Group: Spectris
Catalog excerpts
PRODUCT OVERVIEW S E R V O P R O MultiExact 4100 SAFE AREA A DIGITAL, NEXT-GENERATION MULTI-GAS ANALYZER DESIGNED TO PROVIDE A HIGHLY ADAPTABLE ANALYSIS SOLUTION FOR INDUSTRIAL AND MEDICAL GAS MANUFACTURERS UNRIVALLED PERFORMANCE PROCESS CONTROL SENSING TECHNOLOGY Uses industry-leading, ultra-sensitive and reliable Paramagnetic, GFx Infrared, SBSW Infrared, Zirconia and Aluminum Oxide sensing technologies Intuitive icon-driven user interface with color touchscreen USB serial port for data logging and software upgrades Analyzer configurations can be easily transferred to other analyzers via USB thumb drive Third generation platform building on more than 60 years of Servomex experience Restless innovating will have new sensors available soon FLEXIBLE Field upgradeable relay, alarm and communication protocols Download and email system files to leverage our remote service expertise Measures up to four gas streams simultaneously Uses ultra-stable, non- depleting digital sensing technologies that help extend maintenance intervals Integrated support for the AquaXact 1688 Aluminum Oxide moisture transmitter ALUMINUM OXIDE Auto-calibration function helps to reduce operational osts c Digital communications for remote access: RS232/RS485 Modbus, PROFIBUS, and Ethernet (Modbus TCP/IP) KEY APPLICATIONS Product purity on air separation plant Process control on air separation plant Up to 32 alarms and 32 relays with follow or freeze options Four analog outputs and four analog inputs Monitor trace CO2 on scrubbed air inlet to air separation process Validation of medical O2, N2, air and He Mobile labs Learn more about the SERVOPRO MultiExact 4100 Plug and play sensor replacement Commonly integrated in to multiple stream switching systems BENCHMARK COMPLIANCE USP and European Pharmacopoeia compliant method for assay of medical oxygen and medical air In compliance with Low Voltage, EMC and applicable EU Directives - CSA Certification pending
Open the catalog to page 1PRODUCT OVERVIEW S E R V O P R O MultiExact 4100 HIGH RELIABILITY AND UNRIVALLED PERFORMANCE With a strong combination of features and benefits, the MultiExact 4100 is a highly adaptable analysis solution that meets a range of needs. It uses a wide range of Servomex’s proven, reliable and accurate sensing technologies to provide up to four simultaneous gas stream measurements, meeting the challenges faced by industrial and medical gas manufacturers. With flexible analysis solutions capable of meeting specific process monitoring needs, the MultiExact 4100 delivers precise, stable results at...
Open the catalog to page 2TECHNICAL DATA SHEET S E R V O P R O MultiExact 4100 SPECIFICATIONS gas measured Paramagnetic and Zirconia for O2, SBSW IR and Infrared (Gfx) for other gases Gas Technology Range Accuracy (intrinsic error) Zero drift/week Range Accuracy (intrinsic error) Zero drift/week T90 in secs signal outputs/ inputs Analog output Per measurement: 1 x 4-20mA (standard), 2 x 4-20 mA per transducer optional with addition of extra option board for 2 transducers, 1 x 0-10V (optional) Analog input Digital input Up to 8 digital inputs (2 per transducer) 4 relays as standard (8 with autocal), up to 32 relays,...
Open the catalog to page 3PHYSICAL Size Bench top: With expansion chassis: Rack Mount: With expansion chassis: Main unit: approx 14kg (30.9lb) Expansion chassis: approx 13.7kg (30.2lb) (dependent on number and type of sensors used) OPERATING ENVIRONMENT Operating temperature Storage temperature Ambient pressure range Relative humidity -500m (below sea level) to 2000m (above sea level) Warm-up time Warm up time is typically <20 minutes from cold start at 20oC (68oF), may be longer for the higher sensitivity measurements with heaters UTILITIES Power SAMPLE WETTED MATERIALS PARAMAGNETIC CONTROL 303 stainless steel 316...
Open the catalog to page 4This product complies with the EMC Directive, the Low Voltage Directive, and all other applicable directives. electrical safety Electrical safety to IEC 61010-1, (CSA Electrical Certification pending) Rated for “Overvoltage Category II” and “Pollution Degree 2” Standard chassis with mounting ears Extended chassis with mounting ears Dimensions shown in millim
Open the catalog to page 5OPTIONS ANALZYER Background gas Sample system Standard N2 background O2 background Flow driven Pressure driven Not required 500ml/min (sample) 2,500ml/min (sample) 5,000ml/min (by-pass) Back pressure valve, O2 purity Not required Required w/ standard filter Configurable alarms Two alarms (standard) Four alarms Eight alarms Isolated analog output Digital input Isolated analog input Not required 2 digital Not required Isolated 4-20mA Please tick the box for required MODULE 1 options Not required 500ml/min (sample) 2,500ml/min (sample) 5,000ml/min (by-pass) Back pressure valve, O2 purity Not...
Open the catalog to page 6Not required 500ml/min (sample) 2,500ml/min (sample) 5,000ml/min (by-pass) Not required 500ml/min (sample) 2,500ml/min (sample) 5,000ml/min (by-pass) Back pressure valve, O2 purity Back pressure valve, O2 purity Not required Required w/ standard filter Not required Required w/ standard filter Configurable alarms Two alarms (standard) Four alarms Eight alarms Configurable alarms Two alarms (standard) Four alarms Eight alarms Isolated analog output Isolated analog output Digital input Digital input Isolated analog input Isolated analog input Please tick the box for required MODULE 3 options...
Open the catalog to page 7OPTIONS aquaxact AquaXact 1688 transducer None Required Measurement range Transducer type Not required Sample block, NPT 1/4" Swagelok Sample block, VCO fittings Sample block, VCR fittings Sample system #1 Sample system #2 Sample system #3 Sample system #4 Sample system #5 Transducer cables 5 meter cable digital 10 meter cable digital 100 meter cable digital GENERAL CONFIGURATION Power cord Flow alarm Not required USA Europe UK Not required Fitted to module 1 Fitted to module 2 (coming soon) Serial communications Not required RS232 communication RS485 communication w/Modbus RS232 & RS485...
Open the catalog to page 8WE’RE READY TO HELP WHATEVER YOUR GAS ANALYSIS REQUIREMENTS, WHEREVER YOU ARE These analyzers are not intended for any form of use on humans and are not medical devices as described in the Medical Devices Directive 93/42EEC. Please note: Whilst every effort has been made to ensure accuracy, no responsibility can be accepted for errors and omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards and guidelines. This document is not intended to form the basis of a contract. Servomex has a policy of...
Open the catalog to page 9All SERVOMEX catalogs and technical brochures
-
Servomex Gas Guide - Issue 4
76 Pages
-
Servomex Product Guide - Issue 8
15 Pages
-
Servomex Service Guide - Issue 3
13 Pages
-
Servomex Product Portfolio
2 Pages
-
DF560E Operator Manual
144 Pages
-
SERVOPRO PureGas
4 Pages
-
SERVOPRO NOx
4 Pages
-
SERVOPRO HFID
4 Pages
-
SERVOPRO 4900 Multigas
10 Pages
-
DF-745 Operator Manual
112 Pages
-
ES 39 Sustainability
11 Pages
-
ES 38 Korea Special
19 Pages
-
ES 37 Clean Air part II
11 Pages
-
ES 36 Purity & Specialty
11 Pages
-
ES 35 Photometric Analysis
11 Pages
-
ES 34 70th Anniversary
15 Pages
-
ES30 Air Separation Units
11 Pages
-
ES 29 Clean Air
11 Pages
-
ES 28 Gas Analysis Applications
11 Pages
-
Sensing Technologies
13 Pages
-
DF760E Operator Manual
182 Pages
-
DF750 Operator Manual
112 Pages
-
DF745SGMax Operator Manual
90 Pages
-
DF-740 Operator Manual
87 Pages
-
DF-730 Operator Manual
82 Pages
-
DF560E Operator Manual 082616
146 Pages
-
DF550E Operator Manual 082616
134 Pages
Archived catalogs
-
SERVOTOUGH SpectraScan 2400
2 Pages
-
SERVOTOUGH H2 Scan
2 Pages
-
Servomex Product Portfolio
2 Pages
-
Servomex Service Portfolio
2 Pages
-
Servomex GAS GUIDE issue 3
77 Pages
-
Servomex Service Guide Issue 2
11 Pages
-
Servomex Product Guide Issue 7
13 Pages
-
Servomex Gas Guide 2022
65 Pages