Product catalog summary
Introduction
The document is an operator manual for the SERVOFLEX MiniHD 5200, a portable gas analyser by Servomex. It provides detailed instructions for installation, operation, and maintenance.
Description and Definitions
  • Scope: Covers installation, operation, and maintenance instructions.
  • Safety Information: Highlights the importance of understanding the manual and includes warnings about potential hazards.
  • Description: Designed for field and laboratory analysis, measuring oxygen, carbon dioxide, and carbon monoxide using paramagnetic and infrared transducers.
  • Product Options: Includes internal sample pump, gas probe accessory, sample conditioning kit, and protective cases.
Specifications
  • General: Dimensions are 160 x 140 x 185 mm, with a mass of 1.8 to 2.3 kg. Power supply: 100 to 240 V a.c., 47 to 63 Hz.
  • Environmental Limits: Operating temperature: -10 to +50 °C, storage temperature: -20 to +60 °C, battery charging temperature: +10 to +40 °C.
Unpacking and Setup
Instructions for safely unpacking and setting up the analyser, including battery charging and security settings.
User Interface
Details on the interface, including start-up screens, soft keys, status icon bar, and menu options.
General Operation
Instructions for locating, calibrating, and using the analyser, including data logging and display adjustments.
Routine Maintenance
Tasks include cleaning, inspecting the inlet filter, and replacing the battery pack.
Fault Finding
Procedures for identifying and resolving faults, including viewing fault messages.
Storage and Disposal
Guidelines for storing and disposing of the analyser according to regulations.
Spares
Information on available spare parts for the analyser.
Appendices
Includes conversion factors, optional accessories, and compliance with standards.
Calibration and Sample Gases
Calibration gases must be handled with care, and the analyser should not be used with flammable gases. Specific inlet pressures are required for calibration and sample gases.
Performance
Industrial Oxygen Sensor: Measures 0 to 100% oxygen with a resolution of 0.1% and accuracy of ± 0.1% oxygen. High Accuracy Oxygen Sensor: Offers a resolution of 0.01% oxygen and accuracy of ± 0.05% oxygen. IR Sensors: Measure gases like carbon monoxide, carbon dioxide, or methane with a resolution less than 0.1% of the full scale range.
Battery
Uses a lithium-ion battery with a recharge time of 4 to 8 hours and an operating life of 8 to 24 hours.
Password Protection and Menu Structure
Details on password protection levels and menu navigation for data logging, settings, calibration, alarms, and fault viewing.
Power Save Mode and Pump Operation
The analyser features a power save mode and options for manual or timed pump operation.
Calibration and Sample Readings
Calibration is necessary before initial use and after moving the analyser. Sample readings should be taken in the same orientation as during calibration.
Display Units and Measurement Alarms
Procedures for selecting display units and configuring measurement alarms.
Data Logging and Display Adjustments
The analyser can store up to 200 measurements, and users can adjust the screen's backlight timer and contrast.
Routine Maintenance and Leak Testing
Regular cleaning and leak testing are advised, with specific instructions for battery replacement and preventative maintenance.
Fault Finding and Troubleshooting
Steps for troubleshooting common issues, including power supply and display problems.
Storage and Disposal
Guidelines for storing the analyser and disposing of it according to local regulations.
Spares and Maintenance
Only use specified spares to avoid damage, and maintain a stock of essential parts.
Compliance and Standards
The analyser complies with various directives and standards, including the Electromagnetic Compatibility Directive and IEC 61010-1:2001.
See more

Catalog excerpts

SERVOFLEX MiniHD 5200 Operator Manual 05210001a_5-1

OPERATOR MANUAL Part Number: Revision: Language:

 Open the catalog to page 1
SERVOFLEX MiniHD 5200 Operator Manual 05210001a_5-2

SERVOMEX - SPECIALISTS IN GAS ANALYSIS Thank you for purchasing this Servomex product. Servomex has been specialising in the field of gas analysis for over half a century and our products have an excellent reputation for reliability and longevity. When you require high performance gas analysis technology, Servomex is a market leader in terms of experience and knowledge. Servomex supports all users of its products through a strong network of support teams. We are able to provide a wide range of services including commissioning, routine maintenance and troubleshooting. You can also call on one...

 Open the catalog to page 2
SERVOFLEX MiniHD 5200 Operator Manual 05210001a_5-4

This page intentionally blank.

 Open the catalog to page 4
SERVOFLEX MiniHD 5200 Operator Manual 05210001a_5-5

LIST OF CONTENTS Section Scope of this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Safety information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sample measurement configurations . . . . . . . . . . . . . . . . . . . . . . . Other product options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Environmental limits...

 Open the catalog to page 5
SERVOFLEX MiniHD 5200 Operator Manual 05210001a_5-6

CONTENTS (CONTINUED) Section Locating the analyser and switching on . . . . . . . . . . . . . . . . . . . . . Calibrating the analyser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Taking sample readings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Correcting oxygen measurement for different background gases . Overview of measurement errors (oxygen only) . . . . . . . . . . . . . . Entering a cross-interference compensation (oxygen only). . . . . . Selecting display units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuring the...

 Open the catalog to page 6
SERVOFLEX MiniHD 5200 Operator Manual 05210001a_5-7

CONTENTS (CONTINUED) Section DISPLAY UNIT CONVERSION FACTORS . . . . . . . . . . . . . . . . . . 65 OPTIONAL GAS PROBE ACCESSORY . . . . . . . . . . . . . . . . . . . . 66 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Preparing for use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Using the probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Additional maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Additional spares . . . . . . . . . . . ....

 Open the catalog to page 7
SERVOFLEX MiniHD 5200 Operator Manual 05210001a_5-8

This page intentionally blank.

 Open the catalog to page 8
SERVOFLEX MiniHD 5200 Operator Manual 05210001a_5-9

Scope of this manual This manual provides installation, operation and routine maintenance instructions for the Servomex 5200 HD Portable Gas Analyser, abbreviated to "analyser" in the remainder of this manual. Safety information Read this manual and ensure that you fully understand its content before you attempt to install, use or maintain the analyser. Important safety information is highlighted in this manual as WARNINGs and CAUTIONs, which are used as follows: WARNING Warnings highlight specific hazards which, if not taken into account, may result in personal injury or death. CAUTION Cautions...

 Open the catalog to page 9
SERVOFLEX MiniHD 5200 Operator Manual 05210001a_5-10

The analyser uses a paramagnetic transducer to determine the oxygen content of gas samples, or uses an infrared transducer to determine the carbon dioxide (CO2) or carbon monoxide (CO) content of gas samples. Gas sample measurements are shown on the analyser display (see Section 4.2). The analyser is supplied with an internal rechargeable battery, and with a power supply unit. The analyser is simple to operate, with an intuitive user interface (see Section 4). The analyser requires little routine maintenance (see Section 7), other than calibration (which is essential for the accuracy of sample...

 Open the catalog to page 10
SERVOFLEX MiniHD 5200 Operator Manual 05210001a_5-11

Soft key 1 Soft key 2 Soft key 3 Soft key 4 Sample gas label * Display Power On/Off key Fault LED (amber) Alarm LED (red) Sample pump LED (green) Sample pump key † * The legend on the label shows the sample gas for which the analyser is configured. † Only active if the analyser has an optional internal sample pump.

 Open the catalog to page 11
SERVOFLEX MiniHD 5200 Operator Manual 05210001a_5-12

Description Filter retaining cap Breather vent Rechargeable battery cover Figure 2 - Bottom of the analyser

 Open the catalog to page 12
SERVOFLEX MiniHD 5200 Operator Manual 05210001a_5-13

Description Sample gas inlet Sample gas outlet Description Bypass gas outlet DC power inlet Figure 3 - Back of the analyser

 Open the catalog to page 13
SERVOFLEX MiniHD 5200 Operator Manual 05210001a_5-14

SPECIFICATION WARNING You must install and use the analyser in accordance with the requirements of this section and subsequent sections of the manual. If you do not, the protection facilities incorporated into the design of the analyser may not operate as intended, sample gas measurements may not be accurate, or the analyser may be damaged. General Dimensions (width x depth x height) Mass (minimum to maximum) Electrical supply requirements Power supply unit Analyser * As supplied by the power supply unit (through a centre pin +ve connector). 2.2 Environmental limits Ambient temperature range...

 Open the catalog to page 14
SERVOFLEX MiniHD 5200 Operator Manual 05210001a_5-15

Calibration gases WARNING If the analyser is specified for use with carbon monoxide or carbon dioxide, the concentrations of the gases used may be above their respective threshold limit values, and should therefore be considered toxic. You must therefore carry out a risk assessment before you use the analyser with such gases. The maximum inlet pressures of such gases are: • For an analyser with an internal sample pump: 8.9 kPa gauge (0.089 bar gauge, 1.3 psi gauge). • For an analyser with an AFCD: 35 kPa gauge (0.35 bar gauge, 5 psi gauge). WARNING The calibration gas must not contain or be contaminated...

 Open the catalog to page 15
SERVOFLEX MiniHD 5200 Operator Manual 05210001a_5-16

Sample gases WARNING The analyser must not be used with flammable sample gases. You must therefore carry out a risk assessment before you use the analyser, to ensure that the gases you will sample are not flammable. WARNING If the analyser is specified for use with carbon monoxide or carbon dioxide, the concentrations of the gases used may be above their respective threshold limit values, and should therefore be considered toxic. You must therefore carry out a risk assessment before you use the analyser with such gases. The maximum inlet pressures of such gases are: • For an analyser with an...

 Open the catalog to page 16

All SERVOMEX catalogs and technical brochures

  1. ES 29 Clean Air

    11  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.