GO 4000 TA

GO 4000 TA

GO 4000 TA

Product catalog summary
Introduction
This document provides detailed instructions for the installation, use, and maintenance of the GO-4000-TA Ozone Generator. It is crucial to read the manual thoroughly before installation and operation to ensure safety and optimal performance.

Specifications
  • Power Supply: 230 V, 50 Hz
  • Consumption: 120W
  • Dimensions: 65x45x25 mm
  • Ozone Production: 4000 mg/h max
  • Regulation: Digital timer
  • Output: Turbine 460 m³/h

Installation
The generator comes with fixing brackets for easy installation. These brackets should be repositioned after unpacking for proper installation. Ensure that air intakes are not blocked to prevent damage. The generator should be installed in a clean room with dry air for optimal ozone production. It can be mounted horizontally or vertically using the provided fixing blocks.

Operation
Connect the generator to a 230V power source with grounding. The operation is regulated by a digital cyclic timer with a 10-minute cycle, allowing adjustment of active and inactive periods. External timers can also be used for specific scheduling needs.

Applications
  • Air Conditioning Ducts: Install near the duct to inject ozonized air, ensuring operation only when the air circuit is active.
  • Cold Rooms: Install outside the chamber and inject ozone through a duct. For large areas, use a distribution tube for even ozone distribution.
  • Shock Treatments: Conduct treatments with the generator outside the room, ensuring no entry for 20-30 minutes post-treatment.
  • Odor Removal: Inject ozone into exhaust chimneys for effective odor control.
  • Sterilization: Use high ozone concentrations for clean rooms and laboratories, ensuring no human or animal presence during treatment.

Safety and Maintenance
Do not handle or open the generator while connected to the mains. Ensure the generator is not used in environments exceeding 50°C or in humid/corrosive conditions. Maintenance and repairs should be conducted by authorized personnel only. The generator must be equipped with a ground shunt for safety.

Warnings
  • Do not install inside refrigeration chambers.
  • Avoid exposure of people or animals to high ozone concentrations during shock treatments.
  • Ensure the power supply does not exceed 230 V + 10% to prevent malfunction.
See more

Catalog excerpts

GO 4000 TA-2

Ozone Generator GO-4000 TA Turbine The GO-4000-TA can be used both horizontally (on a flat surface) and vertically (wall mounting). For this, the fixing blocks located at the front and back of the generator are used. The distribution of the fixing holes has the following measurements: 570 x 354 mm Read this manual carefully before installing and/or connecting the generator Caution: Do not handle or open the generator while connected to the mains. Risk of download Do not use in environments where the temperature may exceed 50°C Protect from the elements and preserve it from humid and/or corrosive...

 Open the catalog to page 2
GO 4000 TA-3

This Ozone Generator is suitable for, among others, the following applications: Connect the generator to the 230V grid using a plug equipped with grounding. Flip the start-up switch and the equipment will start working. The regulation of the production is carried out by time, by means of a digital cyclic timer, with a cycle of 10 minutes, being able to regulate the operating time and the time of unemployment within that cycle, which will be repeated indefinitely. Using the selector, we vary the number of minutes that the generator will remain active in that 10-minute cycle leaving the rest of...

 Open the catalog to page 3
GO 4000 TA-4

TECHNICAL CHARACTERISTICS Odor removal in air extraction systems In extractor hoods, ozone is injected into the exhaust chimney so that the ozone can perform its effect throughout the time that the expelled air circulates through the chimney. In these cases, the longer the chimney, the greater the oxidation effect of the substances that generate bad odors. Ozon or Characteristics Power supply Consumption Dimensions Production Regulation Output 230 V 50 Hz 120W 65X45X25mm 4000 mg/h max Digital timer Turbine 460 m3/h All the features listed above may be modified without prior notice. Sterilization...

 Open the catalog to page 4

All SERVI OZONO catalogs and technical brochures

  1. GO 16000 AC

    5  Pages

  2. GO 8000 AC

    5  Pages

  3. GO 4000 AC XL

    5  Pages

  4. GO 24000 TA

    8  Pages

  5. GO 24000 T

    8  Pages

  6. GO 16000 TA

    5  Pages

  7. GO 16000 T

    5  Pages

  8. GO 12000 TA

    5  Pages

  9. GO 8000 TA

    5  Pages

  10. GO 8000 T

    5  Pages

  11. GO 4000 T

    5  Pages

  12. P ECO 4000 V

    6  Pages

  13. GO 4000 AC CP

    8  Pages

  14. GO 2000 AC SC

    8  Pages

  15. GO 2000 AC

    7  Pages

  16. GO 500 AC TC

    5  Pages

  17. P 500 AC TA

    5  Pages

  18. P 1000 V TA

    6  Pages

  19. P 500 V TA

    6  Pages

  20. GO 2000 V TC

    6  Pages

  21. P 16000 T TA

    6  Pages

  22. TOP-OZO-CAR

    1  Page

  23. TOP-OZO-HOME

    1  Page

  24. GO 1000 V TC

    6  Pages

  25. P 8000 T TA

    6  Pages

  26. P 500 AC TC

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.