Plasmaconnect_10

Plasmaconnect_10

Plasmaconnect_10

Product catalog summary
Description
PlasmaConnect 10 is a cutting-edge technology utilizing non-thermal plasma (NTP) for advanced oxidation in water and wastewater treatment. It effectively removes hard-to-degrade organic substances like drug residues, hormones, pesticides, and herbicides, as well as oxidizes inorganic substances such as metals. The process also disinfects and decolorizes, enhancing the microbiological quality of water. It is applicable in various areas, including wastewater and drinking water treatment and water reuse.
C-ION™ Plasma Unit Specifications
- Plasma Generation: Dielectric barrier discharge (DBE)
- Plasma Type: Non-thermal (cold) plasma
- Dimensions: 700 x 180 x 125 mm
- Weight: 5.5 kg
- Connections: Air inlet and plasma outlet DN40
Product Specifications
- Number of Plasma Units: 10
- Piping: PVC-U / Stainless steel 304/304L
- Frame: Stainless steel 304/304L
- Dimensions: 1150 x 800 x 1959 mm
- Weight: Approx. 250 kg
- Connections: Plasma outlet DN40
Feed Requirements
- Temperature Range: 4 – 40 °C
- Air Humidity: < 70%
Operation Information
- Blower: 48 m³/h; 250 mbar
- Power Supply: 400V / 50Hz (3-phase)
- Power: 2.5 kW
- Max. Diffusor Depth: 2 m
- Max. Cleaning Capacity: 50 m³/h (depending on contamination level)
- Inlet and outlet should be at opposite ends to avoid short circulation
- Plasma hose should be kept short for efficiency
- Connecting parts must be ozone resistant
- Oxidation tank should be closed with exhaust air openings
Product Highlights
- Ready-to-connect base unit with control panel
- High oxidation potential with hydroxyl radicals
- Lower energy consumption compared to other processes
- No additional cooling, special explosion, or emission containment required
- No chemical consumables or supply air treatment needed
- Easy retrofitting of existing tanks
Included Aeration Package
- 10 Disc diffusers: 12” x 70 mm; 1.35 kg; connection: 1”
- 10 Concrete base plates: 320 x 220 x 70 mm; 9.6 kg; connection: 16 mm
Optional Packages
- Reaction tank with level control
- System integration into building management
Disclaimer
The information is accurate and reliable but does not confer any warranty or guarantee of performance. Dimensions and membrane geometry may change due to production and process enhancements. No liability is assumed for outcomes or damages from using the unit.
See more

Catalog excerpts

Plasmaconnect_10-1

Umwelttechnik Clean Water. Engineered for the World. Product Data Sheet DESCRIPTION PlasmaConnect is an innovative and future-oriented technology for advanced oxidation based on ionized air - known as non-thermal plasma (NTP). Due to its high efficiency, easy integration, and broad effectiveness against a wide range of pollutants, C-ION™ technology sets new standards in modern water treatment. It removes even difficult-to-degrade organic substances such as drug residues, hormones, pesticides, and herbicides, and oxidizes inorganic substances such as metals (iron, manganese, and arsenic). In addition, the process has a disinfecting and decolorizing effect and contributes to a lasting improvement in the microbiological quality of water. PlasmaConnect is used in numerous areas - from wastewater and drinking water treatment to water reuse. Number ofplasmannits: Piping: FEED REQUIREMENTS Temperature range: OPERATION Blower: INFORMATION Power supply: max. Diffusordepth: max. cleaning appacity: Please also note: C-ION™ PLASMA UNIT Plasma generation: Plasma type: Dimension: PRODUCTSPECIFICATION Dieleatricbarrier diataare e(DBE) Non-thermal (cold) plasma 700 x180 x125 mm Air inlet: DN40 Plasma outlet: DN40 PVC-U / Stainless steel 304/304L Stainletsstee I304/304L 1150 x 800 x 1959 mm approx. 250 kg Plasmaoutleh :DN40 ’depending on the degree of contamination Inlet and outlet at opposite ends of the tank to avoid short circulation Keep the plasma hose as short as possible (efficiency reduction) Connectrngpatts must! oozoxetesistant The oxidation tank must be designed as a closed system with exhaust air openings. Ozone enrichment is possible in the oxidation tank. SFC Umwelttechnik GmbH | Julius-Welser-Str. 15 | 5020 Salzburg | Austria Tel.: +43 (0) 662 / 43 49 02 | Mail: [email protected] Website: www.sfcu.at

 Open the catalog to page 1
Plasmaconnect_10-2

Ready -to-connect base unit including control panel High oxidation potential (2.75 V through the formation of hydroxyl radicals, reaction rate 2.2∙107 to 1.8∙1010 M-1s-1) Lower energy consumption compared to other oxidation processes, e.g., ozone No additional cooling required No special explosion or emission containment measures required No chemical consumables required No supply air treatment required Easy retrofitting of existing tanks possibl INCL. AERATION PACKAGE 10 Disc diffuser: 12“ x 70 mm; 1.35 kg; connection: 1” 10 Concrete base plate: 320 x 220 x 70 mm; 9.6 kg; connection: 16 mm OPTIONAL...

 Open the catalog to page 2

All SFC Umwelttechnik GmBH catalogs and technical brochures

  1. C-MEM™ ZERO

    2  Pages

  2. Membraloop™

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.