SERVOPRO DF-550E NanoTrace Product Brochure
7Pages

{{requestButtons}}

Catalog excerpts

SERVOPRO DF-550E NanoTrace Product Brochure - 1

PRODUCT OVERVIEW S E R V O P R O DF-550E NanoTrace ULTRA HIGH PURITY ULTRA TRACE OXYGEN ANALYZER OPTIMIZED FOR QUALITY MEASUREMENTS IN HIGH PURITY ELECTRONIC GASES UNRIVALLED PERFORMANCE Uses industry-leading, high stability coulometric sensor, with ultra-low drift GAS OXYGEN EASY TO USE Bench top, panel mount or rack mount options ighly sensitive 200ppt Lower H Detection Level (LDL) Simplified ongoing maintenance requirements Fast speed of response in fluctuating O2 concentrations and flow conditions Optional calibration system for compact integration onto the rear of the panel APPLICATION QUALITY TRACE PPB ULTRA TRACE PPT Quick upset recovery dry- down avoids “running blind” when process problems occur SENSING TECHNOLOGY FLEXIBLE Suitable for use H2, He, CH4, CO, N2, Ar and a host of fluorocarbons and slightly acidic HP gases‡ Optional zero calibration system allows for mobile field use Flexible configuration options: initiation via front panel/digital interconnect KEY APPLICATIONS Quality control checks for electronics grade gases Battery backup optional* Use in 18 different sample gases. Standard with our gas scale factor feature‡ Leak detection for electronics grade gas lines and VMB LOW COST OF OWNERSHIP Long lasting high capacity purifier on optional zero calibration system Non-depleting coulometric sensor with five-year warranty Requires only an annual SPAN calibration and RSA fluid quarterly Expensive and disruptive sensor replacements not required BENCHMARK COMPLIANCE IEC 61010-1 Overvoltage Category II, Pollution Degree 2 EU EMC Directive EU Low Voltage Directive * Not for use with flammable samples ‡ Analyzer for use with flammable samples shall be configured with stainless steel inlet and outlet plumbing only Learn more about the DF-550E NanoTrace Visit servomex.expert

Open the catalog to page 1
SERVOPRO DF-550E NanoTrace Product Brochure - 2

PRODUCT OVERVIEW S E R V O P R O DF-550E NanoTrace HIGH STABILITY COULOMETRIC TRACE MEASUREMENTS When you work in quality control of electronic gases, you need an ultra-trace O2 contaminant detector and/or, a gas line leak detection analyzer. The DF-550E can deliver both with high performance, stable measurements in a light and flexible configuration. You need analysis that is both stable, reliable and ultra-sensitive; it needs to deliver consistent results - untroubled by changing sample and flow rate conditions - and be able to overcome upset events quickly and effectively. Flexibility is...

Open the catalog to page 2
SERVOPRO DF-550E NanoTrace Product Brochure - 3

TECHNICAL DATA SHEET S E R V O P R O DF-550E NanoTrace SPECIFICATIONS Gas measured H2, He, CH4, CO, N2, Ar and a host of fluorocarbons and slightly acidic HP gases‡ Coulometric non-depleting electrochemical sensor PERFORMANCE Measurement range Intrinsic error (accuracy) FS ±3% of reading / 3% of measurement range or ±0.1ppb Zero drift/month Lower detection limit (LDL) Upset recovery time <5 minutes to return to within 10ppb of previous stable reading SIGNAL OUTPUTs/inputs Analog outputs 4 analog and digital output options available; Non-isolated 0-5V dc, 0-1, 0-2, 0-5 or 0-10V dc. Analog...

Open the catalog to page 3
SERVOPRO DF-550E NanoTrace Product Brochure - 4

PHYSICAL Size Benchtop, panel mount or rack mount options Storage temperature Sensor storage conditions We recommend that the analyzer be operated as intended, within 6 months of delivery UTILITIES Supply voltage SAMPLE WETTED MATERIALS ANALYZER FITTED WITH Stainless steel, G10 epoxy and polypropylene This product complies with the EU EMC Directive, the EU Low Voltage Directive, Overvoltage Category II, Pollution Degree 2 and all other applicable directives. electrical safety DIMENSIONAL DRAWINGS Dimensions shown in millimetres [

Open the catalog to page 4
SERVOPRO DF-550E NanoTrace Product Brochure - 5

OPTIONS configruation options Sensor Basic sensor Stab-El sensor Power input 110 VAC input power 220 VAC input power Calibration system Not required Automated calibration system Manual calibration system Auto control of user-cal HIgh capacity purifier Case purge Panel mount Rack mount Bench top Not required RS232 communication RS485 communication Flow alarm Relay contacts Not required One relay contact Two relay contacts Three relay contacts Four relay contacts Stainless steel outlet Downstream isolation valve UHP flow control valve High purity pressure regulator High purity regulator...

Open the catalog to page 5
SERVOPRO DF-550E NanoTrace Product Brochure - 6

OPTIONS configruation options Not required Required Stainless steel tags Tag text - 01 Tag text - 02 Tag text - 03 Electrolyte type Electrolyte shipment method None required, has own stock From factory (add line item) Other Smx plnt (add line item) Please tick the box for required options

Open the catalog to page 6
SERVOPRO DF-550E NanoTrace Product Brochure - 7

WE’RE READY TO HELP WHATEVER YOUR GAS ANALYSIS REQUIREMENTS, WHEREVER YOU ARE These analyzers are not intended for any form of use on humans and are not medical devices as described in the Medical Devices Directive 93/42EEC. Please note: Whilst every effort has been made to ensure accuracy, no responsibility can be accepted for errors and omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards and guidelines. This document is not intended to form the basis of a contract. Servomex has a policy of...

Open the catalog to page 7

All SERVOMEX catalogs and technical brochures

  1. SERVOPRO NOx

    4 Pages

Archived catalogs