suction-phase Air Volume (f/inin) La. Rritdjtj (kW) " ' Required electric power(kW)
Open the catalog to page 27TYPE SSR-T OUTLINE DIMENSIONS ssR-m TYPE SSR-20T TYPE SSR-25T TYPE SSR-32T ★#>IWiip0p • «A5BjS# • • mmto • mm& Note: The mass given do not include the motor. m I'tiWilitiL Note; The mass given do not include the motor.
Open the catalog to page 28mm (W)Rubber Vibration lsolator(TYPE A a =s Type mm (m)Rubber Vibration lsolator(TYPE B) V> A Type KKs&S (SSR-HB) Vibration-Isolating Base(SSR-HB) SI'S Type Application Type Check Valve(CV)
Open the catalog to page 29SHANDONG ZHANGQIU BLOWER CO.,LTD 邮局信箱 4588 美国.伊利诺伊州.惠顿市 邮编:60189 电话:630-221-8282 传真:630-221-1002 电邮:info@eurusblower.com 网址:www.eurusblower.com 地址:山东省章丘市明水经济开发区世纪大道东首 Add:Mingshui Economic Development Zone,Zhangqiu City, Shandong Province,China 电话(TEL):0531-83250025 83250036(销售公司 Sales Company) +86+531+83250080(外贸公司 Foreign Trade Company) 传真(FAX):0531-83225838(销售公司 Sales Company) +86+531+83250082(外贸公司 Foreign Trade Company) E-ma
Open the catalog to page 30All Shandong Zhangqiu Blower Co. catalogs and technical brochures
-
SSR-K 2024
3 Pages
-
Pneumatic Conveying Equipment
16 Pages
-
C Multi-stage centrifugal blower
15 Pages
-
LRA
20 Pages
-
Eurus ZZ
5 Pages
-
Environment Cerficate
1 Pages
Archived catalogs
-
ZW Roots Blower-2016
11 Pages
-
ZG Roots Blower
13 Pages