1. Catalogs
  2. SERVOMEX
  3. SERVOPRO Chroma Product Brochure

SERVOPRO Chroma Product Brochure

SERVOPRO Chroma Product Brochure

SERVOPRO Chroma Product Brochure

Product catalog summary
Overview: The document provides a comprehensive overview of the SERVOPRO Chroma gas chromatography system, highlighting its key applications, performance features, and technical specifications. It is designed for high-purity gas production and trace gas analysis across various industrial applications.
Key Applications: The Chroma system is utilized in medical gas production, air separation plants, cryogenic truck loading stations, and high-purity gas production. It is a versatile platform suitable for a wide range of applications.
Performance and Technology: The system employs ultra-sensitive and highly selective patented Plasma Emission Detector (PED) technology, offering high reliability and performance. It can measure methane and non-methane hydrocarbons (NMHC) without a Flame Ionization Detector (FID), reducing maintenance needs. The ArgonSep feature allows for argon separation from oxygen without scrubbers.
Flexibility: The Chroma system supports ultra-trace analysis of gases such as H2, Ne, O2, N2, Ar, CH4, CO, CO2, and NMHC in various background gases. It uses Plasma, FID, and Thermal Conductivity Detector (TCD) technologies based on application needs. The compact design fits into a single 4U rack, and it offers flexible communication options including Ethernet, RS232, and 4-20 mA output.
Ease of Use: The system features comprehensive device interaction and monitoring through intelligent software, allowing remote configuration via Ethernet/Internet. It includes an electronic carrier and sample flow PID control system and remote range identification contact per impurity.
Cost Efficiency: The Chroma system offers low ownership costs with simplified reporting functions facilitated by the software. The PED technology eliminates the need for a separate methanizer.
Compliance and Safety: The system complies with Class B digital apparatus requirements of ICES-001 of Canada, Part 15 of the US FCC rules for Class B equipment, and IEC 61010-1 for electrical safety. It is rated for Over Voltage Category II and Pollution Degree 2.
Technical Specifications: The document details the operating environment, including temperature, humidity, and altitude limits. It specifies the performance of PED, TCD, and FID technologies, including limits of detection for various impurities in different background gases. The system's compliance with EC directives and electrical safety standards is also outlined.
Application Configurations: Various configurations are provided for different background gases and applications, detailing minimum and maximum ranges, product variants, and detector types.
Disclaimer: The document notes that the analyzers are not intended for medical use and advises users to consult the latest regulations and standards. Servomex reserves the right to change specifications without notice.
See more

Catalog excerpts

SERVOPRO Chroma Product Brochure-1

Product overview Safe area Highly versatile trace gas analyzer platform configurable to a wide range of applications Unrivalled performance Percent Multiple Trace Ultra Trace Quality Process control SENSING TECHNOLOGY Flame Ionization Detector Thermal Conductivity Uses ultra-sensitive and highly selective patented PED sensing technology, delivering the highest reliability and performance currently available PlasmaHC measures methane and NMHC without the use of a FID, eliminating the need for maintenance and fuel. ArgonSep separates Ar from O2 without the need for scrubbers, providing a sensitive, maintenance-free measurement Flexible Comprehensive solution for ultra-trace H2, Ne, O2, N2, Ar, CH4, CO, CO2 and NMHC in a number of background gases; H2, O2, N2, Ar, He and CO2 Plasma, FID and TCD technologies used depending on application Key applications Medical gas production Air separation plants Cryogenic truck loading station Compact design that fits into a single 4U rack Flexible communication options including Ethernet, RS232 and 4-20 mA output Easy to use Comprehensive device interaction and monitoring via intelligent software Remote configuration via Ethernet/Internet Electronic carrier and sample flow PID control system Remote range I.D. contact per impurity Low cost of ownership Simplified reporting functions facilitated by the software PED sensing technology does not require a separate methanizer Benchmark compliance Class B digital apparatus requirements of ICES-001 of Canada through the application of EN 61000-6-3:2007 Part 15 of the US FCC rules for Class B equipment IEC 61010-1 for electrical safety C “Low Voltage Directive” by E application of EN 61010-1 and rated for Over Voltage Category II, Pollution Degree 2 High purity gas production For more information visit servomex.com/contac

 Open the catalog to page 1
SERVOPRO Chroma Product Brochure-2

Product overview Safe area High versatility for diverse application needs Applications that depend on the very highest levels of product purity depend on trace analysis of exceptional sensitivity and performance. Impurities requiring measurement are both diverse in nature and found in a number of background gas streams, so high flexibility is also a must. Measurements need to be reliable, so a technology that can provide stability is essential. No matter what your application monitoring requirements, you’ll also want a solution that is easy to use and has a low lifetime cost-of-ownership. We...

 Open the catalog to page 2
SERVOPRO Chroma Product Brochure-3

Technical data sheet SERVOPRO Chroma Specifications Plasma Emission Detector (PED), Flame Ionization Detector (FID), Thermal Conductivity Detector (TCD) Technology Performance Plasma Emission Detector (PED) Background gas Min range = 0-1ppm, for all backgrounds except for CO2 where min range = 0-10ppm. Max range is application dependent Flame Ionization Detector (FID) Background gas Min range = 0-1ppm. Max range = 600ppm (impurity and application dependent) Thermal Conductivity Detector (TCD) Background gas Limit of Detection (LOD) Impurities Complies with US or European Pharmacopeia Complies...

 Open the catalog to page 3
SERVOPRO Chroma Product Brochure-4

Signal outputs/inputs Analog output 1 x 4-20 mA output per peak - up to 8 outputs Digital outputs 1 x Remote range identification output per peak - up to 8 2 x Alarm dry contact outputs - user pre-settable limited 1 x System status dry contact output Digital inputs 1 x digital isolated input - remote initiation of analysis Serial comms Remote interaction via RS232 ASCII protocol and ethernet/internet Sample must be oil free, non-corrosive, non-condensing and non-flammable mixtures Sample flow Typically 25-150ml/min (application dependent) Sample pressure Argon or helium (or both) Physical Size...

 Open the catalog to page 4
SERVOPRO Chroma Product Brochure-5

Dimensional drawings Dimensions shown in millimetres (dimensions in square brackets are in inches)

 Open the catalog to page 5
SERVOPRO Chroma Product Brochure-6

Application configurations Form factor Carbon dioxide Product Packages Detector variant Crude argon Industrial gas quality - grade 5 or less MC = master chassis, SC = secondary chassis, PC = stand-alone computer For higher ranges, or other applications, please contact Servomex

 Open the catalog to page 6
SERVOPRO Chroma Product Brochure-7

Application configurations Background gas Industrial gas quality - grade 5N or better Product variant Form factor Carbon dioxide Nitrous oxide Medical gases MC = master chassis, SC = secondary chassis, PC = stand-alone computer For higher ranges, or other applications, please contact Servomex

 Open the catalog to page 7
SERVOPRO Chroma Product Brochure-8

We’re ready to help Whatever your gas analysis requirements, wherever you are. These analyzers are not intended for any form of use on humans and are not medical devices as described in the Medical Devices legislation or regulation. Please note: Whilst every effort has been made to ensure accuracy, no responsibility can be accepted for errors and omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards and guidelines. This document is not intended to form the basis of a contract. Servomex has a policy...

 Open the catalog to page 8

All SERVOMEX catalogs and technical brochures

  1. ES 29 Clean Air

    11  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.