Product overview Sampling system for Servomex paramagnetic oxygen analyzers For use with: SERVOTOUGH OxyExact 2200 The SERVOTOUGH OxyExact high specification O2 analyzer offers an unrivalled combination of precision, flexibility and performance for optimum process and safety control. The OxyExact can be configured with a hazardous area control unit with up to six transmitters. Application Process control Process safety SENSING TECHNOLOGY Wet samples Indoor and sheltered outdoor locations Standard output flow rate For more information visit servomex.com/contact

Open the catalog to page 1
SERVOTOUGH 1162A (2232) Wet Gas Sampling System Product Brochure - 2

1162A (2232) Wet Gas Sampling System A no compromise solution The 1162A Wet Gas Sampling System is designed to complement the range of Servomex process analysers and provide a stable sample flow optimised to ensure the fundamental Analyser performance is not degraded. Product overview Useful links: Unbeatable value The 1162A presents a cost effective solution that’s sits between the need to present a clean, dry gas to the paramagnetic analyser and an incoming sample gas with a low level of entrained condensate (typically less than 0.5ml liquid per litre of gas). Performance you can depend...

Open the catalog to page 2
SERVOTOUGH 1162A (2232) Wet Gas Sampling System Product Brochure - 3

Technical Data Sheet 1162A (2232) Wet Gas Sampling System Specifications Performance Sample flow rate By-pass flow rate <14 seconds (includes analyzer) ‘Dirty’ samples must be prefiltered by an external large area filter Sample conditions Sample inlet pressure** Maximum entrained condensate load 0.5ml of liquid per litre of gas Operating environment Temperature range Ambient pressure Physical Connections * With by-pass flow of 400ml/min and sample flow of 200ml/min ** Bubbler must vent to atmosphere pressure *** Below 0°C water in the bubbler should be replaced by ethylene glycol Sample...

Open the catalog to page 3
SERVOTOUGH 1162A (2232) Wet Gas Sampling System Product Brochure - 4

We’re ready to help Whatever your gas analysis requirements, wherever you are. These analyzers are not intended for any form of use on humans and are not medical devices as described in the Medical Devices legislation or regulation. Please note: Whilst every effort has been made to ensure accuracy, no responsibility can be accepted for errors and omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards and guidelines. This document is not intended to form the basis of a contract. Servomex has a...