Product overview Safe area The PureGas is a getter-based unit designed for the purification of carrier gases (helium and argon) and other analytical applications Standard features Outlet impurity levels for O2, H2O, CO, CO2, H2, CH4 and N2 are reduced to low parts per billion (ppb) levels or below. The patented Getter alloy operated at elevated temperatures, removes impurities by forming irreversible chemical bonds. Impurities will not be released under any circumstances when the purifier is operated within specification. Deep blue anodized exterior maintains a 45ºC/113ºF surface temperature Efficient ceramic fiber insulation with encapsulated heater coil 20μm sintered filter on inlet and outlet 1/8” compression fittings (optional 1/8” VCR) Process gas specification Max flow rate (maximum purified gas delivered) Nominal flow rate Minimum flow rate* Maximum inlet pressure Maximum pressure drop at 6.2barg (90psig) inlet pressure and maximum rated flow Inlet gas temperature (min-max) Outlet gas temperature (maximum) * The minimum flow is the lowest flowrate at which Servomex will guarantee that outlet gas purity will be met as well as the minimum flow that must be available from the supply to comply with the specification. Useful links servomex.com/service Key applications Purification of carrier gases for gas chromatography (GC) Other analytical applications where ultra high purity helium or argon are required For more information visit servomex.c
Open the catalog to page 1Technical data sheet SERVOPRO PureGas Specifications Facilities requirements electrical Installed power (Customer to specify voltage at time of order) Plug style (customer to specify which power plug is required in their area at time of order) Facilities requirements general Indoor installation, ambient temperature (min-max) Performance Inlet purity requirements (5.0 gas) Outlet purity level (1/8" swg) Outlet purity level (1/8" VCR) Utilities Feed gas inlet 1/8” Swagelok fittings (optional 1/8” VCR) 1/8” Swagelok fittings (optional 1/8” VCR) Heater power consumption Particulate filter 20μm sintered...
Open the catalog to page 2Dimensional drawings Overall and fixing dimensions - standard Overall and fixing dimensions - VCR
Open the catalog to page 3We’re ready to help Whatever your gas analysis requirements, wherever you are. These analyzers are not intended for any form of use on humans and are not medical devices as described in the Medical Devices legislation or regulation. Please note: Whilst every effort has been made to ensure accuracy, no responsibility can be accepted for errors and omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards and guidelines. This document is not intended to form the basis of a contract. Servomex has a policy...
Open the catalog to page 474 Pages
14 Pages
12 Pages
9 Pages
16 Pages
10 Pages
144 Pages
112 Pages
11 Pages
19 Pages
11 Pages
11 Pages
11 Pages
15 Pages
11 Pages
11 Pages
11 Pages
13 Pages
182 Pages
112 Pages
90 Pages
87 Pages
82 Pages
146 Pages
134 Pages
2 Pages
7 Pages
15 Pages
13 Pages
76 Pages
4 Pages
4 Pages
13 Pages
11 Pages
77 Pages
2 Pages
2 Pages
2 Pages
65 Pages