Catalog excerpts
SHANDONG FRIEND CONTROL SYSTEM CO.,LTD SHANDONG FRIEND CONTROL SYSTEM CO.,LTD FD3051S Monocrystalline Silicon Differential Pressure Transmitter ◆ Product Selection Guide FD3051S Monocrystalline Silicon Differential Pressure Transmitter ◆ Product Selection Guide FD3051S LT-Pressure level Transmitter FD3051S LT-Pressure level Transmitter FD3051S LT Differential Pressure Level Transmitter Technical Parameter Product Introduction Technical Parameter One-sided overload up to the rated pressure. Possibly occurring zero offsets can becorrected. Material Aluminum with epoxy resin coat Housing Gasket: Perbunan(NBR) Explosion Protected Type NEPSI / ATEX: Ex d Ⅱ C T6 Name plate 304 stainless steel Electrical Connection Cable entry M20x1.5.The screw terminals are suitable for Supply & Load Requirements Process Connection Pressure:ANSI standard or DIN standards See Table Flange with fixing thread ,See Table Working: 0~1040Ω Digital communication: 230~600Ω Response Time damping time constant is adjustable from 0.1 to 60 sec Installation conditions axes are vertical. Deviations from this can cause a shift in the zero, which can be corrected. The electronic Preferably in such a position that the process flange housing can be rotated through 360° and can be fixed Ambient temperature Min:depends on the fill fluid Test items Basic standards Test conditions Performance Level Radiated interference (Housing) Conducted interference (DC power port) The transmitter can be directly flanged in any position. The minimum measuring range Electrostatic Discharge (ESD) Immunity RF electromagnetic field immunity Frequency magnetic field immunity Electrical Fast Transient Burst Immunity Surge Immunity 1kV (line to line) 2kV (line to ground) (1.2us/50us) Conducted interference immunity induced by RF field The minimum measuring range of the differential pressure Level transmitter should be the larger value of span must not be lower than the minimum range. Measuring range Lower range value: -100% to +100% of the URL(continuously adjustable) Upper range value: Up to 100% of the URL(continuously adjustable) Output signal Two wire 4~20mADC output with digital communications, linear or square root programmable. HART FSK protocol superimposed on the 4~20 mADC signal. Output range: 3.9 mA to 20.5 mA. Failure Alarm (the mode can be selected) Low Mode (min): 3.7 mA, High Mode (max): 21 mA No Mode (hold): Keep the effective value before the fault. Protection Level by software and added to response time. Nominal diameter the minimum range of table 1 and table 2.The adjusted The amplifier damping constant is 0.1 sec; The sensor on the range and range compression ratio. Amplifier The flange’s working pressure Fill fluid and flange’s damping constant is 0.2~3 sec, it depends Table 2:Flange and minimum measuring range Flat sealing One-sided overload Technical Parameter Table 1:Span code, measuring range and SWP Bulge sealing Isolating SS316L/ Hastelloy C/Tantalum Diaphragm FEP or PFA plated on 316L The differential pressure level transmitter FD3051S LT is suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure.It outputs a 4~20mADC signal corresponding to the measured differential pressure. Its highly accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via HART communications. Other key features include quick response, remote set-up using communications, self-diagnostics and optional status output for pressure high/low alarm. The range Limits is 0— 1kPa ~ 2MPa, The flange’s working pressure are 1.6/4MPa, 6.4MPa,10MPa,150psi,300psi or 600psi. Technical Parameter Flange working pressure Storage temperature/transport temperature Min:depends on the fill fluid Max:85℃ Humidity:0 ~ 100% Shock resistant: Acceleration:50g,Duration:11ms Vibration resistance: 500Hz on 2g Electromagnetic Compatibility (EMC) Look the EMC Performance Table 3 Note:(1) Performance level A description: The technical specifications within the limits of normal performance. (2) Performance level B description: Temporary reduction or loss of functionality or performance, it can restore itself. The actual operating conditions, storage, and data will not be changed. Pressure limits: From 3.5kPa abs. to working pressure. Proof pressure u
Open the catalog to page 1山东福瑞德测控系统有限公司 SHANDONG FRIEND CONTROL SYSTEM CO.,LTD FD3051S Monocrystalline Silicon Differential Pressure Transmitter FD3051S Monocrystalline Silicon Differential Pressure Transmitter ◆ Product Selection Guide ◆ Product Selection Guide FD3051S LT-Pressure level Transmitter FD3051S LT-Pressure level Transmitter Product Dimensions Terminal side Low-Pressure side Ground terminal Locking case screw Working pressure Electrical Connection Calibration instrument connection hook Electrical terminal Test Power + Power– M20×1.5 D-shaped connector (Code C2) Low-Pressure side accessory Level Flange...
Open the catalog to page 2All Shandong Friend Control System Co. catalogs and technical brochures
-
FDWSS
1 Pages
-
FDWR
1 Pages
-
FDWZ
1 Pages
-
FDWB
1 Pages
-
FD3051LT
1 Pages
-
FD3051LD
1 Pages
-
FD86
1 Pages
-
FD86E/F
1 Pages
-
FD86G
1 Pages
-
FD86T
1 Pages
-
FD80E
1 Pages
-
FD3051ST
1 Pages
-
FD3051S LA/LG
2 Pages
-
FD3051S LF
2 Pages
-
FD3051S LD
4 Pages
-
FD3051
1 Pages
-
FD3051S DP
1 Pages
-
FD80B
1 Pages
-
FDWC Temperature Switch
1 Pages