Product overview Safe area Trusted by plant operators and engineers for over 20 years for the analysis of flammable gas samples and trace contaminants in HyCO, syngas and gas transfer applications* Unrivalled performance Gas Process control SENSING TECHNOLOGY Industry-leading, patented Paramagnetic and GFx IR technologies for ultrastable, accurate and selective measurements Manufactured by Servomex - over 70 years’ experience innovating and pioneering gas analysis and thousands of units used in the field every year Flexible Measures % O2 and trace level CO, CO2, N2O, CH4 Measures up to four flammable gas streams simultaneously External analog input facility Easy to use Intuitive integrated LCD interface Alarm, fault and calibration history logs Simple calibration Low cost of ownership Reduced ongoing operational needs via automatic calibration option Benchmark compliance In compliance with Low Voltage, EMC and applicable EU Directives Suitable for use with potentially flammable samples RS232/RS485 data output and Modbus communications Key applications Product quality validation in hydrogen plants HyCO process control Syngas analysis Bottling/filling plants producing flammable gas blends * The MultiExact 4200 is the second generation of 4200 Series analyzers from Servomex, which reliably served industry for over 20 years For more information visit servomex.com/contact
Open the catalog to page 1
MultiExact 4200 Unsurpassed performance When you work in flammable gas production, you need an analytical solution that can adapt to varying sampling needs, with the highest performance provision and reliability. The flexibility to measure percent and trace gas levels is imperative as is the ability to monitor multiple gas streams simultaneously. No matter what your application requirements, you’ll want a flexible, feature-rich device that reduces ongoing costs. We don’t believe you should have to compromise. A no compromise solution The MultiExact 4200 is specifically designed to address...
Open the catalog to page 2
Technical data sheet SERVOPRO MultiExact 4200 Specifications Gas measured Paramagnetic and Infrared (GFx) for other gases Accuracy (intrinsic error) Zero drift/week Signal outputs/inputs Analog output Per measurement: 1 x 4-20mA (standard), 2 x 4-20 mA per transducer optional with addition of extra option board for 2 transducers, 1 x 0-10V (optional) Analog input Digital input Up to 8 digital inputs (2 per transducer) 4 relays as standard (8 with autocal), up to 32 relays, 30V (dc or ac) /1A 2 alarms as standard, up to 32 alarms Digital communications RS232/RS485 Modbus, PROFIBUS, Ethernet...
Open the catalog to page 3
Operating environment Operating temperature Storage temperature Ambient pressure range Relative humidity -500m (below sea level) to 2000m (above sea level) Warm-up time Warm up time is typically <20 minutes from cold start at 20oC (68oF), may be longer for the higher sensitivity measurements with heaters. Thermal stability is typically 24 hours. Utilities Power Sample wetted materials 303 stainless steel 316 stainless steel Viton® Borosilicate glass Platinum Platinum/iridium alloy Electroless nickel Gold Control paramagnetic 1210 Series GFx NDIR transducer Calcium fluoride Nickel This...
Open the catalog to page 4
Dimensional drawings Dimensions shown in millimetres
Open the catalog to page 5
Options NOTE Some module and option combinations are not available. Please consult Servomex. Analyzer configuration Configurable alarms O2 Control 0-5/100vpm CO2 0-50/500vpm CO 0-50/500vpm N2O 0-50/500vpm CH4 Two alarms (standard) Four alarms Eight alarms Isolated analog output Dual analog output Single (standard) Dual Digital input Isolated analog input Please tick the box for required Module 1 & 2 options Analyzer configuration Measurement Configurable alarms O2 Control Two alarms (standard) Four alarms Eight alarms Isolated analog output Dual analog output Single (standard) Dual Digital...
Open the catalog to page 6
Options General configuration Power cord Flow alarm Not required Fitted to module 1 Fitted to module 2 (coming soon) Serial communications Not required RS232 communication RS485 communication w/Modbus RS232 & RS485 comm combo Bench top Rack mount w/ears Rack mount w/slides Relay contacts 4 relay contacts (standard) 8 relay contacts w/connectors 16 relay contacts w/connectors 24 relay contacts w/connectors 32 relay contacts w/connectors Operator manual Please tick the box for required options
Open the catalog to page 7
We’re ready to help Whatever your gas analysis requirements, wherever you are. These analyzers are not intended for any form of use on humans and are not medical devices as described in the Medical Devices legislation or regulation. Please note: Whilst every effort has been made to ensure accuracy, no responsibility can be accepted for errors and omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards and guidelines. This document is not intended to form the basis of a contract. Servomex has a...
Open the catalog to page 8All SERVOMEX catalogs and technical brochures
-
Service Guide Issue 4
13 Pages
-
Product Guide Issue 9
15 Pages
-
Gas Guide Issue 5
74 Pages
-
SERVOTOUGH OxyExact 2200
16 Pages
-
SERVOPRO 4900 Multigas
10 Pages
-
SERVOPRO PureGas
4 Pages
-
Servomex Product Portfolio
2 Pages
-
DF560E Operator Manual
144 Pages
-
DF-745 Operator Manual
112 Pages
-
ES 39 Sustainability
11 Pages
-
ES 38 Korea Special
19 Pages
-
ES 37 Clean Air part II
11 Pages
-
ES 36 Purity & Specialty
11 Pages
-
ES 35 Photometric Analysis
11 Pages
-
ES 34 70th Anniversary
15 Pages
-
ES30 Air Separation Units
11 Pages
-
ES 29 Clean Air
11 Pages
-
ES 28 Gas Analysis Applications
11 Pages
-
Sensing Technologies
13 Pages
-
DF760E Operator Manual
182 Pages
-
DF750 Operator Manual
112 Pages
-
DF745SGMax Operator Manual
90 Pages
-
DF-740 Operator Manual
87 Pages
-
DF-730 Operator Manual
82 Pages
-
DF560E Operator Manual 082616
146 Pages
-
DF550E Operator Manual 082616
134 Pages
Archived catalogs
-
SERVOFLEX MiniMP 5200
7 Pages
-
Servomex Gas Guide - Issue 4
76 Pages
-
Servomex Product Guide - Issue 8
15 Pages
-
Servomex Service Guide - Issue 3
13 Pages
-
SERVOTOUGH SpectraScan 2400
2 Pages
-
SERVOTOUGH H2 Scan
2 Pages
-
SERVOPRO NOx
4 Pages
-
SERVOPRO HFID
4 Pages
-
Servomex Service Portfolio
2 Pages
-
Servomex GAS GUIDE issue 3
77 Pages
-
Servomex Service Guide Issue 2
11 Pages
-
Servomex Product Guide Issue 7
13 Pages
-
Servomex Gas Guide 2022
65 Pages