The document provides detailed instructions for the use and installation of the GO-2000-AC SC ozone generator, emphasizing the importance of reading the manual thoroughly before installation.

Precautions
- Do not manipulate or open the generator while connected to electricity.
- Avoid using in environments exceeding 50°C or in damp/corrosive conditions.

Security Instructions
- Installation must be performed by qualified personnel following current regulations.
- Ensure proper grounding and use of a differential switch.
- Do not use if electrical defects are observed.
- Avoid inhaling ozone gas and using flammable products near the equipment.
- Use only ozone-resistant materials for connections.

Technical Characteristics
- Power Supply: 230 V 50Hz
- Consumption: 60 W
- Dimensions: 490 x 303 x 145 mm
- Weight: 5 kg
- Production: 2,000 mg/h max.
- Features: Digital Timer, Fusible 2 A, Stainless Steel Box

General Description
The GO-2000 C model is designed for disinfection and deodorization, suitable for ventilation ducts, cold rooms, and water treatment. It includes a stainless-steel box, ozone reactor, diaphragm compressor, and a digital timer for regulation.

Installation and Operation
- Install in a dry, ventilated place to avoid performance issues.
- Use ozone-resistant tubes for connections, not exceeding 3-4 meters in length.
- Can be mounted on a wall or desktop, ensuring solid surfaces to prevent vibration.
- Connect the network cable and use the digital timer for operation.

Functioning
- The digital timer regulates ozone production with a rotary switch and LED indicators.
- The compressor operates slightly longer than ozone production to clear residual ozone.

Applications
- Air Conditioning/Ventilation Ducts: Install near ducts, ensuring operation with the ventilation circuit.
- Cold Rooms: Install outside, using a tube to inject ozone inside.
- Water Deposits: Use bubblers or a venturi injector for ozone diffusion.
- Odour Elimination: Inject ozone into air extraction ducts for maximum effect.
See more

Catalog excerpts

GO 2000 AC SC-1

Ozono Ozone generator Use and installation instructions

 Open the catalog to page 1
GO 2000 AC SC-2

Please read this manual carefully before installing and/or connecting the generator Precaution: Do not manipulate or open the generator while it is connected to the electrical Do not use in environments where the temperature may exceed 50°C Protect it from the outdoors and preserve it from damp and/or corrosive environments Security instructions Read this manual completely before installing the equipment. The electrical connections must be carried out by qualified personnel and in accordance with current regulations. Make sure that the electrical installation of the equipment and accessories...

 Open the catalog to page 2
GO 2000 AC SC-3

General Description The GO-2000 C model is an Ozone Generator for disinfection and deodorization applications in which it is required to carry the ozone conducted through a small section tube, such as injection in ventilation ducts, treatment of cold rooms, treatment of water by diffusion by bubbling or by means of a venturi injector in recirculation circuits. This ozone generator is mounted in a stainless-steel box, including ozone producing reactor, diaphragm (membrane) compressor, compressor inlet air desiccant cartridge and forced cooling by means of a fan. The regulation system of the equipment...

 Open the catalog to page 3
GO 2000 AC SC-4

Fixing the equipment on a surface can be done in two ways: 1. Through the fixing holes on the base plate (lower) of the equipment, which can be used to place it on fixed spikes on the wall or with screws/fixing plugs. For the latter, I was able to remove the fixing screws from the cover and remove it completely, in order to fix the equipment to the wall from the inside (this last operation should only be carried out by personnel authorized by the manufacturer and always following the safety regulations). 2. Using the fixing brackets (4 units) provided with the equipment. These brackets must be...

 Open the catalog to page 4
GO 2000 AC SC-5

Functioning Once the installation is done, you can start the operation of the equipment, connecting it to the electrical network and activating the switch located on the lower front part (above the network cable). The regulation of this generator is carried out by means of a digital timer located in the front of the equipment, selecting the programming by means of the rotary switch with nine positions and whose operating cycles are indicated by the leds Blue (power supply) and Red (generating ozone). The blue led stays on as long as the equipment is connected, while the red led will only turn...

 Open the catalog to page 5
GO 2000 AC SC-6

The timer regulates the production of the equipment through the operating time. Using the rotary knob we select a position (from 0 to 9). With an operating cycle of 10 minutes, the activation time is regulated as indicated in the following table. Timetable Program N ON timer OFF timer Regulation The equipment will generate air with ozone and expel it through the output connector while the ON time lasts. Once this has elapsed, the generator will remain stopped (OFF time) until the programmed time has elapsed, at which time the timer will start up again, repeating the cycle indefinitely according...

 Open the catalog to page 6
GO 2000 AC SC-7

Water deposits Install porous bubblers in the base from the tank and carry the ozone through a conduit to these diffusers that will be responsible for diffusing the ozonated air in the water, creating a column of bubbles. Another option is a recirculation system with a venturi injector for a correct ozone/water mixture. This system requires a recirculation pump and provides greater diffusion of ozone in the water. Elimination of odours in air extraction systems In air extraction ducts, ozone is injected into the duct, trying to maintain the maximum distance to the outlet, so that the ozone can...

 Open the catalog to page 7

All SERVI OZONO catalogs and technical brochures

  1. GO 16000 AC

    5  Pages

  2. GO 8000 AC

    5  Pages

  3. GO 4000 AC XL

    5  Pages

  4. GO 24000 TA

    8  Pages

  5. GO 24000 T

    8  Pages

  6. GO 16000 TA

    5  Pages

  7. GO 16000 T

    5  Pages

  8. GO 12000 TA

    5  Pages

  9. GO 8000 TA

    5  Pages

  10. GO 8000 T

    5  Pages

  11. GO 4000 TA

    5  Pages

  12. GO 4000 T

    5  Pages

  13. P ECO 4000 V

    6  Pages

  14. GO 4000 AC CP

    8  Pages

  15. GO 2000 AC

    7  Pages

  16. GO 500 AC TC

    5  Pages

  17. P 500 AC TA

    5  Pages

  18. P 1000 V TA

    6  Pages

  19. P 500 V TA

    6  Pages

  20. GO 2000 V TC

    6  Pages

  21. P 16000 T TA

    6  Pages

  22. TOP-OZO-CAR

    1  Page

  23. TOP-OZO-HOME

    1  Page

  24. GO 1000 V TC

    6  Pages

  25. P 8000 T TA

    6  Pages

  26. P 500 AC TC

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.