SERVOTOUGH 1162A (2232) Wet Gas Sampling System Product Brochure
4Pages

{{requestButtons}}

Catalog excerpts

SERVOTOUGH 1162A (2232) Wet Gas Sampling System Product Brochure - 1

PRODUCT OVERVIEW S E R V O T O U G H 1162A (2232) Wet Gas Sampling System SAMPLING SYSTEM FOR SERVOMEX PARAMAGNETIC OXYGEN ANALYZERS FOR USE WITH: SERVOTOUGH Oxy 1800 Designed to reliably measure percent O2 in many industrial applications, the SERVOTOUGH Oxy 1800 is a stable, accurate and highly specific O2 analyzer for safe area use GAS PROCESS CONTROL SAFETY SENSING TECHNOLOGY SERVOTOUGH OxyExact 2200 The SERVOTOUGH OxyExact high specification O2 analyzer offers an unrivalled combination of precision, flexibility and performance for optimum process and safety control. The OxyExact can be configured with a hazardous area control unit with up to six transmitters PROCESS CONTROL SENSING TECHNOLOGY Indoor and sheltered outdoor locations Standard output flow rate Learn more about the 1162A Wet Gas Sampling System

Open the catalog to page 1
SERVOTOUGH 1162A (2232) Wet Gas Sampling System Product Brochure - 2

PRODUCT OVERVIEW S E R V O T O U G H 1162A (2232) Wet Gas Sampling System A NO COMPROMISE SOLUTION USEFUL LINKS The 1162A Wet Gas Sampling System is designed to complement the range of Servomex process analysers and provide a stable sample flow optimised to ensure the fundamental Analyser performance is not degraded. servomex.com/service UNBEATABLE VALUE The 1162A presents a cost effective solution that’s sits between the need to present a clean, dry gas to the paramagnetic analyser and an incoming sample gas with a low level of entrained condensate (typically less than 0.5ml liquid per...

Open the catalog to page 2
SERVOTOUGH 1162A (2232) Wet Gas Sampling System Product Brochure - 3

TECHNICAL DATA SHEET 1162A (2232) Wet Gas Sampling System SERVOTOUGH Oxy 1900 SPECIFICATIONS PERFORMANCE Sample flow rate By-pass flow rate 90% retention of 0.6mm particles ‘Dirty’ samples must be prefiltered by an external large area filter <14 seconds (includes analyzer) sample conditions Sample inlet pressure** Maximum entrained condensate load 0.5ml of liquid per litre of gas operating environment Temperature range Ambient pressure PHYSICAL Connections * With by-pass flow of 400ml/min and sample flow of 200ml/min ** Bubbler must vent to atmosphere pressure *** Below 0°C water in the...

Open the catalog to page 3
SERVOTOUGH 1162A (2232) Wet Gas Sampling System Product Brochure - 4

WE’RE READY TO HELP WHATEVER YOUR GAS ANALYSIS REQUIREMENTS, WHEREVER YOU ARE These analyzers are not intended for any form of use on humans and are not medical devices as described in the Medical Devices Directive 93/42EEC. Please note: Whilst every effort has been made to ensure accuracy, no responsibility can be accepted for errors and omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards and guidelines. This document is not intended to form the basis of a contract. Servomex has a policy of...

Open the catalog to page 4