SERVOTOUGH OxyExact 2200 Product Brochure
16Pages

{{requestButtons}}

Catalog excerpts

SERVOTOUGH OxyExact 2200 Product Brochure - 1

PRODUCT OVERVIEW S E R V O T O U G H OxyExact 2200 HAZARDOUS AREA HIGH-SPEC PROCESS O2 ANALYZER OFFERS SAFE OR HAZARDOUS AREA CONTROL WITH UP TO SIX TRANSMITTERS UNRIVALLED PERFORMANCE Uses industry-leading patented Paramagnetic technology for stable, non-depleting measurement GAS PROCESS CONTROL COMBUSTION SENSING TECHNOLOGY transmitters can be Six linked to a single control unit, allowing easy device interaction and set-up Manufactured by Servomex over 60 years’ experience innovating and pioneering gas analysis, and thousands of units used in the field every year Control unit enclosure allows integration of multiple option cards (4 configurable) FLEXIBLE Can be used in hazardous area rated locations including Zone 1 and Division 1 Samples flammable gas mixtures up to 100% O2 High pressure variant allows the handling of samples at 45psia (max) (limited to 21% O2 above 18psia) High temperature variant allows the handling of high dew point samples Digital communication options: Ethernet and RS485 Modbus KEY APPLICATIONS Oxidation control reactions Ethylene Oxide (EO), Pure Terephthalic Acid (PTA), and Ethylene Dichloride (EDC) manufacturing BENCHMARK COMPLIANCE ATEX, IECEx, CSA and FM for Zone 1 and Division 1 monitoring Catalyst regeneration Solvent recovery Learn more about the SERVOTOUGH OxyExact 2200 Internal pressure compensation option to monitor vent pressure variations coupled with high sample pressure option for flare stack applications Internal flow alarm option LOW COST OF OWNERSHIP need for reference/purge No gases during measurement in flammable samples Simplified transmitter interaction via intuitive control unit (hazardous area or safe area model variants) Rugged, resilient design helps ensure long operational life in harsh conditions Auto-validation and calibration

Open the catalog to page 1
SERVOTOUGH OxyExact 2200 Product Brochure - 2

PRODUCT OVERVIEW S E R V O T O U G H OxyExact 2200 UNRIVALLED PERFORMANCE FOR THE MOST DEMANDING O2 PROCESS MONITORING When you work in hazardous area process monitoring applications, a highly accurate, safe O2 analytical solution that samples any flammable gas mixture up to 100% O2 is crucial. No matter what your monitoring requirement, you need an analytical solution that offers operational flexibility, exceptional safety and the opportunity to reduce costs. We don’t believe you should have to compromise. HAZARDOUS AREA USEFUL LINKS A NO COMPROMISE SOLUTION The OxyExact’s sophisticated,...

Open the catalog to page 2
SERVOTOUGH OxyExact 2200 Product Brochure - 3

TECHNICAL DATA SHEET S E R V O T O U G OxyExact 2200 SERVOTOUGHH OxyExact 2200 Transmitter SPECIFICATIONS TRANSMITTER PERFORMANCE Measurement range Minimum recommended range Intrinsic error (accuracy) Zero drift per week Span drift per week Linearity error Response time (T90) Output noise (within any 5 minute period) Effect of ambient temperature changes <4 seconds at 250ml/min (low flow range) <4 seconds at 1l/min (high flow range) <0.01% O2 peak to peak Zero change per 10°C (18°F) ambient change ± 0.02% max Span change per 10°C (18°F) ambient change ± 0.2% max Sample flow variations A...

Open the catalog to page 3
SERVOTOUGH OxyExact 2200 Product Brochure - 4

Ingress protection Dimensions, WxDxH Wall mount OPERATING ENVIRONMENT Temperature Atmospheric pressure Warm up time 76 to 112kPaa (11 to 16.2psia) Useable immediately, but typically 2 hours (from 20°C) Relative humidity Typically 6 hours (from 20°C) SAMPLE CONDITION 2223 (standard) Maximum measurable oxygen concentration Inlet pressure Sample pressure (maximum) Inlet flow rate 250ml (air)/minute or 1l/min depending upon version 250ml (air)/minute or 1l/min depending upon version 250ml (air)/minute or 1l/min depending upon version 5°C (9°F) below lowest ambient temp 5°C (9°F) below lowest...

Open the catalog to page 4
SERVOTOUGH OxyExact 2200 Product Brochure - 5

SAMPLE WETTED MATERIALS TRANSMITTER Borosilicate glass Electroless Nickel Platinum Platinum/iridium alloy 316 stainless steel Hastelloy Viton® PTFE Chemraz® COMPLIANCE HAZARDOUS AREA APPROVALS TRANSMITTER ATEX (Europe) Class I, Division 1, Groups A,B,C and D Class II, Division 1, Groups E, F and G Class III, Division 1 T4, ambient temperature 50°C maximum Class I, Division 1, Groups A,B,C and D Class II, Division 1, Groups E,F and G Class III, Division 1 T3, ambient temperature 50°C maximum Class I, Zone 1 approval, AEx d ia IIC T4 (Ta = 50°C) Class I, Zone 1 approval, AEx d ia IIC T3 (Ta =...

Open the catalog to page 5
SERVOTOUGH OxyExact 2200 Product Brochure - 6

TRANSMITTER configuration Transmitter versions There are two versions of the OxyExact 2200. The 2223 measurement compartment is controlled at 60°C, whilst the 2222 measurement compartment operates at 110°C. The higher sample compartment temperature of the 2222H results in some options not being available for this transmitter unit. Transmitter type 5 certified versions of the Oxy analyzer are available for the 2233 transmitter version: European ATEX, International IECEx, North American FM, Canadian CSA and Japanese. Japanese certification is not available for the 2222H. Refer to...

Open the catalog to page 6
SERVOTOUGH OxyExact 2200 Product Brochure - 7

SERVOTOUGH OxyExact Transmitter 2223 Transmitter type Hazardous Area ATEX Cat 2 (Zone 1) Hazardous Area FM Div 1 Hazardous Area CSA Div 1 IEC Ex CML Ex Supply voltage User manual Service manual Electrical entry option Sample wetted material Stainless steel Hastelloy Sample cell type Standard High pressure solvent resistant Sample flow Internal sample filter Flow alarm Fitted, internal Pressure compensation Fitted, internal Sample inlet adaptors Standard (1/8" NPT (F)) 1/4" OD adaptor 6mm OD adaptor Corrosive sample purge Functional safety/SIL manual

Open the catalog to page 7
SERVOTOUGH OxyExact 2200 Product Brochure - 8

SERVOTOUGH OxyExact Transmitter 2222 (High Temperature) Transmitter type Hazardous Area ATEX Cat 2 (Zone 1) Hazardous Area FM Div 1 Hazardous Area CSA Div 1 IEC Ex Sample temperature Supply voltage User manual Service manual Electrical entry option Sample wetted material Stainless steel Sample cell type High pressure solvent resistant Sample flow Internal sample filter Flow alarm Sample inlet adaptors Corrosive sample purge Functional safety/SIL manual

Open the catalog to page 8
SERVOTOUGH OxyExact 2200 Product Brochure - 9

DIMENSIONAL DRAWINGS TRANSMITTER UNIT Sample gas connections Power cable entry Functional (EMC) earth/ground terminal Signal cable entry Signal cable entry Signal cable entry Signal cable entry Corrosive purge gas outlet Corrosive purge gas inlet Dimensions shown in millimetres Sample gas connections Power cable entry Functional (EMC) earth/ground terminal Signal cable entry Signal cable entry Signal cable entry Signal cable entry Corrosive purge gas outlet Corrosive purge gas inlet

Open the catalog to page 9

All SERVOMEX catalogs and technical brochures

Archived catalogs