Catalog excerpts
High voltage power supply X-RAY GENERATOR OPTIONAL USB2.0,RS-232 OR RS-485 IS AVAILABLE. OUTPUT VOLTA GE FROM 10kV TO 30kV ADJUSTABLE INTEGRATED FILAMENT SUPPLY OVER VOLTAGE & SHORT CIRCUIT PROTECTION VOLTAGE & CURRENT PROGRAMMING. LOCAL AND REMOTE CONTROL. SAFETY INTERLOCK. OEM CUSTOMIZATION AVAILABLE. INTRODUCTION Wisman's XRA series of X-ray generator is a dedicated high stability modular high voltage power supply, XRA modular high voltage power supply is ideal for OEM. The maximum output voltage 10kV~30kV,maximum power 6W~100W . XRA series are a compact, integrated X-ray tube filament power supply adjustable between 0~3.5A at 0~5.5V. XRA series are provided Arc, short circuit, overload protection and safety interlock function. Optional USB2.0, RS-232 or RS-485 digital interface. TYPICAL APPLICATIONS Grounded cathode X-ray tubes from Kevex, Oxford, RTW, Superior, Varian and Trufocus .Thickness, ESD,Sulfur-detector X-ray fluorescence instrument, X-ray imaging, X-ray diffractometer,,Non-destructive testing, Portable X-ray machine, Rohs detector,Precious metal detector, Life Science,Medical industry,Science experiment and so on. XRA SELECTION TABLE ) 2019.2 Wisman High Voltage Power Supply Corp. All Rights Reserved ______
Open the catalog to page 1High voltage power supply ) 2019.2 Wisman High Voltage Power Supply Corp. All Rights Reserved 020219
Open the catalog to page 2X-RAY GENERATOR HAZARDOUS VOLTAGE PRESENT. TO REDUSE THE RISK OF ELECTRIC SHOCK. DO NOT DISCONNECT CABLE UNTIL 5 MINUTES HAVE ELAPSED AFTER TURNING OFF EQUIPMENT. FAILURE TO COMPLAY MAY CAUSE SEVERE INJURY OF DEATH FOR CONTINUED PROTECTION. AGAINST RISK OF FIRE.REPLACE ONLY WITH SAME TYPE AND RATING FUSE FAN (15CFM) Customer Mounting Holes M4×8mm Max Depth 0.276[7.0] Customer Mounting Holes M4×8mm Max Depth HAZARDOUS VOLTAGE PRESENT. TO REDUSE THE RISK OF ELECTRIC SHOCK. DO NOT DISCONNECT CABLE UNTIL 5 MINUTES HAVE ELAPSED AFTER TURNING OFF EQUIPMENT. FAILURE TO COMPLAY MAY CAUSE SEVERE...
Open the catalog to page 3HAZARDOUS VOLTAGE PRESENT. TO REDUSE THE RISK OF ELECTRIC SHOCK. DO NOT DISCONNECT CABLE UNTIL 5 MINUTES HAVE ELAPSED AFTER TURNING OFF EQUIPMENT. FAILURE TO COMPLAY MAY CAUSE SEVERE INJURY OF DEATH FOR CONTINUED PROTECTION. AGAINST RISK OF FIRE.REPLACE ONLY WITH SAME TYPE AND RATING FUSE (15CFM) Customer Mounting Holes M4×8mm Max Depth Customer Mounting Holes M4×8mm Max Depth HAZARDOUS VOLTAGE PRESENT. TO REDUSE THE RISK OF ELECTRIC SHOCK. DO NOT DISCONNECT CABLE UNTIL 5 MINUTES HAVE ELAPSED AFTER TURNING OFF EQUIPMENT. FAILURE TO COMPLAY MAY CAUSE SEVERE INJURY OF DEATH FOR CONTINUED...
Open the catalog to page 4X-RAY GENERATOR HAZARDOUS VOLTAGE PRESENT. TO REDUSE THE RISK OF ELECTRIC SHOCK. DO NOT DISCONNECT CABLE UNTIL 5 MINUTES HAVE ELAPSED AFTER TURNING OFF EQUIPMENT. FAILURE TO COMPLAY MAY CAUSE SEVERE INJURY OF DEATH FOR CONTINUED PROTECTION. AGAINST RISK OF FIRE.REPLACE ONLY WITH SAME TYPE AND RATING FUSE fan (15CFM) Customer Mounting Holes M4×8mm Max Depth Customer Mounting Holes M4×8mm Max Depth HAZARDOUS VOLTAGE PRESENT. TO REDUSE THE RISK OF ELECTRIC SHOCK. DO NOT DISCONNECT CABLE UNTIL 5 MINUTES HAVE ELAPSED AFTER TURNING OFF EQUIPMENT. FAILURE TO COMPLAY MAY CAUSE SEVERE INJURY OF...
Open the catalog to page 5All Shaanxi Wisman High Voltage Power Supply catalogs and technical brochures
-
MSE Series
2 Pages
-
MSD Series
2 Pages
-
MSC Series
2 Pages
-
MSB Series
2 Pages
-
MSA Series
2 Pages
-
WSM50501 Series
2 Pages
-
WSM169 Series
1 Pages
-
WSM168 Series
1 Pages
-
WSM166
1 Pages
-
WS10-40 Series
1 Pages
-
V8 Series
2 Pages
-
V6 Series
2 Pages
-
USB,RS-232 Series
1 Pages
-
RVD Series
1 Pages
-
CB100C3 Series
1 Pages
-
CB75C4 Series
1 Pages
-
CA100C3 Series
1 Pages
-
CA75C4 Series
1 Pages
-
CA75C3 Series
1 Pages
-
CA60 Series
1 Pages
-
SEM Series
3 Pages
-
PRF Series
3 Pages
-
PRE Series
3 Pages
-
PRC Series
3 Pages
-
PRB Series
3 Pages
-
PRA Series
3 Pages
-
PMA Series
3 Pages
-
PF Series
2 Pages
-
HEM Series
2 Pages
-
FF Series
2 Pages
-
EMA Series
3 Pages
-
EM Series
4 Pages
-
EIB Series
3 Pages
-
ECD Series
2 Pages
-
ECA Series
3 Pages
-
EC Series
3 Pages
-
BA Series
2 Pages
-
B Series
3 Pages
-
3DA Series
3 Pages
-
3D Series
3 Pages
-
ZA Series
2 Pages
-
AMX Series
2 Pages
-
AMW Series
3 Pages
-
AMU Series
2 Pages
-
AMT Series
2 Pages
-
AMS Series
2 Pages
-
AMR Series
2 Pages
-
AMN Series
2 Pages
-
AML Series
2 Pages
-
AMK Series
2 Pages
-
AME Series
2 Pages
-
TC Series
4 Pages
-
TB Series
4 Pages
-
TA Series
4 Pages
-
SDL Series
4 Pages
-
SDG Series
4 Pages
-
SDF Series
4 Pages
-
S Series
1 Pages
-
DR Series
3 Pages
-
DL Series
3 Pages
-
DH Series
3 Pages
-
DG Series
5 Pages
-
DF Series
3 Pages
-
DE Series
3 Pages
-
DC Series
3 Pages
-
DA Series
2 Pages
-
DEL Series
2 Pages
-
DEF Series
3 Pages
-
DED Series
2 Pages
-
DEC Series
2 Pages
-
DEA Series
2 Pages
-
XWA Series
3 Pages
-
XW Series
4 Pages
-
XRW Series
3 Pages
-
XRN Series
3 Pages
-
XRL Series
3 Pages
-
XRH Series
3 Pages
-
XRG Series
3 Pages
-
XRF Series
3 Pages
-
XRD Series
6 Pages
-
XRC Series
3 Pages
-
XRB Series
3 Pages
-
XNA Series
3 Pages
-
XN Series
3 Pages
-
XFN Series
3 Pages
-
XFL Series
4 Pages
-
XEL Series
2 Pages
-
XDF Series
3 Pages
-
XDB Series
3 Pages
-
XAA Series
3 Pages
-
XA Series
2 Pages
-
NDT Series
4 Pages
-
PMS Series
3 Pages
-
PMD Series
3 Pages
-
PMC Series
3 Pages
-
PMB Series
3 Pages
-
PM Series
3 Pages
-
MT Series
3 Pages
-
MRW Series
3 Pages
-
MRS Series
2 Pages
-
MRN Series
3 Pages
-
MRL Series
3 Pages
-
MRD Series
5 Pages
-
MRC Series
3 Pages
-
MRB Series
3 Pages
-
MRA Series
4 Pages
-
MN Series
3 Pages
-
MEF Series
3 Pages
-
MEB Series
2 Pages
-
ME Series
3 Pages
-
DNA Series
2 Pages
-
MUD Series
2 Pages
-
MUB Series
2 Pages
-
MBA Series
2 Pages
-
MB Series
2 Pages
-
MUC Series
5 Pages
-
MUA Series
2 Pages
-
MU Series
3 Pages
-
MMC Series
2 Pages
-
MMB Series
2 Pages
-
MMA Series
2 Pages
-
MM Series
2 Pages
-
MG Series
2 Pages
-
MFA Series
2 Pages
-
MF Series
2 Pages
-
MDC Series
2 Pages
-
MDA Series
2 Pages
-
MCP Series
2 Pages
-
MCE Series
1 Pages
-
MCC Series
2 Pages
-
MCA Series
2 Pages
-
MC Series
2 Pages
-
MA Series
2 Pages
-
BP Series
1 Pages
-
DEA
2 Pages
-
XA
2 Pages
-
PM
3 Pages
-
MB
2 Pages