PRODUCT OVERVIEW S E R V O P R O DF-750 NanoTrace ULTRA ULTRA HIGH PURITY FROM OUR GROUND-BREAKING ULTRA SERIES, A LASER MOISTURE ANALYZER FOR SEMICONDUCTOR PROCESSES: LOW 55PPT DETECTION & EASY OPERATION UNRIVALLED PERFORMANCE Uses industry-leading, high stability tunable diode laser (TDL) trace sensing with zero drift Analysis resistant to gas cell contamination: DF-750 ULTRA operates to specification with up to 90% signal loss Industry-leading 55ppt Lower Detection Limit Manufactured by Servomex over 60 years’ experience pioneering gas analysis with thousands of units used in the field SENSING TECHNOLOGY FLEXIBLE Broad detection range: 0-20ppm Storage and recall function: calibration, system error and measurement data facilitates archiving operational history Operable via front panel or digital communication options Bulk gas quality control checks for UHP electronic gases used in 300mm semiconductor fabs Leak detection checks for UHP electronic gases used in 300mm semiconductor fabs Learn more about the DF-750 NanoTrace ULTRA Simplified ongoing maintenance requirements through the use of nondepleting, low drift potential TDL sensing technology High reliability - repeatable baseline measurements are not affected by a loss in mirror reflectivity LOW COST OF OWNERSHIP Robust sensor construction reduces maintenance requirements Absence of zero drift extends calibration intervals BENCHMARK COMPLIANCE IEC 61010-1 Overvoltage Category II, Pollution Degree 2 EU EMC Directive EU Low Voltage Directive
Open the catalog to page 1PRODUCT OVERVIEW S E R V O P R O DF-750 NanoTrace ULTRA HIGH STABILITY TDL TRACE/ULTRA-TRACE MEASUREMENTS ULTRA HIGH PURITY USEFUL LINKS Introducing the Servomex ULTRA range of products, offering unparalelled performance for CQC analysis of UHP gases used in semiconductor wafer fabs. The DF750 ULTRA offers improved performance over its predecessor DF750, with improved signal processing algorithms. Ultra-trace qualification of UHP electronic gases is essential for semiconductor fabrication. You need a moisture analyzer that can deliver high stability measurements with sensitive and...
Open the catalog to page 2TECHNICAL DATA SHEET S E R V O P R O DF-750 NanoTrace ULTRA SPECIFICATIONS Gas measured Tunable Laser Diode (TDL) PERFORMANCE Measurement range Lower detection limit Intrinsic error (accuracy) FS ±3% of reading / ±0.2ppb (whichever is greater) Zero drift/month Span drift/month Smallest recommended output range Upset recovery time <5 minutes to return to within 10ppb of previous stable reading SIGNAL OUTPUTS/inputs Analog output 5 output options available Isolated 4-20mA dc and a choice of 0-1, 0-2, 0-5 or 0-10V dc Analog output range Output parameters Scalable to any range between 0-2ppb to...
Open the catalog to page 3PHYSICAL Size Aspirator vacuum source Aspirator with 1/4” compression inlet and outlet fittings 19” rack mount NEMA 1 enclosure UTILITIES Supply voltage Optional - recommended if operating near LDL Nitrogen or air at 80psig (±3psig) 15l/min with a backpressure on outlet stream of <2psig with 1/4” compression inlet and outlet fittings Pneumatically actuated springless diaphragm valves, orbital butt welded assembly with zero dead volume for sensor isolation and zero verification high capacity moisture dryer provides moisture-free zero gas heated and temperature controlled sample delivery...
Open the catalog to page 4OPTIONS description Pump vacuum source Pump with 1/4” compression inlet and outlet fittings Hydrogen safety system purge Optional safety system for use with hydrogen includes sample delivery interlock and case purge valves for instrument housing, and enclosure and purge protection system for optional external vacuum pump. Hydrogen safety system can be ordered with or without the enclosure and purge protection system for the optional vacuum pump (NOTE: hydrogen safety system limits available relays from 4 to 3) configruation options Power input 110 VAC input power 220 VAC input power...
Open the catalog to page 5WE’RE READY TO HELP WHATEVER YOUR GAS ANALYSIS REQUIREMENTS, WHEREVER YOU ARE These analyzers are not intended for any form of use on humans and are not medical devices as described in the Medical Devices Directive 93/42EEC. Please note: Whilst every effort has been made to ensure accuracy, no responsibility can be accepted for errors and omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards and guidelines. This document is not intended to form the basis of a contract. Servomex has a policy of...
Open the catalog to page 6All SERVOMEX catalogs and technical brochures
-
Servomex Gas Guide - Issue 4
76 Pages
-
Servomex Product Guide - Issue 8
15 Pages
-
Servomex Service Guide - Issue 3
13 Pages
-
Servomex Product Portfolio
2 Pages
-
DF560E Operator Manual
144 Pages
-
SERVOPRO PureGas
4 Pages
-
SERVOPRO NOx
4 Pages
-
SERVOPRO HFID
4 Pages
-
SERVOPRO 4900 Multigas
10 Pages
-
DF-745 Operator Manual
112 Pages
-
ES 39 Sustainability
11 Pages
-
ES 38 Korea Special
19 Pages
-
ES 37 Clean Air part II
11 Pages
-
ES 36 Purity & Specialty
11 Pages
-
ES 35 Photometric Analysis
11 Pages
-
ES 34 70th Anniversary
15 Pages
-
ES30 Air Separation Units
11 Pages
-
ES 29 Clean Air
11 Pages
-
ES 28 Gas Analysis Applications
11 Pages
-
Sensing Technologies
13 Pages
-
DF760E Operator Manual
182 Pages
-
DF750 Operator Manual
112 Pages
-
DF745SGMax Operator Manual
90 Pages
-
DF-740 Operator Manual
87 Pages
-
DF-730 Operator Manual
82 Pages
-
DF560E Operator Manual 082616
146 Pages
-
DF550E Operator Manual 082616
134 Pages
Archived catalogs
-
SERVOTOUGH SpectraScan 2400
2 Pages
-
SERVOTOUGH H2 Scan
2 Pages
-
Servomex Product Portfolio
2 Pages
-
Servomex Service Portfolio
2 Pages
-
Servomex GAS GUIDE issue 3
77 Pages
-
Servomex Service Guide Issue 2
11 Pages
-
Servomex Product Guide Issue 7
13 Pages
-
Servomex Gas Guide 2022
65 Pages