Slip-on Unit with prover

Product catalog summary
Introduction
The document outlines the operating and maintenance instructions for the Seraphin® Slip-On Unit with Prover, a mobile system for calibrating gasoline and diesel fuel dispensers. It includes safety warnings, setup procedures, and maintenance guidelines.
Specifications
The system features three precision volumetric stainless steel bottom drain special J provers, each linked to an 80-gallon holding tank, and a 50-gallon Series J prover for high-speed diesel dispensers. This setup allows for multiple calibration tests before returning fuel to the storage tank.
Setup Procedure
1. Ground the calibration trailer using the provided grounding cable.
2. Remove cotter pins and adjust the provers to be free-standing.
3. Close all drain valves.
4. Inspect the prover for debris.
Prover Wetting Procedure
1. Fill the prover with liquid to its nominal capacity.
2. Drain the prover to wet its internal sides, ensuring consistency in liquid clinging.
Calibration Procedure
1. Fill the prover to its nominal capacity.
2. Level the prover and compare readings on the graduated scale to the meter.
3. Drain the prover and document the readings.
Gravity Draining
1. Ensure the drain valve is closed.
2. Connect the drain hose and route it to the storage tank inlet.
3. Open the gravity drain valve and monitor the hose.
4. Close the valve once drained and ensure all residual fuel is removed.
Proving Run with 50 Gallon Series J Prover
1. Perform the wet down procedure.
2. Record meter readings and ensure proper grounding.
3. Fill and drain the prover, ensuring consistent measurements.
Care and Maintenance
Regularly check for dents and leaks. Use authorized repair parts if needed.
Safety Considerations
Users must establish safety practices and comply with regulatory limitations. Obtain Material Safety Data Sheets for hazardous materials and follow disposal regulations.
References
Refer to NIST Handbook 44 and API Manual of Petroleum Measurement Standards for official procedures.
Specifications and Safety Measures
All automated or power-operated meter proving systems must include emergency manual operators for use during accidents or power failures. Grounding devices are essential to protect against electrical shock or static discharge in both tank provers and electrical instrumentation. All electrical connections must be explosion-proof, and wiring must comply with the National Electrical Code, specifically Articles 300, 500, Group D, Class 1, Division 1, and 250.45.
Warranty Information
Pemberton Fabricators, Inc. provides a warranty ensuring that the product will conform to the description in the quotation. They agree to repair or replace any parts, excluding expendable items like filters and lights, that fail due to defects in material or workmanship within one year of use or 18 months after shipment, whichever comes first. The warranty excludes implied warranties of fitness for a particular purpose and merchantability. Liability is limited to the cost of repair or replacement of defective parts, and Pemberton Fabricators, Inc. is not liable for special, indirect, incidental, or consequential damages. No legal action may be initiated more than one year after the cause of action has accrued.
See more

Catalog excerpts

Slip-on Unit with prover-1

Seraphin - 30 Indel Avenue Ζ Rancocas, NJ 08073 Tel: 1-609-267-0922 Fax: 1-609-261-2546 e-mail: [email protected] Pub E91-4044 >

 Open the catalog to page 1
Slip-on Unit with prover-2

PEMBERTON FABRICATORS, INC. (SERAPHIN > DIVISION) SHALL NOT BE LIABLE FOR TECHNICAL OR EDITORIAL ERRORS IN THIS MANUAL OR OMISSIONS FROM THIS MANUAL. SERAPHIN > ή MAKES NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THIS MANUAL AND, IN NO EVENT, SHALL SERAPHIN > BE LIABLE FOR ANY SPECIAL OR CONSEQUENTIAL DAMAGES INCLUDING, BUT NOT LIMITED TO, LOSS OF PRODUCTION, LOSS OF PROFITS, ETC. PRODUCT NAMES USED HEREIN ARE FOR MANUFACTURER OR SUPPLIER IDENTIFICATION ONLY AND MAYBE TRADEMARKS/REGISTERED TRADEMARKS...

 Open the catalog to page 2
Slip-on Unit with prover-3

3 Description: The Seraphin Slip-on with prover is a mobile proving system designed to calibrate gasoline and diesel fuel dispensers. It is comprised of (3) precision volumetric stainless steel bottom drain special J provers connected each to their own individual 80 gallon SS holding tank witha 50 Gallon Series J prover is installed above the holding tanks for testing high speed diesel dispensers. The 80 gallon configuration allows for up to 48 (5-gallon) or 6 (50 Gallon) calibration tests before returning to the fuel station's storage tank for dumping. The prover drain valve is plumed to piping...

 Open the catalog to page 3
Slip-on Unit with prover-4

4 5.Visually inspect, from the top neck opening, the interior of the prover to ensure it is free of debris which could affect the accuracy of the liquid volume measurement. Prover Wetting Procedure :1.If the prover is clean and free of debris, fill the prover with liquid from the meter device being checked. Fill the prover until the amount on the meter reads the nominal capacity of the prover. NOTE: The prover must be filled once and drained in order to wet the internal sides of the prover body. Wetting the internals of the prover helps ensure consistency in the amount of liquid that clings to...

 Open the catalog to page 4
Slip-on Unit with prover-5

CAUTION: Ensure all fuel residual is drained from the hose into the underground storage tank prior to lifting the hose from the storage tank inlet > CAUTION: Disposal of drained fluid should be done in an environmentally safe and responsible manner in accordance with good industry practices and in compliance with OSHA regulations SeraphinԮ - 30 Indel Avenue Rancocas, NJ 08073 Tel: 1-609-267-0922 Fax: 1-609-261-2546 e-mail: [email protected] Pub E91-4044 >

 Open the catalog to page 5
Slip-on Unit with prover-6

6 8. Stow the drained hose, secure the provers with the (3) locking brackets making sure to replace the cotter pins and replace vapor caps. Conducting a Proving Run with the 50 Gallon Series J Prover: 1. Close the Series J prover drain valve. 2. Perform the wet down procedure on the prover. Prover Wetting Procedure :1.If the prover is clean and free of debris, fill the prover with liquid from the meter device being checked. Fill the prover until the amount on the meter reads the nominal capacity of the prover. NOTE : The prover must be filled once and drained in order to wet the internal sides...

 Open the catalog to page 6
Slip-on Unit with prover-7

CAUTION: Disposal of drained fluid should be done in an environmentally safe and responsible manner in accordance with good industry practices and in compliance with OSHA regulations > CAUTION: Disposal of drained fluid should be done in an environmentally safe and responsible manner in accordance with good industry practices and in compliance with OSHA regulations Seraphin - 30 Indel Avenue Ζ Rancocas, NJ 08073 Tel: 1-609-267-0922 Fax: 1-609-261-2546 e-mail: [email protected] Pub E91-4044 >

 Open the catalog to page 7
Slip-on Unit with prover-8

Reference: For officially recognized petroleum measurement procedures and methodsreference: NIST Handbook 44 Specifications, and Tolerances, and other Technical Requirements for Weighing and Measuring. API Manual of Petroleum Measurement Standards, Chapter 4, Section 4 (Tank Provers) and Section 8 (Operation of Proving Systems). Care and Maintenance of Provers 1. Check provers, valves and piping periodically for dents and leaks at the seams, joints, connections and gauge assembly. If a leak is detected, call SERAPHIN > ׮ for authorized repair parts. > Seraphin - 30 Indel Avenue Ζ Rancocas, NJ...

 Open the catalog to page 8
Slip-on Unit with prover-9

Bottom loading: Method of filling a volumetric vessel. Intake is made with a bottom load adapter. Capacity, nominal : T he nominal capacity of a field standard test measure or prover is the volume used to designate the measure or prover. The volume is determined by the nominal mark on a graduated upper neck gauge and between the nominal mark on the graduated upper neck gauge and the lower shut off valve or zero mark on a lower neck gauge on a prover. > NOTE: The nominal capacity of the prover has be set at the Seraphin facility using Standards that are traceable to the National Institute of Standards...

 Open the catalog to page 9
Slip-on Unit with prover-10

Seraphin - 30 Indel Avenue Ζ Rancocas, NJ 08073 Tel: 1-609-267-0922 Fax: 1-609-261-2546 e-mail: [email protected] Pub E91-4044 >

 Open the catalog to page 10
Slip-on Unit with prover-11

PO BOX 227 30 INDEL AVENUE RANCOCAS, NJ 08073-0227 > PEMBERTON FABRICATORS, INC. FULLY WARRANTS THAT THE PRODUCT SUPPLIED SHALL CONFORM TO THE DESCRIPTION IN THE QUOTATION AND AGREES TO REPAIR OR REPLACE F.O.B. SHIPPING POINTS, ANY PARTS EXCEPTING EXPENDABLE ITEMS SUCH AS FILTERS AND LIGHTS THAT FAIL DUE TO DEFECTS IN MATERIAL OR WORKMANSHIP WITHIN ONE YEAR OF USE OR 18 MONTHS AFTER SHIPMENT, WHICHEVER OCCURS FIRST. Other than those expressively stated herein, there are no other warranties of any kind, expressed or implied, and specifically excluded but not by way of limitation, are the implied...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.