OxyDetect Product Brochure
6Pages

{{requestButtons}}

Catalog excerpts

OxyDetect Product Brochure - 1

PRODUCT OVERVIEW G A S D E T E C T I O N OxyDetect SAFE & HAZARDOUS AREAS NON-DEPLETING PARAMAGNETIC O2 AREA MONITOR DESIGNED FOR OPERATOR PROTECTION APPLICATIONS LOW COST OF OWNERSHIP UNRIVALLED PERFORMANCE Innovative oxygen depletion detection from the industry leader in paramagnetic sensing technology Uses advanced microprocessor-based diagnostics that are safe, reliable and easy to access SENSING TECHNOLOGY Output range of 0-25% O2 3 x SPCO relays, Alarm 1, Alarm 2, Fault Pharmaceutical plants Semiconductor facilities Laboratories and universities Non-depleting paramagnetic design delivers long life sensor without measurement deterioration Eliminates costs associated with regular replacement of electrochemical cells Exceptional measurement stability eliminates need for frequent calibration Not affected by sterile area cleaning agents Suitable for indoor use for temperatures ranging from +41°F to +113°F (+5°C to +45°C) Light wall-mountable design for easy installation Helium production and storage Easy to use digital interface Fault alarm via mA jam to 0mA and SPCO relay Simple integration via isolated 4-20mA output with linear measurement Industrial gas plants and storage Air separation units (ASU’s) Enclosed areas: refineries; hydrocarbon processing; chemicals Learn more about the SERVOMEX OxyDetect Visit servomex.expert/pb-od BENCHMARK COMPLIANCE SIL2 hardware compliance Hazardous Area ATEX Cat. 3, IECEx Zone 2, North American Class 1, Div

Open the catalog to page 1
OxyDetect Product Brochure - 2

PRODUCT OVERVIEW SAFE SAFE & HAZARDOUS AREAS G A S D E T E C T I O N OxyDetect & HAZARDOUS AREA A BREAKTHROUGH IN AREA MONITORING A general purpose/safe area (O2) detector that accurately monitors oxygen levels without the sensor deterioration that affects traditional electrochemical sensors used in competitor detectors. Designed for use in operator protection applications, the OxyDetect utilizes the Hummingbird Paracube® Modus Paramagnetic sensor, whose industryleading levels of linearity, accuracy and reliability have ensured its use as a trusted O2 sensor for the OEM medical market. The...

Open the catalog to page 2
OxyDetect Product Brochure - 3

TECHNICAL DATA SHEET G X X X X X X C T I O N OxyDetect X A S D E T E OxyDetect SPECIFICATIONS gas measured GENERAL PURPOSE LOCATIONS HAZARDOUS AREA LOCATIONS Accuracy (intrinsic error) Zero drift Zero temp coefficient Ambient pressure effects <0.04 reading per 1% change amibent pressure signal outputs/inputs Analog outputs Isolated 4-20mA, user selectable over measurement range Relay outputs 3 x SPCO contacts: 250Vac, 3A or 28Vdc, 1A Alarm 1, Alarm 2, Fault Ethernet output Diagnostics and measurement data, standard RJ45 connector Modbus TCP PHYSICAL Size SAMPLE CONDITIONS Sample gas Sample...

Open the catalog to page 3
OxyDetect Product Brochure - 4

UTILITIES Power Calibration gas Requirements Calibration gas flow rate High calibration set-point Supplied via the calibration cap     21 ± 0.5% O2 Balance N2 (synthetic air) Optional - amibent air by diffusion   20.9% O2 0% O2 (zero grade nitrogen recommended) Validation check gas (optional) Minimum difference between low calibration and high calibration points OPTIONS description Detector type Safe area ATEX Cat 3 / IECEx Zone 2 N. American CL 1 DIV 2 Digital communications None Modbus TCP (Ethernet) User manual Functional safety manual COMPLIANCE hazardous area approvals ATEX North...

Open the catalog to page 4
OxyDetect Product Brochure - 5

DIMENSIONAL DRAWINGS Dimensions shown in millimetres

Open the catalog to page 5
OxyDetect Product Brochure - 6

WE’RE READY TO HELP WHATEVER YOUR GAS ANALYSIS REQUIREMENTS, WHEREVER YOU ARE These analyzers are not intended for any form of use on humans and are not medical devices as described in the Medical Devices Directive 93/42EEC. Please note: Whilst every effort has been made to ensure accuracy, no responsibility can be accepted for errors and omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards and guidelines. This document is not intended to form the basis of a contract. Servomex has a policy of...

Open the catalog to page 6

All SERVOMEX catalogs and technical brochures

Archived catalogs