P 8000 T TA

P 8000 T TA

P 8000 T TA

Product catalog summary
Installation and Safety Instructions
Before installing or connecting the Ozone Generator P8000 TTA, it is crucial to read the manual thoroughly. The generator should not be handled or opened while connected to the mains due to the risk of electric shock. It should not be used in environments exceeding 50°C and must be protected from moisture and corrosive environments. Electrical connections must be performed by qualified personnel, ensuring the installation includes a ground shunt and differential switch. The generator should not be tampered with while connected, and any defects in the power cable should be addressed immediately by technical service. The equipment must be installed in a clean, dry place, and ozone treatment should not occur in the presence of people or animals. Flammable products should not be stored near the equipment.

Technical Characteristics
The generator operates on a 230 V 50 Hz power supply, consuming 0.9 A. It measures 480x250x280 mm and weighs 7 kg, with a maximum ozone production of 8000 mg/h. It features a stainless steel case and a turbine with a 460 m³/h output.

General Description
The P8000 TTA is a portable ozone generator designed for environmental treatments, featuring a robust stainless-steel case and a powerful turbine. It is suitable for applications requiring a mobile generator with high production capacity, achieving cleaning and deodorization through ozone's high oxidation capacity.

Equipment Installation
The generator should be installed in a dry, ventilated area to prevent moisture and dirt from affecting performance. If used in a wet or dirty environment, it should be installed in a suitable room with ozone conducted via a resistant conduit. The conduit should not exceed 7-8 meters to ensure proper ozone flow. The generator should be connected to the mains and operated with a switch on the back. External timers controlling power supply can be used, but voltage regulators should not.

Applications
  • Shock Treatments: The room should be closed, and ozone conducted via a tube. After treatment, wait 20-30 minutes before entering.
  • Air Conditioning Ducts: Install the generator near the duct, ensuring it operates only with air flow.
  • Cold Rooms: Install near the chamber, injecting ozone through a hole. Use distribution tubes for large chambers.
  • Clean Rooms and Laboratories: High ozone concentration is needed for shock treatment, ensuring no presence of people or animals.
  • Odor Removal in Air Extraction Systems: Ozone is injected into exhaust chimneys to enhance oxidation effects.
See more

Catalog excerpts

P 8000 T TA-1

Ozone Generator Installation and use instructions

 Open the catalog to page 1
P 8000 T TA-2

Read this manual before installing or connecting the generator Caution: Do not handle or open the generator while connected to the mains. Risk of download Do not use in environments where the temperature may exceed 50°C Protect from the elements and preserve it from humid and/or corrosive environments Safety Instructions Read this manual completely before installing your computer. Electrical connections must be made by qualified personnel and following current regulations. Make sure that the electrical installation of the equipment has a ground shunt and differential switch according to current...

 Open the catalog to page 2
P 8000 T TA-3

General description The portable Ozone Generator model P8000TTA built in a robust stainless-steel case, is a direct discharge generator for environmental treatments or in ducts, both ventilation as air expulsion. The Generator incorporates a powerful turbine that takes the air from the environment in which it is installed and, previously passing through the particulate filter installed in the rear, propelling it outwards through the Ozone generating valve. The ozonated air is expelled into the environment through the standardized ventilation outlet, with a diameter of 100 mm, which is made of...

 Open the catalog to page 3
P 8000 T TA-4

Aplication The ozone generator model P8000TTA has, among others, the following applications: Shock treatments Completely close the room to be treated and, with the generator located outside, carry the air with ozone conducted by a tube (corrugated, galvanized, pvc ...) to the room to be treated. If the generator is placed in the same treatment room, the ozone will circulate inside the equipment, which being an oxidizing component, will reduce the useful life of the team. Once the application time has elapsed, be careful to wait between 20-30 minutes before entering the room so that residual ozone...

 Open the catalog to page 4
P 8000 T TA-5

Odor removal in air extraction systems In extractor hoods, ozone is injected into the exhaust chimney so that the ozone can perform its effect during the entire time that the air is expelled circulates through the chimney. In these cases, the longer the chimney, the greater the the oxidation effect of the substances that generate bad odors and their effectiveness, since ozone performs its function during the time it is in contact with the exhaust fumes. By means of a tube, the generator outlet is connected to the smoke outlet duct , through a T the size of the outlet tube with reduction to 100...

 Open the catalog to page 5

All SERVI OZONO catalogs and technical brochures

  1. GO 16000 AC

    5  Pages

  2. GO 8000 AC

    5  Pages

  3. GO 4000 AC XL

    5  Pages

  4. GO 24000 TA

    8  Pages

  5. GO 24000 T

    8  Pages

  6. GO 16000 TA

    5  Pages

  7. GO 16000 T

    5  Pages

  8. GO 12000 TA

    5  Pages

  9. GO 8000 TA

    5  Pages

  10. GO 8000 T

    5  Pages

  11. GO 4000 TA

    5  Pages

  12. GO 4000 T

    5  Pages

  13. P ECO 4000 V

    6  Pages

  14. GO 4000 AC CP

    8  Pages

  15. GO 2000 AC SC

    8  Pages

  16. GO 2000 AC

    7  Pages

  17. GO 500 AC TC

    5  Pages

  18. P 500 AC TA

    5  Pages

  19. P 1000 V TA

    6  Pages

  20. P 500 V TA

    6  Pages

  21. GO 2000 V TC

    6  Pages

  22. P 16000 T TA

    6  Pages

  23. TOP-OZO-CAR

    1  Page

  24. TOP-OZO-HOME

    1  Page

  25. GO 1000 V TC

    6  Pages

  26. P 500 AC TC

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.