800-257-3872 159 Swanson Rd., Boxborough, MA 01719/Telephone: 978-263-1400/Fax: 978-264-0292 Multi-SenseTM Series - Model 260 Very Low Differential Multi-Confi gurable Pressure Transducer Unidirectional Ranges: 0.1 - 10 in. W.C. to .25 - 2.5 kPa FS Bidirectional Ranges: ±0.1 - 10 in. W.C. to ±.25 - 2.5 kPa FS Air or Non-Conducting Gas Visit Setra Online: http://www.setra.com ments. The units are temperature compsensated to within ±0.03%FS/oF (0.054%FS/oC) for zero and span. The Model 260 utilizes an all stainless steel micro-tig welded sensor. The tensioned stainless steel diaphragm and insulated stainless steel electrode, positioned close to the diaphragm, form a variable capacitor. Positive pressure moves the diaphragm toward the electrode, increasing the capacitance. A decrease in pressure moves the diaphragm away from the electrode, decreasing the capacitance. The change in capacitance is detected and converted to a linear DC electrical signal by Setra’s custom ASIC technology. Target Users œ Service/Retrofi t Friendly œ Small Users - Inventory & Installation Savings œ Sub-Contractors - Quick Installation œ Flexible for Building Specifi cation Changes œ Service Technicians- Quick and Accurate Reconfi gurations Features ¡ Optional 4 Digit LCD ¡ Field Selectable Multi- Range ¡ Field Selectable Multi- Output ¡ Simple 5-Step Setup ¡ Field Accessible Push Button Zero and Span ¡ Hinged Cover ¡ External Mounting Tabs ¡ Unregulated AC/DC Operation ¡ Microprocessor Based Electronics - Guarantees Range to Range Performance ¡ NIST Traceable ¡ Fire Retardant Case (UL 94 V-0 Approved) ¡ Meets CE Conformance Standards ¡ Fully RoHS Compliant Setra Systems 260 pressure transducers sense differential or gauge (static) pres sure and convert this pressure difference to a proportional electrical output for either fi eld selectable unidirectional or bidirectional pressure ranges. The 260 Series is offered with fi eld selectable high level analog outputs of 0 to 5, and 0 to 10 VDC, or 4 to 20 mA. Used in Building Energy Management Systems, these transducers are capable of measuring pressures and flows with the performance necessary for proper building pressurization and air fl ow control. The 260 Series transducers can be confi gured for air pressure ranges as low as 0.1 in. W.C. full scale, with pascal ranges as low as 25 Pa full scale. Static standard accuracy is ±1.0% full scale in normal ambient temperature environ- Model Unidirectional Bidirectional MS1 0.1, 0.25, 0.5, 1.0 in. WC FS ±0.1, 0.25, 0.5, 1.0 in. WC FS MS2 1.0, 2.5, 5.0, 10 in. WC FS ±1.0, 2.5, 5.0, 10 in. WC FS MS3 25, 50, 100, 250 Pa FS ±25, 50, 100, 250 Pa FS MS4 .25, .50, 1.00, 2.5 kPa FS ±.25, .50, 1.00, 2.5 kPa FS Ranges Uni d irectional Optional Static Probe Designed with a Gasket to Seal Against the Duct. U.S. Patent nos. 4093915; 4358814; 4434203; 6019002; 6014800. Other Patents Pending.
Open the catalog to page 1Performance Data Thru All Field Selectable Ranges Standard Accuracy* RSS (at constant temp) ±1.0% FS Non-Linearity, BFSL ±0.96% FS Hysteresis 0.10% FS Non-Repeatability 0.05% FS Thermal Effects** Compensated Range °F (°C) 32 to 122°F (0 to 50°C) Zero/Span Shift %FS/°F(°C) 0.03 (0.054) Maximum Line Pressure 10 PSI Overpressure UP To 10 PSI (Range Dependent) Long Term Stability (max) 2.0% FS/YR Position Effect Zero Offset (%FS/G) 0.2% (Unit is factory calibrated at 0g effect in the vertical position.) * RSS of Non-Linearity, Hysteresis, and Non-Repeatability. **Units calibrated at nominal 70¢ªF....
Open the catalog to page 24 Pages
2 Pages
4 Pages
2 Pages
2 Pages
4 Pages
12 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
4 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages