GO 12000 TA

GO 12000 TA

GO 12000 TA

Product catalog summary
Installation Instructions
Before installing or connecting the GO 12000 TA Ozone Generator, read the manual carefully. Ensure the generator is not connected to the mains when handling or opening it to avoid electrical hazards. The generator should not be used in environments exceeding 50°C and must be protected from moisture and corrosive conditions.

Fixing Brackets
The fixing brackets are initially placed inwards for transport. After unpacking, release, turn over, and reattach the brackets for proper installation.

Air Intake and Ozone Output
The generator features a power switch, fuse holder, and network cable on the front. Ensure air intakes are not blocked to prevent damage. The generator should be placed in a clean room with dry air for optimal ozone production. A duct outlet at the back (100 mm diameter) directs ozone to the application area.

Usage Instructions
Connect the generator to a 230V grounded outlet. Use the digital cyclic timer to regulate ozone production, with a 10-minute cycle adjustable for active and inactive periods. The program selector allows setting the active time from 30 seconds to 9 minutes.

Applications
The generator is suitable for air conditioning ducts, cold rooms, and shock treatments. It should be installed close to ducts or chambers, ensuring operation only when air flow is present. For shock treatments, ensure no people or animals are present, and wait 20-30 minutes before re-entering the treated area.

Technical Characteristics
Power supply: 230 V, 50 Hz
Consumption: 180 W
Dimensions: 645x405x248 mm
Production: 12,000 mg/h max
Output: Turbine
Ensure the generator is equipped with a ground shunt and is maintained by authorized personnel. Avoid using the generator if the power cord is damaged or if voltage exceeds 230 V + 10%.
See more

Catalog excerpts

GO 12000 TA-2

Ozone Generator GO-12000 TA Turbine The GO-12000-TA can be used both horizontally (on a flat surface) and vertically (wall mounting).For this, the fixing brackets located at the front and back of the generator are used. The distribution of fixing holes has the following measures: 570 x 354 mm Read this manual carefully before installing and/or connecting the generator Caution: Do not handle or open the generator while connected to the mains. Risk of download Do not use in environments where the temperature may exceed 50°C Protect from the elements and preserve it from humid and/or corrosive environments...

 Open the catalog to page 2
GO 12000 TA-3

This Ozone Generator is suitable for, among others, the following applications: Connect the generator to the 230V grid using a plug equipped with grounding. Flip the start-up switch and the equipment will start working. The regulation of the production is carried out by time, by means of a digital cyclic timer, with a cycle of 10 minutes, being able to regulate the operating time and the stoppage time within that cycle, which will be repeated indefinitely. Using the selector, we vary the number of minutes that the generator will remain active in that 10-minute cycle, leaving the rest of the time...

 Open the catalog to page 3
GO 12000 TA-4

CHARACTERISTICS TECHNIQUES Odor removal in air extraction systems In extractor hoods, ozone is injected into the exhaust chimney so that the ozone dog performs its effect during the entire time that the expelled air circulates through the chimney. In these cases, the longer the chimney, the greater the oxidation effect of the substances that generate bad odors. Power supply Consumption Dimensions Production Elec protection Output All the features listed above may be modified without prior notice. Do not open without first disconnecting it from the electrical network and not handling it by unauthorized...

 Open the catalog to page 4

All SERVI OZONO catalogs and technical brochures

  1. GO 16000 AC

    5  Pages

  2. GO 8000 AC

    5  Pages

  3. GO 4000 AC XL

    5  Pages

  4. GO 24000 TA

    8  Pages

  5. GO 24000 T

    8  Pages

  6. GO 16000 TA

    5  Pages

  7. GO 16000 T

    5  Pages

  8. GO 8000 TA

    5  Pages

  9. GO 8000 T

    5  Pages

  10. GO 4000 TA

    5  Pages

  11. GO 4000 T

    5  Pages

  12. P ECO 4000 V

    6  Pages

  13. GO 4000 AC CP

    8  Pages

  14. GO 2000 AC SC

    8  Pages

  15. GO 2000 AC

    7  Pages

  16. GO 500 AC TC

    5  Pages

  17. P 500 AC TA

    5  Pages

  18. P 1000 V TA

    6  Pages

  19. P 500 V TA

    6  Pages

  20. GO 2000 V TC

    6  Pages

  21. P 16000 T TA

    6  Pages

  22. TOP-OZO-CAR

    1  Page

  23. TOP-OZO-HOME

    1  Page

  24. GO 1000 V TC

    6  Pages

  25. P 8000 T TA

    6  Pages

  26. P 500 AC TC

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.